Skip to content
maunawai.info

Drinking water in Oerlinghausen

One supply zone, water supplier: Stadtwerke Oerlinghausen.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Oerlinghausen/Währentrup/Oetenhausen/Querriegel

Stadtwerke Oerlinghausen

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 18 mg/l 50 mg/l
36 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Sulphate 28 mg/l 250 mg/l
11 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Sodium 15,2 mg/l 200 mg/l
8 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (37 — most recent value per parameter)

Microbiology (2)

Microbiology – Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Intestinal enterococci 0 in 100 ml 0/100 ml Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel

Chemical parameters (10)

Chemical parameters – Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Parameter Value Parametric value Share of the parametric value Reference
Antimony < 0,0005 mg/l
below limit of quantification
5 µg/l
< 10 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Arsenic < 0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Benzo(a)pyrene < 0,000003 mg/l
below limit of quantification
10 ng/l
< 30 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Cadmium < 0,001 mg/l
below limit of quantification
3 µg/l
< 33 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Copper 0,08 mg/l 2 mg/l
4 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Nickel 0,001 mg/l 20 µg/l
5 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Nitrate 18 mg/l 50 mg/l
36 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Nitrite < 0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Trihalomethanes — Total < 0,004 mg/l
below limit of quantification
50 µg/l
< 8 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (18)

Indicator parameters – Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Parameter Value Parametric value Share of the parametric value Reference
Aluminium 0,01 mg/l 0.2 mg/l
5 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Ammonium < 0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Calcite dissolution capacity 15 mg/l 5 mg/l CaCO3 Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Chloride 26 mg/l 250 mg/l
10 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Coliform bacteria 0 in 100 ml 0/100 ml Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Colony count 22 °C 0 in 1 ml ohne anormale Veränderung Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Colony count 36 °C 0 in 1 ml ohne anormale Veränderung Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Colour < 0,1 1/m
below limit of quantification
0.5 m⁻¹ Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Iron 0,01 mg/l 0.2 mg/l
5 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Manganese < 0,01 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Odour ohne für den Verbraucher annehmbar Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
pH 7,09 6,5–9,5 Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Sodium 15,2 mg/l 200 mg/l
8 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Sulphate 28 mg/l 250 mg/l
11 %
Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Taste ohne für den Verbraucher annehmbar Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Temperature 15,6 °C Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Total organic carbon (TOC) < 0,5 mg/l
below limit of quantification
ohne anormale Veränderung Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Turbidity 0,02 FNU 1 NTU Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,00 mmol/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Base capacity to pH 8.2 0,31 mmol/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Calcium 53,1 mg/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Carbonate hardness 5,6 °dH Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Hydrogen carbonate 144,0 mg/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Magnesium 5,3 mg/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel
Potassium 1,6 mg/l Single value · Oerlinghausen/Währentrup/Oetenhausen/Querriegel

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 33813

Frequently asked questions about drinking water in Oerlinghausen

How much nitrate is in the drinking water in Oerlinghausen?
Stadtwerke Oerlinghausen publishes a nitrate value of 18 mg/l for the supply zone Oerlinghausen/Währentrup/Oetenhausen/Querriegel. The statutory parametric value is 50 mg/l; the measured value represents 36 % of the parametric value. Basis: 17.09.2025, retrieved on 11/07/2026.
Who supplies the drinking water in Oerlinghausen?
Stadtwerke Oerlinghausen. The values shown here come from the supply zone Oerlinghausen/Währentrup/Oetenhausen/Querriegel and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.