Drinking water in Kleinostheim
4 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Aschaffenburg
Aschaffenburger Versorgungs-GmbH (AVG)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (54 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Intestinal enterococci | 0 pro 100 ml | 0/100 ml | — | Mean |
Chemical parameters (24)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | < 0,0001 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Acrylamide | < 0,000025 mg/l below limit of quantification | 0.1 µg/l | < 25 % * | Mean |
| Antimony | < 0,001 mg/l below limit of quantification | 5 µg/l | < 20 % * | Mean |
| Arsenic | < 0,0005 mg/l below limit of quantification | 10 µg/l | < 5 % * | Mean |
| Benzene | < 0,0002 mg/l below limit of quantification | 1 µg/l | < 20 % * | Mean |
| Bisphenol A | < 0,0001 mg/l below limit of quantification | 2.5 µg/l | < 4 % * | Mean |
| Boron | 0,02 mg/l | 1 mg/l | 2 % | Mean |
| Bromate | < 0,002 mg/l below limit of quantification | 10 µg/l | < 20 % * | Mean |
| Cadmium | < 0,0003 mg/l below limit of quantification | 3 µg/l | < 10 % * | Mean |
| Chromium | < 0,0002 mg/l below limit of quantification | 25 µg/l | < 0.8 % * | Mean |
| Copper | 0,003 mg/l | 2 mg/l | 0.2 % | Mean |
| Cyanide | < 0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Epichlorohydrin | < 0,00005 mg/l below limit of quantification | 0.1 µg/l | < 50 % * | Mean |
| Fluoride | 0,08 mg/l | 1.5 mg/l | 5 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Mercury | < 0,0001 mg/l below limit of quantification | 1 µg/l | < 10 % * | Mean |
| Nickel | 0,001 mg/l | 20 µg/l | 5 % | Mean |
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Nitrite | < 0,004 mg/l below limit of quantification | 0.5 mg/l | < 0.8 % * | Mean |
| Polycyclic aromatic hydrocarbons | nicht nachweisbar mg/l not detectable | 0.1 µg/l | — | Mean |
| Selenium | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Tetrachloroethene and Trichloroethene (sum) | < 0,0002 mg/l below limit of quantification | 10 µg/l | < 2 % * | Mean |
| Uranium | 0,001 mg/l | 10 µg/l | 10 % | Mean |
| Vinyl chloride | < 0,0001 mg/l below limit of quantification | 0.5 µg/l | < 20 % * | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (17)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | < 0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Mean |
| Ammonium | < 0,018 mg/l below limit of quantification | 0.5 mg/l | < 4 % * | Mean |
| Calcite dissolution capacity | 0,0 mg/l | 5 mg/l CaCO3 | — | Mean |
| Chloride | 40 mg/l | 250 mg/l | 16 % | Mean |
| Clostridium perfringens (including spores) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Coliform bacteria | 0 pro 100 ml | 0/100 ml | — | Mean |
| Colony count 36 °C | 0 pro ml | ohne anormale Veränderung | — | Mean |
| Colour | < 0,01 m-1 below limit of quantification | 0.5 m⁻¹ | — | Mean |
| Conductivity (25 °C) | 522 µS/cm | 2,790 µS/cm | — | Mean |
| Iron | < 0,013 mg/l below limit of quantification | 0.2 mg/l | < 6 % * | Mean |
| Manganese | < 0,001 mg/l below limit of quantification | 50 µg/l | < 2 % * | Mean |
| pH | 7,7 | 6,5–9,5 | — | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Temperature | 12,0 °C | — | — | Mean |
| Total organic carbon (TOC) | 0,61 mg/l | ohne anormale Veränderung | — | Mean |
| Turbidity | 0,04 FNU | 1 NTU | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (11)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Acid capacity to pH 4.3 | 2,54 mmol/l | — | — | Mean |
