Skip to content
maunawai.info

Drinking water in Nettelsee

One supply zone, water supplier: Wasserversorgung Preetz-West (ZWV Preetz-West).

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

ZWV Preetz-West / Netzprobe Klein-Barkau

Wasserversorgung Preetz-West (ZWV Preetz-West)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values ZWV Preetz-West / Netzprobe Klein-Barkau
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Show all recorded parameters (9 — most recent value per parameter)

Microbiology (2)

Microbiology – ZWV Preetz-West / Netzprobe Klein-Barkau
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Indicator parameters (7)

Indicator parameters – ZWV Preetz-West / Netzprobe Klein-Barkau
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Conductivity (25 °C) 569 µS/cm 2,790 µS/cm Single value
pH 7,89 6,5–9,5 Single value
Temperature 19,2 °C Single value
Turbidity 0,05 NTU 1 NTU Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.amtpreetzland.de/fileadmin/Amt/Dateien/Wasserversorgung_Analyseergebnisse/Preetz-West.pdf · 06.07.2026 · 2. Quartal 2026 · retrieved on 14/07/2026

Postcodes in this zone: 24250

Frequently asked questions about drinking water in Nettelsee

Who supplies the drinking water in Nettelsee?
Wasserversorgung Preetz-West (ZWV Preetz-West). The values shown here come from the supply zone ZWV Preetz-West / Netzprobe Klein-Barkau and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.