Skip to content
maunawai.info

Drinking water in Leitzersdorf, Stockerau, Niederhollabrunn

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

WVA-Stockerau, Ortsnetz Stockerau Zentral

WVA-Stockerau (Wasserverband/-versorgung Stockerau)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 21/02/2011. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
25.2 °dH
Hardness range hard
Key values WVA-Stockerau, Ortsnetz Stockerau Zentral
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 14,5 mg/l 50 mg/l
29 %
Single value
Lead <4,00 µg/l
below limit of quantification
10 µg/l
< 40 % *
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 72,5 mg/l 250 mg/l
29 %
Single value
Sodium 20,2 mg/l 200 mg/l
10 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (41 — most recent value per parameter)

Microbiology (2)

Microbiology – WVA-Stockerau, Ortsnetz Stockerau Zentral
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (17)

Chemical parameters – WVA-Stockerau, Ortsnetz Stockerau Zentral
Parameter Value Parametric value Share of the parametric value Reference
1,1,1-Trichloroethane <0,5 µg/l
below limit of quantification
Single value
1,2-dichloroethane <0,5 µg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
Bromodichloromethane <0,5 µg/l
below limit of quantification
Single value
Chromium <5,00 µg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Copper <0,02 mg/l
below limit of quantification
2 mg/l
< 1 % *
Single value
Dibromochloromethane <0,5 µg/l
below limit of quantification
Single value
Dichloromethane <1,0 µg/l
below limit of quantification
Single value
Lead <4,00 µg/l
below limit of quantification
10 µg/l
< 40 % *
Single value
Nickel <10,0 µg/l
below limit of quantification
20 µg/l
< 50 % *
Single value
Nitrate 14,5 mg/l 50 mg/l
29 %
Single value
Nitrite <0,01 mg/l
below limit of quantification
0.1 mg/l
< 10 % *
Single value
Tetrachloroethene <0,5 µg/l
below limit of quantification
Single value
Tetrachloroethene and Trichloroethene (sum) 0,0 µg/l 10 µg/l
0 %
Single value
Tetrachloromethane <1,0 µg/l
below limit of quantification
Single value
Tribromomethane (bromoform) <1,0 µg/l
below limit of quantification
Single value
Trichloroethene <0,5 µg/l
below limit of quantification
Single value
Trichloromethane (chloroform) <0,5 µg/l
below limit of quantification
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (15)

Indicator parameters – WVA-Stockerau, Ortsnetz Stockerau Zentral
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Chloride 56,9 mg/l 200 mg/l
28 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml 100 1/ml Single value
Colony count 36 °C 0 KBE/ml 20 1/ml Single value
Conductivity (25 °C) 835 ± 13 µS/cm 2,500 µS/cm Single value
Iron <0,030 mg/l
below limit of quantification
0.2 mg/l
< 15 % *
Single value
Manganese <0,010 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value
Odour nicht auffallend Single value
pH 7,6 ± 0,1 6,5–9,5 Single value
Sodium 20,2 mg/l 200 mg/l
10 %
Single value
Sulphate 72,5 mg/l 250 mg/l
29 %
Single value
Taste nicht auffallend Single value
Temperature 6,8 grd C Single value
Total organic carbon (TOC) 1,4 mg/l Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – WVA-Stockerau, Ortsnetz Stockerau Zentral
Parameter Value Parametric value Share of the parametric value Reference
1,1-Dichloroethene <0,3 µg/l
below limit of quantification
Single value
Calcium 116,2 mg/l 400 mg/l
29 %
Single value
Carbonate hardness 18,6 ± 0,9 °dH Single value
Hydrogen carbonate 406 ± 20 mg/l Single value
Magnesium 39,4 mg/l 150 mg/l
26 %
Single value
Potassium 3,7 mg/l 50 mg/l
7 %
Single value
Total hardness 25,2 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.stockerau.at/system/web/GetDocument.ashx?cts=1740958708&fileId=1343205 · Untersuchung von-bis: 01.02.2011 - 21.02.2011 · retrieved on 14/08/2026

Postcodes in this zone: 2003

Show 1 more supply zone

WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)

WVA-Stockerau (Wasserverband/-versorgung Stockerau)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 24/08/2011. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
26.6 °dH
Hardness range hard
Key values WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 17,8 mg/l 50 mg/l
36 %
Single value · Source [1]
Lead <4,00 µg/l
below limit of quantification
10 µg/l
< 40 % *
Single value · Source [2]
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · Source [1]
Sulphate 75,3 mg/l 250 mg/l
30 %
Single value · Source [1]
Sodium 26,0 mg/l 200 mg/l
13 %
Single value · Source [1]

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (43 — most recent value per parameter)

Microbiology (2)

Microbiology – WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · Source [1]
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value · Source [1]

Chemical parameters (17)