| Base capacity to pH 8.2 | 0,09 mmol/l | — | — | Mean |
| Calcium | 65,3 mg/l | — | — | Mean |
| Carbonate hardness | 7,1 ° dH | — | — | Mean |
| Hardness range (WRMG) | mittel | — | — | Mean |
| Hydrogen carbonate | 155 mg/l | — | — | Mean |
| Lithium | 0,009 mg/l | — | — | Mean |
| Magnesium | 14,3 mg/l | — | — | Mean |
| Potassium | 3,1 mg/l | — | — | Mean |
| Silicate / silicic acid | 11,7 mg/l | — | — | Mean |
| Total hardness | 12,8 ° dH | — | — | Mean |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 63801
Show 3 more supply zones
aschaffenburg gesamt
Aschaffenburger Versorgungs-GmbH (AVG)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Sum of PFAS | 0,000 012 mg/l | 0.1 µg/l | 12 % | Mean |
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Sodium | 16 mg/l | 200 mg/l | 8 % | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (57 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Intestinal enterococci | 0 pro 100 ml | 0/100 ml | — | Mean |
Chemical parameters (24)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | < 0,000 1 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Acrylamide | < 0,000 025 mg/l below limit of quantification | 0.1 µg/l | < 25 % * | Mean |
| Antimony | < 0,001 mg/l below limit of quantification | 5 µg/l | < 20 % * | Mean |
| Arsenic | < 0,000 5 mg/l below limit of quantification | 10 µg/l | < 5 % * | Mean |
| Benzene | < 0,000 2 mg/l below limit of quantification | 1 µg/l | < 20 % * | Mean |
| Bisphenol A | < 0,000 1 mg/l below limit of quantification | 2.5 µg/l | < 4 % * | Mean |
| Boron | 0,02 mg/l | 1 mg/l | 2 % | Mean |
| Bromate | < 0,002 mg/l below limit of quantification | 10 µg/l | < 20 % * | Mean |
| Cadmium | < 0,000 3 mg/l below limit of quantification | 3 µg/l | < 10 % * | Mean |
| Chromium | < 0,000 2 mg/l below limit of quantification | 25 µg/l | < 0.8 % * | Mean |
| Copper | 0,009 mg/l | 2 mg/l | 0.4 % | Mean |
| Cyanide | < 0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Epichlorohydrin | < 0,000 05 mg/l below limit of quantification | 0.1 µg/l | < 50 % * | Mean |
| Fluoride | 0,10 mg/l | 1.5 mg/l | 7 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Mercury | < 0,000 1 mg/l below limit of quantification | 1 µg/l | < 10 % * | Mean |
| Nickel | 0,001 mg/l | 20 µg/l | 5 % | Mean |
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Nitrite | < 0,004 mg/l below limit of quantification | 0.5 mg/l | < 0.8 % * | Mean |
| Polycyclic aromatic hydrocarbons | nicht nachweisbar mg/l not detectable | 0.1 µg/l | — | Mean |
| Selenium | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Tetrachloroethene and Trichloroethene (sum) | < 0,000 2 mg/l below limit of quantification | 10 µg/l | < 2 % * | Mean |
| Uranium | 0,002 mg/l | 10 µg/l | 20 % | Mean |
| Vinyl chloride | < 0,000 1 mg/l below limit of quantification | 0.5 µg/l | < 20 % * | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
PFAS (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Sum of 4 PFAS | 0,000 003 mg/l | — | — | Mean |
| Sum of PFAS | 0,000 012 mg/l | 0.1 µg/l | 12 % | Mean |
Indicator parameters (18)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | < 0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Mean |
| Ammonium | < 0,016 mg/l below limit of quantification | 0.5 mg/l | < 3 % * | Mean |
| Calcite dissolution capacity | -4,5 mg/l | 5 mg/l CaCO3 | — | Mean |
| Chloride | 40 mg/l | 250 mg/l | 16 % | Mean |
