Skip to content
maunawai.info

Drinking water in Langenstein, Mauthausen

3 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

Wasserversorgung Rheinfelden

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
14.2 °dH
Hardness range hard
Key values Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 9 mg/l 40 mg/l
23 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Sulphate 31.7 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Sodium 10.5 mg/l 200 mg/l
5 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Show all recorded parameters (24 — most recent value per parameter)

Microbiology (3)

Microbiology – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 1.4 KBE/ml 300 1/ml Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Intestinal enterococci nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

Chemical parameters (2)

Chemical parameters – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Fluoride 1.3 mg/l 1.5 mg/l
87 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Nitrate 9 mg/l 40 mg/l
23 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

PFAS (3)

PFAS – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Perfluorohexane sulfonic acid (PFHxS) < 0.001 µg/l
below limit of quantification
0.3 µg/l
< 0.3 % *
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Perfluorooctanesulfonic acid (PFOS) 0.002 µg/l 0.3 µg/l
0.7 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Perfluorooctanoic acid (PFOA) < 0.001 µg/l
below limit of quantification
0.5 µg/l
< 0.2 % *
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Metabolites (2)

Metabolites – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Chlorothalonil metabolite R417888 < 0.02 µg/l
below limit of quantification
0.1 µg/l
< 20 % *
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Chlorothalonil metabolite R471811 0.052 µg/l 0.1 µg/l
52 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (7)

Indicator parameters – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Chloride 13.5 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Conductivity (25 °C) 508 µS/cm Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
pH 7.5 Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Sodium 10.5 mg/l 200 mg/l
5 %
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Sulphate 31.7 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Temperature 12.2 °C Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Turbidity < 0.2 TE/F
below limit of quantification
Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

Further parameters (7)

Further parameters – Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Parameter Value Parametric value Share of the parametric value Reference
Calcium 78 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Dissolved organic carbon (DOC) 0.4 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Dry residue 0 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Hydrogen carbonate 263 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Magnesium 14 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Potassium 1 mg/l Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden
Total hardness 25.3 °fH Mean · Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 4310

Show 2 more supply zones

Wasserverband Untere Gusen - Hauptstraße 6, EG, Hauswirtschaftsraum, Waschbecken (Probe 25160446-002)

Wasserverband Untere Gusen

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values Wasserverband Untere Gusen - Hauptstraße 6, EG, Hauswirtschaftsraum, Waschbecken (Probe 25160446-002)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Show all recorded parameters (7 — most recent value per parameter)

Microbiology (2)

Microbiology – Wasserverband Untere Gusen - Hauptstraße 6, EG, Hauswirtschaftsraum, Waschbecken (Probe 25160446-002)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Indicator parameters (5)

Indicator parameters – Wasserverband Untere Gusen - Hauptstraße 6, EG, Hauswirtschaftsraum, Waschbecken (Probe 25160446-002)
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 3 KBE/ml 100 1/ml Single value
Colony count 36 °C 3 KBE/ml 20 1/ml Single value
Conductivity (25 °C) 616 µS/cm 2,500 µS/cm Single value
Temperature 11,8 grd C Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.langenstein.at/system/web/getDocument.ashx?cts=1765287710&fileid=4143311 · 02.12.2025 · Probenahme 26.11.2025, Untersuchung 27.11.2025 - 02.12.2025 · retrieved on 14/08/2026

Postcodes in this zone: 4310

WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1

WV der Marktgemeinde Mauthausen

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
24.3 °dH
Hardness range hard
Key values WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 12 mg/l 50 mg/l
24 %
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 37 mg/l 250 mg/l
15 %
Single value
Sodium 29,4 mg/l 200 mg/l
15 %
Single value
Show all recorded parameters (25 — most recent value per parameter)

Microbiology (2)

Microbiology – WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (2)

Chemical parameters – WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 12 mg/l 50 mg/l
24 %
Single value
Nitrite 0,026 mg/l 0.1 mg/l
26 %
Single value

Indicator parameters (15)

Indicator parameters – WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0,040 mg/l
below limit of quantification
0.5 mg/l
< 8 % *
Single value
Chloride 51 mg/l 200 mg/l
26 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 18 KBE/ml 100 1/ml Single value
Colony count 36 °C 0 KBE/ml 20 1/ml Single value
Colour farblos, klar Single value
Conductivity (25 °C) 819 µS/cm 2,500 µS/cm Single value
Iron <0,0300 mg/l
below limit of quantification
0.2 mg/l
< 15 % *
Single value
Manganese <0,0100 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value
Odour ohne Besonderheiten Single value
pH 6,97 6,5–9,5 Single value
Sodium 29,4 mg/l 200 mg/l
15 %
Single value
Sulphate 37 mg/l 250 mg/l
15 %
Single value
Temperature 11,5 grd C Single value
Total organic carbon (TOC) 1,4 mg/l Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (6)

Further parameters – WV der Marktgemeinde Mauthausen, Probehahn Brunnen 1
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 7,6 mmol/l Single value
Calcium 126 mg/l 400 mg/l
32 %
Single value
Carbonate hardness 21,3 °dH Single value
Magnesium 28,8 mg/l 150 mg/l
19 %
Single value
Potassium 5,2 mg/l 50 mg/l
10 %
Single value
Total hardness 24,3 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.mauthausen.at/system/web/getDocument.ashx?cts=1762851658&fileid=4116647 · 29.10.2025 · Probenahme 21.10.2025, Untersuchung 22.10.2025-29.10.2025 · retrieved on 14/08/2026

Postcodes in this zone: 4310

Frequently asked questions about drinking water in Langenstein, Mauthausen

How hard is the water in Langenstein, Mauthausen?
Wasserversorgung Rheinfelden publishes a total hardness of 25.3 °fH for the supply zone Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden — that corresponds to 14.2 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2025, retrieved on 07/08/2026.
How much nitrate is in the drinking water in Langenstein, Mauthausen?
Wasserversorgung Rheinfelden publishes a nitrate value of 9 mg/l for the supply zone Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden. The statutory parametric value is 40 mg/l; the measured value represents 23 % of the parametric value. Basis: 2025, retrieved on 07/08/2026.
Who supplies the drinking water in Langenstein, Mauthausen?
Wasserversorgung Rheinfelden. The values shown here come from the supply zone Gesamtes Stadtnetz, Industrie ost, Nachbargemeinden and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.