Drinking water in Königswartha
One supply zone, water supplier: Versorgungs GmbH Königswartha.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Wasserwerk Königswartha
Versorgungs GmbH KönigswarthaAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | <2,5 mg/l below limit of quantification | 50 mg/l | < 5 % * | Single value |
| Lead | <0,00050 mg/l below limit of quantification | 10 µg/l | < 5 % * | Single value |
| Escherichia coli (E. coli) | 0 KbE/100ml | 0/100 ml | — | Single value |
| Sulphate | 85,00 mg/l | 250 mg/l | 34 % | Single value |
| Sodium | 8,21 mg/l | 200 mg/l | 4 % | Single value |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (32 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 KbE/100ml | 0/100 ml | — | Single value |
| Intestinal enterococci | 0 KbE/100ml | 0/100 ml | — | Single value |
Chemical parameters (13)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | <0,0009 mg/l below limit of quantification | 3 µg/l | < 30 % * | Single value |
| Arsenic | <0,002 mg/l below limit of quantification | 10 µg/l | < 20 % * | Single value |
| Benzene | <0,0001 mg/l below limit of quantification | 1 µg/l | < 10 % * | Single value |
| Boron | <0,025 mg/l below limit of quantification | 1 mg/l | < 3 % * | Single value |
| Cadmium | <0,00070 mg/l below limit of quantification | 3 µg/l | < 23 % * | Single value |
| Chromium | <0,00050 mg/l below limit of quantification | 25 µg/l | < 2 % * | Single value |
| Copper | <0,005 mg/l below limit of quantification | 2 mg/l | < 0.3 % * | Single value |
| Fluoride | <0,05 mg/l below limit of quantification | 1.5 mg/l | < 3 % * | Single value |
| Lead | <0,00050 mg/l below limit of quantification | 10 µg/l | < 5 % * | Single value |
| Nickel | 0,0025 mg/l | 20 µg/l | 13 % | Single value |
| Nitrate | <2,5 mg/l below limit of quantification | 50 mg/l | < 5 % * | Single value |
| Nitrite | 0,03 mg/l | 0.5 mg/l | 6 % | Single value |
| Uranium | <0,00050 mg/l below limit of quantification | 10 µg/l | < 5 % * | Single value |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (14)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | <0,005 mg/l below limit of quantification | 0.2 mg/l | < 3 % * | Single value |
| Ammonium | 0,09 mg/l | 0.5 mg/l | 18 % | Single value |
| Chloride | 16,00 mg/l | 250 mg/l | 6 % | Single value |
| Coliform bacteria | 0 KbE/100 m | 0/100 ml | — | Single value |
| Colony count 22 °C | 0 KbE/ml | ohne anormale Veränderung | — | Single value |
| Colony count 36 °C | 0 KbE/ml | ohne anormale Veränderung | — | Single value |
| Conductivity (25 °C) | 336,00 µS/cm | 2,790 µS/cm | — | Single value |
| Iron | 0,033 mg/l | 0.2 mg/l | 17 % | Single value |
| Manganese | 0,008 mg/l | 50 µg/l | 16 % | Single value · Kontrolluntersuchung 27.04.2026 |
| Oxidisability | <1,0 mg/l O₂ below limit of quantification | 5 mg/l O2 | — | Single value |
| pH | 8,00 ohne | 6,5–9,5 | — | Single value |
| Sodium | 8,21 mg/l | 200 mg/l | 4 % | Single value |
| Sulphate | 85,00 mg/l | 250 mg/l | 34 % | Single value |
| Turbidity | 0,23 NTU | 1 NTU | — | Single value |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (3)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Calcium | 22,00 mg/l | — | — | Single value |
| Magnesium | 13,00 mg/l | — | — | Single value |
| Potassium | 4,00 mg/l | — | — | Single value |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 02699
Frequently asked questions about drinking water in Königswartha
- How much nitrate is in the drinking water in Königswartha?
- Versorgungs GmbH Königswartha publishes a nitrate value of <2,5 mg/l for the supply zone Wasserwerk Königswartha. The statutory parametric value is 50 mg/l; the measured value lies below it and cannot be specified more precisely below the limit of quantification. Basis: Publication by the water supplier, retrieved on 13/07/2026.
- Who supplies the drinking water in Königswartha?
- Versorgungs GmbH Königswartha. The values shown here come from the supply zone Wasserwerk Königswartha and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.