Skip to content
maunawai.info

Drinking water in Passau

One supply zone, water supplier: Stadtwerke Passau GmbH.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Insel Soldatenau

Stadtwerke Passau GmbH

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values Insel Soldatenau
Parameter Value Parametric value Share of the parametric value Reference
Sum of PFAS 0,0054 Single value
Nitrate 5,4
Unit not stated in the document
50 mg/l Single value
Sulphate 29,3
Unit not stated in the document
250 mg/l Single value
Sodium 11,2
Unit not stated in the document
200 mg/l Single value
Show all recorded parameters (48 — most recent value per parameter)

Chemical parameters (9)

Chemical parameters – Insel Soldatenau
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0.3
below limit of quantification
Unit not stated in the document
3 µg/l Single value
Acrylamide < 0.025
below limit of quantification
Unit not stated in the document
0.1 µg/l Single value
Benzene < 0.50
below limit of quantification
Unit not stated in the document
1 µg/l Single value
Boron 0,01
Unit not stated in the document
1 mg/l Single value
Bromate < 0.0025
below limit of quantification
Unit not stated in the document
10 µg/l Single value
Chromium < 0.0005
below limit of quantification
Unit not stated in the document
25 µg/l Single value
Cyanide < 0.0050
below limit of quantification
Unit not stated in the document
50 µg/l Single value
Nitrate 5,4
Unit not stated in the document
50 mg/l Single value
Nitrite < 0.01
below limit of quantification
Unit not stated in the document
0.5 mg/l Single value

PFAS (16)

PFAS – Insel Soldatenau
Parameter Value Parametric value Share of the parametric value Reference
Perfluorobutane sulfonic acid (PFBS) < 0.0010
below limit of quantification
Single value
Perfluorobutanoic acid (PFBA) 0,0014 Single value
Perfluorodecane sulfonic acid (PFDS) < 0.0010
below limit of quantification
Single value
Perfluorodecanoic acid (PFDA) < 0.0010
below limit of quantification
Single value
Perfluoroheptane sulfonic acid (PFHpS) < 0.0010
below limit of quantification
Single value
Perfluoroheptanoic acid (PFHpA) < 0.0010
below limit of quantification
Single value
Perfluorohexane sulfonic acid (PFHxS) < 0.0010
below limit of quantification
Single value
Perfluorohexanoic acid (PFHxA) <0,0010
below limit of quantification
Single value
Perfluorononane sulfonic acid (PFNS) < 0.0010
below limit of quantification
Single value
Perfluorononanoic acid (PFNA) < 0.0010
below limit of quantification
Single value
Perfluorooctanesulfonic acid (PFOS) < 0.0010
below limit of quantification
Single value
Perfluorooctanoic acid (PFOA) 0,0015 Single value
Perfluoropentanesulfonic acid (PFPeS) < 0.0010
below limit of quantification
Single value
Perfluoropentanoic acid (PFPeA) 0,0015 Single value
Perfluorotridecanoic acid (PFTrDA) < 0.0010
below limit of quantification
Single value
Sum of PFAS 0,0054 Single value

Indicator parameters (14)

Indicator parameters – Insel Soldatenau
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0.0050
below limit of quantification
Unit not stated in the document
0.2 mg/l Single value
Ammonium 0.01
Unit not stated in the document
0.5 mg/l Single value
Calcite dissolution capacity -1
Unit not stated in the document
5 mg/l CaCO3 Single value
Chloride 21,5
Unit not stated in the document
250 mg/l Single value
Colour farblos
Unit not stated in the document
0.5 m⁻¹ Single value
Iron < 0.010
below limit of quantification
Unit not stated in the document
0.2 mg/l Single value
Manganese < 0.0050
below limit of quantification
Unit not stated in the document
50 µg/l Single value
Odour o.B. für den Verbraucher annehmbar Single value
pH 7.58 bei 14,1 øC 6,5–9,5 Single value
Sodium 11,2
Unit not stated in the document
200 mg/l Single value
Sulphate 29,3
Unit not stated in the document
250 mg/l Single value
Temperature 13,9 Single value
Total organic carbon (TOC) 0,68 ohne anormale Veränderung Single value
Turbidity 0,11
Unit not stated in the document
1 NTU Single value

Further parameters (9)

Further parameters – Insel Soldatenau
Parameter Value Parametric value Share of the parametric value Reference
Calcium 58,9 Single value
Carbonate hardness 9,2 Single value
Dissolved organic carbon (DOC) 0,62 Single value
Free carbon dioxide 9,0 Single value
Magnesium 13,5 Single value
Potassium 2,3 Single value
Saturation index +0,02 Single value
Sum of alkaline earth metals 2,0 Single value
Total hardness 11,4 Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 94032 , 94034 , 94036

Frequently asked questions about drinking water in Passau

Who supplies the drinking water in Passau?
Stadtwerke Passau GmbH. The values shown here come from the supply zone Insel Soldatenau and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.