Skip to content
maunawai.info

Drinking water in Ingenried

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

DU 7 (Kindergarten, Stagnationsprobe)

Gemeinde Ingenried

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values DU 7 (Kindergarten, Stagnationsprobe)
Parameter Value Parametric value Share of the parametric value Reference
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · DU 7 (Kindergarten, Stagnationsprobe)

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (8 — most recent value per parameter)

Chemical parameters (3)

Chemical parameters – DU 7 (Kindergarten, Stagnationsprobe)
Parameter Value Parametric value Share of the parametric value Reference
Copper <0,005 mg/l
below limit of quantification
2 mg/l
< 0.3 % *
Single value · DU 7 (Kindergarten, Stagnationsprobe)
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · DU 7 (Kindergarten, Stagnationsprobe)
Nickel <0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value · DU 7 (Kindergarten, Stagnationsprobe)

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (5)

Indicator parameters – DU 7 (Kindergarten, Stagnationsprobe)
Parameter Value Parametric value Share of the parametric value Reference
Colour farblos
Unit not stated in the document
0.5 m⁻¹ Single value · DU 7 (Kindergarten, Stagnationsprobe)
Odour ohne für den Verbraucher annehmbar Single value · DU 7 (Kindergarten, Stagnationsprobe)
Taste ohne für den Verbraucher annehmbar Single value · DU 7 (Kindergarten, Stagnationsprobe)
Temperature 11,8 °C Single value · DU 7 (Kindergarten, Stagnationsprobe)
Turbidity klar
Unit not stated in the document
1 NTU Single value · DU 7 (Kindergarten, Stagnationsprobe)

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.ingenried.de/fileadmin/users/13/Trinkwasseruntersuchung.pdf · 21.11.2025 · Probenahme 18.11.2025 · retrieved on 08/08/2026

Postcodes in this zone: 86980

Show 1 more supply zone

DU 8 (Personal, WC WB)

Gemeinde Ingenried

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
19 °dH
Hardness range hart
Key values DU 8 (Personal, WC WB)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 4,6 mg/l 50 mg/l
9 %
Single value · DU 8 (Personal, WC WB)
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · DU 8 (Personal, WC WB)
Sulphate 6,3 mg/l 250 mg/l
3 %
Single value · DU 8 (Personal, WC WB)
Sodium 1,8 mg/l 200 mg/l
0.9 %
Single value · DU 8 (Personal, WC WB)

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (88 — most recent value per parameter)

Microbiology (2)

Microbiology – DU 8 (Personal, WC WB)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · DU 8 (Personal, WC WB)
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value · DU 8 (Personal, WC WB)

Chemical parameters (50)

