Skip to content
maunawai.info

Drinking water in Schlüsselfeld

One supply zone, water supplier: Schlüsselfeld (Trinkwasserversorgung Ortsteile Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach).

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
Hardness range 17,2
Key values Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 15 mg/l 50 mg/l
30 %
Single value
Lead <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Escherichia coli (E. coli) 0 KbE/100ml 0/100 ml Single value
Sulphate 43 mg/l 250 mg/l
17 %
Single value
Sodium 34,8 mg/l 200 mg/l
17 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (51 — most recent value per parameter)

Microbiology (2)

Microbiology – Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KbE/100ml 0/100 ml Single value
Intestinal enterococci 0 KbE/100ml 0/100 ml Single value

Chemical parameters (24)

Chemical parameters – Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,5 µg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
Antimony <0,001 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Benzene <0,3 µg/l
below limit of quantification
1 µg/l
< 30 % *
Single value
Benzo(a)pyrene <0,003 µg/l
below limit of quantification
10 ng/l
< 30 % *
Single value
Bisphenol A <0,4 µg/l
below limit of quantification
2.5 µg/l
< 16 % *
Single value
Boron 0,428 mg/l 1 mg/l
43 %
Single value
Bromate <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Cadmium <0,0005 mg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
Chromium <0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value
Copper <0,01 mg/l
below limit of quantification
2 mg/l
< 0.5 % *
Single value
Cyanide <0,002 mg/l
below limit of quantification
50 µg/l
< 4 % *
Single value
Fluoride 0,10 mg/l 1.5 mg/l
7 %
Single value
Lead <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Mercury <0,0002 mg/l
below limit of quantification
1 µg/l
< 20 % *
Single value
Nickel <0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value
Nitrate 15 mg/l 50 mg/l
30 %
Single value
Nitrate/50 + Nitrite/3 0,30 mg/l 1 Single value
Nitrite <0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value
Polycyclic aromatic hydrocarbons <0,01 µg/l
below limit of quantification
0.1 µg/l
< 10 % *
Single value
Selenium <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Tetrachloroethene and Trichloroethene (sum) <1 µg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Trihalomethanes — Total <1 µg/l
below limit of quantification
50 µg/l
< 2 % *
Single value
Uranium 8 µg/l 10 µg/l
80 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (19)

Indicator parameters – Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Ammonium <0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value
Calcite dissolution capacity -19,7 mg/l 5 mg/l CaCO3 Single value
Chloride 19 mg/l 250 mg/l
8 %
Single value
Coliform bacteria 0 KbE/100ml 0/100 ml Single value
Colony count 22 °C 0 KbE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KbE/ml ohne anormale Veränderung Single value
Colour <0,05 1/m
below limit of quantification
0.5 m⁻¹ Single value
Conductivity (25 °C) 700 µS/cm 2,790 µS/cm Single value
Iron <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Odour 100 für den Verbraucher annehmbar Single value
pH 7,6 6,5–9,5 Single value
Sodium 34,8 mg/l 200 mg/l
17 %
Single value
Sulphate 43 mg/l 250 mg/l
17 %
Single value
Taste 100 für den Verbraucher annehmbar Single value
Temperature 16,3 °C Single value
Total organic carbon (TOC) 0,92 mg/l ohne anormale Veränderung Single value
Turbidity 0,11 TE/F 1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (6)

Further parameters – Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 6,03 mmol/l Single value
Calcium 64,2 mg/l Single value
Hardness range (WRMG) 17,2 °dH Single value
Magnesium 35,8 mg/l Single value
Potassium 3,88 mg/l Single value
Saturation index 0,279 Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 96132

Frequently asked questions about drinking water in Schlüsselfeld

How hard is the water in Schlüsselfeld?
Schlüsselfeld (Trinkwasserversorgung Ortsteile Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach) publishes the hardness range 17,2 for the supply zone Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 08/08/2026.
How much nitrate is in the drinking water in Schlüsselfeld?
Schlüsselfeld (Trinkwasserversorgung Ortsteile Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach) publishes a nitrate value of 15 mg/l for the supply zone Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach. The statutory parametric value is 50 mg/l; the measured value represents 30 % of the parametric value. Basis: Publication by the water supplier, retrieved on 08/08/2026.
Who supplies the drinking water in Schlüsselfeld?
Schlüsselfeld (Trinkwasserversorgung Ortsteile Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach). The values shown here come from the supply zone Reichmannsdorf, Eckersbach, Elsendorf, Possenfelden, Güntersdorf, Lach and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.