| Clostridium perfringens (including spores) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Coliform bacteria | 0 pro 100 ml | 0/100 ml | — | Mean |
| Colony count 22 °C | 0 pro ml | ohne anormale Veränderung | — | Mean |
| Colony count 36 °C | 6 pro ml | ohne anormale Veränderung | — | Mean |
| Colour | < 0,02 m-1 below limit of quantification | 0.5 m⁻¹ | — | Mean |
| Conductivity (25 °C) | 540 µS/cm | 2,790 µS/cm | — | Mean |
| Iron | < 0,015 mg/l below limit of quantification | 0.2 mg/l | < 8 % * | Mean |
| Manganese | < 0,001 mg/l below limit of quantification | 50 µg/l | < 2 % * | Mean |
| pH | 7,7 | 6,5–9,5 | — | Mean |
| Sodium | 16 mg/l | 200 mg/l | 8 % | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Temperature | 12,3 °C | — | — | Mean |
| Total organic carbon (TOC) | 0,61 mg/l | ohne anormale Veränderung | — | Mean |
| Turbidity | 0,06 FNU | 1 NTU | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (11)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Acid capacity to pH 4.3 | 2,7 mmol/l | — | — | Mean |
| Base capacity to pH 8.2 | 0,09 mmol/l | — | — | Mean |
| Calcium | 67 mg/l | — | — | Mean |
| Carbonate hardness | 7,1 ° dH | — | — | Mean |
| Hardness range (WRMG) | mittel | — | — | Mean |
| Hydrogen carbonate | 165 mg/l | — | — | Mean |
| Lithium | 0,009 mg/l | — | — | Mean |
| Magnesium | 14 mg/l | — | — | Mean |
| Potassium | 3,3 mg/l | — | — | Mean |
| Silicate / silicic acid | 12 mg/l | — | — | Mean |
| Total hardness | 12,4 ° dH | — | — | Mean |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 63801
Aschaffenburg (Wasserwerk Niedernberger Straße 52, 63741 Aschaffenburg)
Aschaffenburger Versorgungs-GmbH (AVG)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Lead | <0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (54 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Intestinal enterococci | 0 pro 100 ml | 0/100 ml | — | Mean |
Chemical parameters (24)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | <0,0001 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Acrylamide | <0,000025 mg/l below limit of quantification | 0.1 µg/l | < 25 % * | Mean |
| Antimony | <0,001 mg/l below limit of quantification | 5 µg/l | < 20 % * | Mean |
| Arsenic | <0,0005 mg/l below limit of quantification | 10 µg/l | < 5 % * | Mean |
| Benzene | <0,0002 mg/l below limit of quantification | 1 µg/l | < 20 % * | Mean |
| Bisphenol A | <0,0001 mg/l below limit of quantification | 2.5 µg/l | < 4 % * | Mean |
| Boron | 0,02 mg/l | 1 mg/l | 2 % | Mean |
| Bromate | <0,002 mg/l below limit of quantification | 10 µg/l | < 20 % * | Mean |
| Cadmium | <0,0003 mg/l below limit of quantification | 3 µg/l | < 10 % * | Mean |
| Chromium | <0,0002 mg/l below limit of quantification | 25 µg/l | < 0.8 % * | Mean |
| Copper | 0,003 mg/l | 2 mg/l | 0.2 % | Mean |
| Cyanide | <0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Epichlorohydrin | <0,00005 mg/l below limit of quantification | 0.1 µg/l | < 50 % * | Mean |
| Fluoride | 0,08 mg/l | 1.5 mg/l | 5 % | Mean |
| Lead | <0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Mercury | <0,0001 mg/l below limit of quantification | 1 µg/l | < 10 % * | Mean |
| Nickel | 0,001 mg/l | 20 µg/l | 5 % | Mean |
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Nitrite | <0,004 mg/l below limit of quantification | 0.5 mg/l | < 0.8 % * | Mean |
| Polycyclic aromatic hydrocarbons | nicht nachweisbar mg/l not detectable | 0.1 µg/l | — | Mean |
| Selenium | <0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Tetrachloroethene and Trichloroethene (sum) | <0,0002 mg/l below limit of quantification | 10 µg/l | < 2 % * | Mean |
