Drinking water in Oberwil-Lieli
One supply zone, water supplier: Gemeinde Oberwil-Lieli.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Oberwil-Lieli
Gemeinde Oberwil-LieliAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 18.3 mg/l | 40 mg/l | 46 % | Mean · Oberwil-Lieli |
| Sulphate | 11.8 mg/l | — | — | Mean · Oberwil-Lieli |
| Sodium | 7 mg/l | 200 mg/l | 3 % | Mean · Oberwil-Lieli |
Show all recorded parameters (12 — most recent value per parameter)
Microbiology (1)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aerobic mesophilic bacteria | 3 KBE/ml | 300 1/ml | — | Mean · Oberwil-Lieli |
Chemical parameters (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Fluoride | < 0.1 mg/l below limit of quantification | 1.5 mg/l | < 7 % * | Mean · Oberwil-Lieli |
| Nitrate | 18.3 mg/l | 40 mg/l | 46 % | Mean · Oberwil-Lieli |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (4)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Chloride | 10.2 mg/l | — | — | Mean · Oberwil-Lieli |
| Sodium | 7 mg/l | 200 mg/l | 3 % | Mean · Oberwil-Lieli |
| Sulphate | 11.8 mg/l | — | — | Mean · Oberwil-Lieli |
| Temperature | 11.6 °C | — | — | Mean · Oberwil-Lieli |
Further parameters (5)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Calcium | 122.5 mg/l | — | — | Mean · Oberwil-Lieli |
| Dissolved organic carbon (DOC) | 0.51 mg/l | — | — | Mean · Oberwil-Lieli |
| Magnesium | 26.3 mg/l | — | — | Mean · Oberwil-Lieli |
| Potassium | 1.4 mg/l | — | — | Mean · Oberwil-Lieli |
| Total hardness | 39.2 °fH | — | — | Mean · Oberwil-Lieli |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 8966
Frequently asked questions about drinking water in Oberwil-Lieli
- How hard is the water in Oberwil-Lieli?
- Gemeinde Oberwil-Lieli publishes a total hardness of 39.2 °fH for the supply zone Oberwil-Lieli — that corresponds to 22 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2025, retrieved on 07/08/2026.
- How much nitrate is in the drinking water in Oberwil-Lieli?
- Gemeinde Oberwil-Lieli publishes a nitrate value of 18.3 mg/l for the supply zone Oberwil-Lieli. The statutory parametric value is 40 mg/l; the measured value represents 46 % of the parametric value. Basis: 2025, retrieved on 07/08/2026.
- Who supplies the drinking water in Oberwil-Lieli?
- Gemeinde Oberwil-Lieli. The values shown here come from the supply zone Oberwil-Lieli and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.