Skip to content
maunawai.info

Drinking water in Weisendorf

One supply zone, water supplier: Erlanger Stadtwerke AG.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
Hardness range 2
Key values Seebachgruppe
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 7 mg/l 50 mg/l
14 %
Mean
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Mean
Sulphate 20 mg/l 250 mg/l
8 %
Mean
Sodium 11 mg/l 200 mg/l
5 %
Mean
Show all recorded parameters (38 — most recent value per parameter)

Microbiology (2)

Microbiology – Seebachgruppe
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Mean
Intestinal enterococci 0 in 100 ml 0/100 ml Mean

Chemical parameters (9)

Chemical parameters – Seebachgruppe
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,00010 mg/l
below limit of quantification
3 µg/l
< 3 % *
Mean
Arsenic <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Mean
Boron <0,04 mg/l
below limit of quantification
1 mg/l
< 4 % *
Mean
Fluoride <0,2 mg/l
below limit of quantification
1.5 mg/l
< 13 % *
Mean
Nitrate 7 mg/l 50 mg/l
14 %
Mean
Nitrite <0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Mean
Pesticides — Total n.n. mg/l
not detectable
0.5 µg/l Mean
Trihalomethanes — Total 0,005 mg/l 50 µg/l
10 %
Mean
Uranium 0,002 mg/l 10 µg/l
20 %
Mean

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (16)

Indicator parameters – Seebachgruppe
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Mean
Ammonium <0,04 mg/l
below limit of quantification
0.5 mg/l
< 8 % *
Mean
Calcite dissolution capacity 0 mg/l CaCO3 5 mg/l CaCO3 Mean
Chloride 15 mg/l 250 mg/l
6 %
Mean
Coliform bacteria 0 in 100 ml 0/100 ml Mean
Colony count 22 °C 0 in 1 ml ohne anormale Veränderung Mean
Colony count 36 °C 0 in 1 ml ohne anormale Veränderung Mean
Conductivity (25 °C) 526 µS/cm 2,790 µS/cm Mean
Iron <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Mean
Manganese <0,01 mg/l
below limit of quantification
50 µg/l
< 20 % *
Mean
pH 7,68 6,5–9,5 Mean
Sodium 11 mg/l 200 mg/l
5 %
Mean
Sulphate 20 mg/l 250 mg/l
8 %
Mean
Temperature 13,3 °C Mean
Total organic carbon (TOC) 0,7 mg/l ohne anormale Veränderung Mean
Turbidity 0,11 FNU 1 NTU Mean

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (11)

Further parameters – Seebachgruppe
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 4,6 mmol/l Mean
Base capacity to pH 8.2 0,27 mmol/l Mean
Calcium 69 mg/l Mean
Carbonate hardness 12,83 °dH Mean
Hardness range (WRMG) 2 Mean
Hydrogen carbonate 280 mg/l Mean
Magnesium 18,8 mg/l Mean
Oxygen 9,6 mg/l Mean
Phosphate 0,31 mg/l Mean
Potassium 2,2 mg/l Mean
Sum of alkaline earth metals 2,48 mmol/l Mean

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.vg-hessdorf.de/wp-content/uploads/2026/05/Trinkwasser-Analysenblatt-Seebach.pdf · 25.07.2025 · Durchschnittswerte 2024 · retrieved on 13/07/2026

Postcodes in this zone: 91085

Frequently asked questions about drinking water in Weisendorf

How hard is the water in Weisendorf?
Erlanger Stadtwerke AG publishes the hardness range 2 for the supply zone Seebachgruppe. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 25.07.2025, retrieved on 13/07/2026.
How much nitrate is in the drinking water in Weisendorf?
Erlanger Stadtwerke AG publishes a nitrate value of 7 mg/l for the supply zone Seebachgruppe. The statutory parametric value is 50 mg/l; the measured value represents 14 % of the parametric value. Basis: 25.07.2025, retrieved on 13/07/2026.
Who supplies the drinking water in Weisendorf?
Erlanger Stadtwerke AG. The values shown here come from the supply zone Seebachgruppe and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.