| Uranium | 0,001 mg/l | 10 µg/l | 10 % | Mean |
| Vinyl chloride | <0,0001 mg/l below limit of quantification | 0.5 µg/l | < 20 % * | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (17)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | <0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Mean |
| Ammonium | <0,018 mg/l below limit of quantification | 0.5 mg/l | < 4 % * | Mean |
| Calcite dissolution capacity | 0,0 mg/l | 5 mg/l CaCO3 | — | Mean |
| Chloride | 40 mg/l | 250 mg/l | 16 % | Mean |
| Clostridium perfringens (including spores) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Coliform bacteria | 0 pro 100 ml | 0/100 ml | — | Mean |
| Colony count 36 °C | 0 pro ml | ohne anormale Veränderung | — | Mean |
| Colour | <0,01 m-1 below limit of quantification | 0.5 m⁻¹ | — | Mean |
| Conductivity (25 °C) | 522 µS/cm | 2,790 µS/cm | — | Mean |
| Iron | <0,013 mg/l below limit of quantification | 0.2 mg/l | < 6 % * | Mean |
| Manganese | <0,001 mg/l below limit of quantification | 50 µg/l | < 2 % * | Mean |
| pH | 7,7 | 6,5–9,5 | — | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Temperature | 12,0 °C | — | — | Mean |
| Total organic carbon (TOC) | 0,61 mg/l | ohne anormale Veränderung | — | Mean |
| Turbidity | 0,04 FNU | 1 NTU | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (11)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Acid capacity to pH 4.3 | 2,54 mmol/l | — | — | Mean |
| Base capacity to pH 8.2 | 0,09 mmol/l | — | — | Mean |
| Calcium | 65,3 mg/l | — | — | Mean |
| Carbonate hardness | 7,1 ° dH | — | — | Mean |
| Hardness range (WRMG) | mittel | — | — | Mean |
| Hydrogen carbonate | 155 mg/l | — | — | Mean |
| Lithium | 0,009 mg/l | — | — | Mean |
| Magnesium | 14,3 mg/l | — | — | Mean |
| Potassium | 3,1 mg/l | — | — | Mean |
| Silicate / silicic acid | 11,7 mg/l | — | — | Mean |
| Total hardness | 12,8 ° dH | — | — | Mean |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 63801
Wasserwerk Aschaffenburg, Niedernberger Straße 52, 63741 Aschaffenburg
Aschaffenburger Versorgungs-GmbH (AVG)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (54 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Intestinal enterococci | 0 pro 100 ml | 0/100 ml | — | Mean |
Chemical parameters (24)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | < 0,0001 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Acrylamide | < 0,000025 mg/l below limit of quantification | 0.1 µg/l | < 25 % * | Mean |
| Antimony | < 0,001 mg/l below limit of quantification | 5 µg/l | < 20 % * | Mean |
| Arsenic | < 0,0005 mg/l below limit of quantification | 10 µg/l | < 5 % * | Mean |
| Benzene | < 0,0002 mg/l below limit of quantification | 1 µg/l | < 20 % * | Mean |
| Bisphenol A | < 0,0001 mg/l below limit of quantification | 2.5 µg/l | < 4 % * | Mean |
| Boron | 0,02 mg/l | 1 mg/l | 2 % | Mean |
| Bromate | < 0,002 mg/l below limit of quantification | 10 µg/l | < 20 % * | Mean |
| Cadmium | < 0,0003 mg/l below limit of quantification | 3 µg/l | < 10 % * | Mean |
| Chromium | < 0,0002 mg/l below limit of quantification | 25 µg/l | < 0.8 % * | Mean |
| Copper | 0,003 mg/l | 2 mg/l | 0.2 % | Mean |
| Cyanide | < 0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Epichlorohydrin | < 0,00005 mg/l below limit of quantification | 0.1 µg/l | < 50 % * | Mean |
| Fluoride | 0,08 mg/l | 1.5 mg/l | 5 % | Mean |