Chemical parameters – WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
1,1,1-Trichloroethane <0,2 µg/l
below limit of quantification
Single value · Source [2]
1,2-dichloroethane <0,2 µg/l
below limit of quantification
3 µg/l
< 7 % *
Single value · Source [2]
Bromodichloromethane <0,2 µg/l
below limit of quantification
Single value · Source [2]
Chromium <5,00 µg/l
below limit of quantification
50 µg/l
< 10 % *
Single value · Source [2]
Copper <0,02 mg/l
below limit of quantification
2 mg/l
< 1 % *
Single value · Source [2]
Dibromochloromethane <0,2 µg/l
below limit of quantification
Single value · Source [2]
Dichloromethane <0,2 µg/l
below limit of quantification
Single value · Source [2]
Lead <4,00 µg/l
below limit of quantification
10 µg/l
< 40 % *
Single value · Source [2]
Nickel <10,0 µg/l
below limit of quantification
20 µg/l
< 50 % *
Single value · Source [2]
Nitrate 17,8 mg/l 50 mg/l
36 %
Single value · Source [1]
Nitrite <0,01 mg/l
below limit of quantification
0.1 mg/l
< 10 % *
Single value · Source [1]
Tetrachloroethene 0,6 µg/l Single value · Source [2]
Tetrachloroethene and Trichloroethene (sum) 0,6 µg/l 10 µg/l
6 %
Single value · Source [2]
Tetrachloromethane <0,2 µg/l
below limit of quantification
Single value · Source [2]
Tribromomethane (bromoform) <1,0 µg/l
below limit of quantification
Single value · Source [2]
Trichloroethene <0,4 µg/l
below limit of quantification
Single value · Source [2]
Trichloromethane (chloroform) <0,2 µg/l
below limit of quantification
Single value · Source [2]

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (15)

Indicator parameters – WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value · Source [1]
Chloride 66,8 mg/l 200 mg/l
33 %
Single value · Source [1]
Coliform bacteria 0 KBE/100ml 0/100 ml Single value · Source [1]
Colony count 22 °C 0 KBE/ml 100 1/ml Single value · Source [1]
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · Source [1]
Conductivity (25 °C) 880 ± 14 µS/cm 2,500 µS/cm Single value · Source [1]
Iron <0,030 mg/l
below limit of quantification
0.2 mg/l
< 15 % *
Single value · Source [1]
Manganese <0,010 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value · Source [1]
Odour nicht auffallend Single value · Source [1]
pH 7,4 ± 0,1 6,5–9,5 Single value · Source [1]
Sodium 26,0 mg/l 200 mg/l
13 %
Single value · Source [1]
Sulphate 75,3 mg/l 250 mg/l
30 %
Single value · Source [1]
Taste nicht auffallend Single value · Source [1]
Temperature 17,8 grd C Single value · Source [1]
Total organic carbon (TOC) 1,1 mg/l Single value · Source [1]

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Radiology (2)

Radiology – WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
Indicative dose 0,007 mSv/Jahr Single value · Source [2]
Tritium <3,2 Bq/l
below limit of quantification
Single value · Source [2]

Further parameters (7)

Further parameters – WVA-Stockerau / Ortsnetz Stockerau Zentral (Probestellen-Nr. 004)
Parameter Value Parametric value Share of the parametric value Reference
1,1-Dichloroethene <0,2 µg/l
below limit of quantification
Single value · Source [2]
Calcium 121,0 mg/l 400 mg/l
30 %
Single value · Source [1]
Carbonate hardness 19,4 ± 1,0 °dH Single value · Source [1]
Hydrogen carbonate 422 ± 21 mg/l Single value · Source [1]
Magnesium 42,5 mg/l 150 mg/l
28 %
Single value · Source [1]
Potassium 4,8 mg/l 50 mg/l
10 %
Single value · Source [1]
Total hardness 26,6 °dH Single value · Source [1]

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Sources: [1] https://www.stockerau.at/system/web/GetDocument.ashx?cts=1740958794&fileId=1698958 · Probenahme 02.08.2011; Untersuchung von 03.08.2011 bis 24.08.2011 · retrieved on 14/08/2026 [2] https://www.stockerau.at/system/web/GetDocument.ashx?cts=1740958713&fileId=1343222 · Untersuchung von-bis: 03.05.2011 - 17.06.2011 · retrieved on 14/08/2026

Postcodes in this zone: 2003

Frequently asked questions about drinking water in Leitzersdorf, Stockerau, Niederhollabrunn

How hard is the water in Leitzersdorf, Stockerau, Niederhollabrunn?
WVA-Stockerau (Wasserverband/-versorgung Stockerau) publishes a total hardness of 25.2 °dH for the supply zone WVA-Stockerau, Ortsnetz Stockerau Zentral (hardness range hard). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 14/08/2026.
How much nitrate is in the drinking water in Leitzersdorf, Stockerau, Niederhollabrunn?
WVA-Stockerau (Wasserverband/-versorgung Stockerau) publishes a nitrate value of 14,5 mg/l for the supply zone WVA-Stockerau, Ortsnetz Stockerau Zentral. The statutory parametric value is 50 mg/l; the measured value represents 29 % of the parametric value. Basis: Publication by the water supplier, retrieved on 14/08/2026.
Who supplies the drinking water in Leitzersdorf, Stockerau, Niederhollabrunn?
WVA-Stockerau (Wasserverband/-versorgung Stockerau). The values shown here come from the supply zone WVA-Stockerau, Ortsnetz Stockerau Zentral and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.