Skip to content
maunawai.info

Drinking water in Michendorf

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

WAZV Mittelgraben (Wasser- und Abwasserzweckverband Mittelgraben)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

No date is given for these values. The water supplier publishes the analysis without a sampling date and without a report date. When the water was examined is not apparent from the source — we do not add a date and we do not estimate one. What is stated is therefore only when we retrieved the document.

Water hardness
14.5 °dH
Hardness range hard
Key values Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 2 mg/l 50 mg/l
4 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Lead < 1,0 µg/l
below limit of quantification
10 µg/l
< 10 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Escherichia coli (E. coli) 0 0/100 ml 0/100 ml Maximum · Median 0 · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Sulphate 90 mg/l 250 mg/l
36 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Sodium 38 mg/l 200 mg/l
19 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (31 — most recent value per parameter)

Microbiology (1)

Microbiology – Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 0/100 ml 0/100 ml Maximum · Median 0 · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

Chemical parameters (12)

Chemical parameters – Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Parameter Value Parametric value Share of the parametric value Reference
Arsenic < 2,0 µg/l
below limit of quantification
10 µg/l
< 20 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Boron < 0,1 mg/l
below limit of quantification
1 mg/l
< 10 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Cadmium < 0,5 µg/l
below limit of quantification
3 µg/l
< 17 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Copper < 5,0 µg/l
below limit of quantification
2 mg/l
< 0.3 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Fluoride 0,1 mg/l 1.5 mg/l
7 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Lead < 1,0 µg/l
below limit of quantification
10 µg/l
< 10 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Mercury < 0,1 µg/l
below limit of quantification
1 µg/l
< 10 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Nickel < 5.0 µg/l
below limit of quantification
20 µg/l
< 25 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Nitrate 2 mg/l 50 mg/l
4 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Nitrite < 0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Polycyclic aromatic hydrocarbons < 0,1 µg/l
below limit of quantification
0.1 µg/l
< 100 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Uranium < 0,1 µg/l
below limit of quantification
10 µg/l
< 1 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (11)

Indicator parameters – Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,05 mg/l
below limit of quantification
0.2 mg/l
< 25 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Ammonium < 0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Chloride 54 mg/l 250 mg/l
22 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Coliform bacteria 0 0/100 ml 0/100 ml Maximum · Median 0 · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Conductivity (25 °C) 660 µs/cm 2,790 µS/cm Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Iron 0,01 mg/l 0.2 mg/l
5 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Manganese 0,01 mg/l 50 µg/l
20 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
pH 7,8 6,5–9,5 Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Sodium 38 mg/l 200 mg/l
19 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Sulphate 90 mg/l 250 mg/l
36 %
Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Total organic carbon (TOC) < 1,7 mg C/l
below limit of quantification
ohne anormale Veränderung Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Parameter Value Parametric value Share of the parametric value Reference
Calcium 100 mg/l Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Carbonate hardness 7,3 °dH Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Hydrogen carbonate 210 mg/l Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Magnesium 9 mg/l Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Potassium 4 mg/l Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Saturation index 0,3 Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf
Total hardness 14,5 °dH Mean · Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 14552

Show 1 more supply zone

Michendorf (Wasserwerk Am Berg und Bergheide)

WAZV Mittelgraben (Wasser- und Abwasserzweckverband Mittelgraben)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2019. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
11.2 °dH
Hardness range mittel
Key values Michendorf (Wasserwerk Am Berg und Bergheide)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 1,0 mg/L 50 mg/l
2 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Lead 0,00062 mg/L 10 µg/l
6 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Escherichia coli (E. coli) 0 je 100 mL 0/100 ml Maximum · Median 0 · Michendorf (Wasserwerk Am Berg und Bergheide)
Sulphate 49 mg/L 250 mg/l
20 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Sodium 11,4 mg/L 200 mg/l
6 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Show all recorded parameters (41 — most recent value per parameter)

Microbiology (2)

Microbiology – Michendorf (Wasserwerk Am Berg und Bergheide)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 je 100 mL 0/100 ml Maximum · Median 0 · Michendorf (Wasserwerk Am Berg und Bergheide)
Intestinal enterococci 0 je 100 mL 0/100 ml Maximum · Median 0 · Michendorf (Wasserwerk Am Berg und Bergheide)