| Lead | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Mercury | < 0,0001 mg/l below limit of quantification | 1 µg/l | < 10 % * | Mean |
| Nickel | 0,001 mg/l | 20 µg/l | 5 % | Mean |
| Nitrate | 27 mg/l | 50 mg/l | 54 % | Mean |
| Nitrite | < 0,004 mg/l below limit of quantification | 0.5 mg/l | < 0.8 % * | Mean |
| Polycyclic aromatic hydrocarbons | nicht nachweisbar mg/l not detectable | 0.1 µg/l | — | Mean |
| Selenium | < 0,001 mg/l below limit of quantification | 10 µg/l | < 10 % * | Mean |
| Tetrachloroethene and Trichloroethene (sum) | < 0,0002 mg/l below limit of quantification | 10 µg/l | < 2 % * | Mean |
| Uranium | 0,001 mg/l | 10 µg/l | 10 % | Mean |
| Vinyl chloride | < 0,0001 mg/l below limit of quantification | 0.5 µg/l | < 20 % * | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (17)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | < 0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Mean |
| Ammonium | < 0,018 mg/l below limit of quantification | 0.5 mg/l | < 4 % * | Mean |
| Calcite dissolution capacity | 0,0 mg/l | 5 mg/l CaCO3 | — | Mean |
| Chloride | 40 mg/l | 250 mg/l | 16 % | Mean |
| Clostridium perfringens (including spores) | 0 pro 100 ml | 0/100 ml | — | Mean |
| Coliform bacteria | 0 pro 100 ml | 0/100 ml | — | Mean |
| Colony count 36 °C | 0 pro ml | ohne anormale Veränderung | — | Mean |
| Colour | < 0,01 m-1 below limit of quantification | 0.5 m⁻¹ | — | Mean |
| Conductivity (25 °C) | 522 µS/cm | 2,790 µS/cm | — | Mean |
| Iron | < 0,013 mg/l below limit of quantification | 0.2 mg/l | < 6 % * | Mean |
| Manganese | < 0,001 mg/l below limit of quantification | 50 µg/l | < 2 % * | Mean |
| pH | 7,7 | 6,5–9,5 | — | Mean |
| Sodium | 15,5 mg/l | 200 mg/l | 8 % | Mean |
| Sulphate | 52 mg/l | 250 mg/l | 21 % | Mean |
| Temperature | 12,0 °C | — | — | Mean |
| Total organic carbon (TOC) | 0,61 mg/l | ohne anormale Veränderung | — | Mean |
| Turbidity | 0,04 FNU | 1 NTU | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (11)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Acid capacity to pH 4.3 | 2,54 mmol/l | — | — | Mean |
| Base capacity to pH 8.2 | 0,09 mmol/l | — | — | Mean |
| Calcium | 65,3 mg/l | — | — | Mean |
| Carbonate hardness | 7,1 ° dH | — | — | Mean |
| Hardness range (WRMG) | mittel | — | — | Mean |
| Hydrogen carbonate | 155 mg/l | — | — | Mean |
| Lithium | 0,009 mg/l | — | — | Mean |
| Magnesium | 14,3 mg/l | — | — | Mean |
| Potassium | 3,1 mg/l | — | — | Mean |
| Silicate / silicic acid | 11,7 mg/l | — | — | Mean |
| Total hardness | 12,8 ° dH | — | — | Mean |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 63801
Frequently asked questions about drinking water in Kleinostheim
- How hard is the water in Kleinostheim?
- Aschaffenburger Versorgungs-GmbH (AVG) publishes a total hardness of 12.8 °dH for the supply zone Aschaffenburg (hardness range mittel). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Stand 2024, retrieved on 13/07/2026.
- How much nitrate is in the drinking water in Kleinostheim?
- Aschaffenburger Versorgungs-GmbH (AVG) publishes a nitrate value of 27 mg/l for the supply zone Aschaffenburg. The statutory parametric value is 50 mg/l; the measured value represents 54 % of the parametric value. Basis: Stand 2024, retrieved on 13/07/2026.
- Who supplies the drinking water in Kleinostheim?
- Aschaffenburger Versorgungs-GmbH (AVG). The values shown here come from the supply zone Aschaffenburg and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.