Chemical parameters (14)

Chemical parameters – Michendorf (Wasserwerk Am Berg und Bergheide)
Parameter Value Parametric value Share of the parametric value Reference
Arsenic 0,000 mg/L 10 µg/l
0 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Bisphenol A n. n. mg/L
not detectable
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Boron 0,03 mg/L 1 mg/l
3 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Cadmium 0,00010 mg/L 3 µg/l
3 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Copper 0,07162 mg/L 2 mg/l
4 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Cyanide 0,002 mg/L 50 µg/l
4 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Fluoride 0,18 mg/L 1.5 mg/l
12 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Lead 0,00062 mg/L 10 µg/l
6 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Mercury 0,00004 mg/L 1 µg/l
4 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Nickel 0,00081 mg/L 20 µg/l
4 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Nitrate 1,0 mg/L 50 mg/l
2 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Nitrite 0,04 mg/L 0.5 mg/l
8 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Polycyclic aromatic hydrocarbons 0,00001 mg/L 0.1 µg/l
10 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Uranium 0,00004 mg/L 10 µg/l
0.4 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)

Indicator parameters (14)

Indicator parameters – Michendorf (Wasserwerk Am Berg und Bergheide)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium 0,01 mg/L 0.2 mg/l
5 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Ammonium 0,029 mg/L 0.5 mg/l
6 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Calcite dissolution capacity -5,29 mg/L 5 mg/l CaCO3 Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Chloride 18,4 mg/L 250 mg/l
7 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Coliform bacteria 0 je 100 mL 0/100 ml Maximum · Median 0 · Michendorf (Wasserwerk Am Berg und Bergheide)
Colour 0,19 1/m 0.5 m⁻¹ Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Iron 0,01 mg/L 0.2 mg/l
5 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Manganese 0,005 mg/L 50 µg/l
10 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
pH 7,53 6,5–9,5 Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Sodium 11,4 mg/L 200 mg/l
6 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Sulphate 49 mg/L 250 mg/l
20 %
Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Temperature 13,5 °C Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Total organic carbon (TOC) 0,97 mg C/L ohne anormale Veränderung Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Turbidity 0,16 NTU 1 NTU Mean · Michendorf (Wasserwerk Am Berg und Bergheide)

Further parameters (11)

Further parameters – Michendorf (Wasserwerk Am Berg und Bergheide)
Parameter Value Parametric value Share of the parametric value Reference
Calcium 1,74 mmol/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Carbonate hardness 7,9 °dH Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Dissolved organic carbon (DOC) 0,92 mg C/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Hardness range (WRMG) mittel Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Hydrogen carbonate 179 mg/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Magnesium 0,24 mmol/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Non-carbonate hardness 3,2 °dH Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Oxygen 5,6 mg/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Potassium 0,03 mmol/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Saturation index 0,23 Mean · Michendorf (Wasserwerk Am Berg und Bergheide)
Total hardness 1,99 mmol/L Mean · Michendorf (Wasserwerk Am Berg und Bergheide)

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.wazv-mittelgraben.de/trinkwasser/trinkwasserqualitaet/ · 09.01.2026 · seit 2019 (Jahreswerte; Min/Max = Minimal-/Maximalkonzentration seit 2019, Mittel = arithmetisches Mittel der Jahreswerte seit 2019) · retrieved on 13/07/2026

Postcodes in this zone: 14552

Frequently asked questions about drinking water in Michendorf

How hard is the water in Michendorf?
WAZV Mittelgraben (Wasser- und Abwasserzweckverband Mittelgraben) publishes a total hardness of 14.5 °dH for the supply zone Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf (hardness range hard). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Michendorf?
WAZV Mittelgraben (Wasser- und Abwasserzweckverband Mittelgraben) publishes a nitrate value of 2 mg/l for the supply zone Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf. The statutory parametric value is 50 mg/l; the measured value represents 4 % of the parametric value. Basis: Publication by the water supplier, retrieved on 11/07/2026.
Who supplies the drinking water in Michendorf?
WAZV Mittelgraben (Wasser- und Abwasserzweckverband Mittelgraben). The values shown here come from the supply zone Michendorf/Langerwisch/Stücken; Wilhelmshorst/Wildenbruch/Fresdorf and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.