Chemical parameters – DU 8 (Personal, WC WB)
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,0005 mg/l
below limit of quantification
3 µg/l
< 17 % *
Single value · DU 8 (Personal, WC WB)
Antimony <0,0005 mg/l
below limit of quantification
5 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Arsenic <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Atrazine <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Bentazone <0,000015 (NWG) mg/l
not detectable
Single value · DU 8 (Personal, WC WB)
Benzene <0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Benzo(a)pyrene <0,000002 mg/l
below limit of quantification
10 ng/l
< 20 % *
Single value · DU 8 (Personal, WC WB)
Benzo(b)fluoranthene <0,000002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Benzo(ghi)perylene <0,000002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Benzo(k)fluoranthene <0,000002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Bisphenol A <0,000050 (NWG) mg/l
not detectable
2.5 µg/l Single value · DU 8 (Personal, WC WB)
Boron <0,02 mg/l
below limit of quantification
1 mg/l
< 2 % *
Single value · DU 8 (Personal, WC WB)
Bromate <0,0030 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value · DU 8 (Personal, WC WB)
Bromodichloromethane <0,0002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Cadmium <0,0003 mg/l
below limit of quantification
3 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Chromium <0,00050 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value · DU 8 (Personal, WC WB)
Copper <0,005 mg/l
below limit of quantification
2 mg/l
< 0.3 % *
Single value · DU 8 (Personal, WC WB)
Cyanide <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Desethylatrazine <0,00001 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Desethylterbuthylazine <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Desisopropylatrazine <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Dibromochloromethane <0,0002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Dicamba <0,00003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Fluoride 0,043 mg/l 1.5 mg/l
3 %
Single value · DU 8 (Personal, WC WB)
Fluroxypyr <0,00003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Indeno(1,2,3-cd)pyrene <0,000002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Isoproturon <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
MCPA <0,00003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Mercury <0,00010 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Metolachlor <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Nickel <0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Nitrate 4,6 mg/l 50 mg/l
9 %
Single value · DU 8 (Personal, WC WB)
Nitrate/50 + Nitrite/3 0,092 mg/l 1 Single value · DU 8 (Personal, WC WB)
Nitrite <0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value · DU 8 (Personal, WC WB)
Pesticides — Total 0 mg/l 0.5 µg/l
0 %
Single value · DU 8 (Personal, WC WB)
Polycyclic aromatic hydrocarbons 0 mg/l 0.1 µg/l
0 %
Single value · DU 8 (Personal, WC WB)
Selenium <0,0005 mg/l
below limit of quantification
10 µg/l
< 5 % *
Single value · DU 8 (Personal, WC WB)
Simazine <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Terbuthylazine <0,00002 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Tetrachloroethene <0,0001 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Tetrachloroethene and Trichloroethene (sum) 0 mg/l 10 µg/l
0 %
Single value · DU 8 (Personal, WC WB)
Thifensulfuron-methyl <0,00003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Tribromomethane (bromoform) <0,0003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Trichloroethene <0,0001 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Trichloromethane (chloroform) <0,0001 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Triclopyr <0,00003 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Trihalomethanes — Total 0 mg/l 50 µg/l
0 %
Single value · DU 8 (Personal, WC WB)
Uranium 0,0005 mg/l 10 µg/l
5 %
Single value · DU 8 (Personal, WC WB)
Vinyl chloride <0,0001 mg/l
below limit of quantification
0.5 µg/l
< 20 % *
Single value · DU 8 (Personal, WC WB)

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (20)

Indicator parameters – DU 8 (Personal, WC WB)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,020 mg/l
below limit of quantification
0.2 mg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Ammonium <0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value · DU 8 (Personal, WC WB)
Calcite dissolution capacity -42 mg/l 5 mg/l CaCO3 Single value · DU 8 (Personal, WC WB)
Chloride 2,0 mg/l 250 mg/l
0.8 %
Single value · DU 8 (Personal, WC WB)
Clostridium perfringens (including spores) 0 KBE/100ml 0/100 ml Single value · DU 8 (Personal, WC WB)
Coliform bacteria 0 KBE/100ml 0/100 ml Single value · DU 8 (Personal, WC WB)
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value · DU 8 (Personal, WC WB)
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value · DU 8 (Personal, WC WB)
Colour <0,1 m-1
below limit of quantification
0.5 m⁻¹ Single value · DU 8 (Personal, WC WB)
Conductivity (25 °C) 612 µS/cm 2,790 µS/cm Single value · DU 8 (Personal, WC WB)
Iron <0,005 mg/l
below limit of quantification
0.2 mg/l
< 3 % *
Single value · DU 8 (Personal, WC WB)
Manganese <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value · DU 8 (Personal, WC WB)
Odour ohne für den Verbraucher annehmbar Single value · DU 8 (Personal, WC WB)
pH 7,26 6,5–9,5 Single value · DU 8 (Personal, WC WB)
Sodium 1,8 mg/l 200 mg/l
0.9 %
Single value · DU 8 (Personal, WC WB)
Sulphate 6,3 mg/l 250 mg/l
3 %
Single value · DU 8 (Personal, WC WB)
Taste ohne für den Verbraucher annehmbar Single value · DU 8 (Personal, WC WB)
Temperature 12,3 °C Single value · DU 8 (Personal, WC WB)
Total organic carbon (TOC) <0,5 mg/l
below limit of quantification
ohne anormale Veränderung Single value · DU 8 (Personal, WC WB)
Turbidity 0,05 NTU 1 NTU Single value · DU 8 (Personal, WC WB)

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (16)

Further parameters – DU 8 (Personal, WC WB)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 6,74 mmol/l Single value · DU 8 (Personal, WC WB)
Base capacity to pH 8.2 0,61 mmol/l Single value · DU 8 (Personal, WC WB)
Calcite-dissolving carbon dioxide 0,0 mg/l Single value · DU 8 (Personal, WC WB)
Calcium 112 mg/l Single value · DU 8 (Personal, WC WB)
Carbonate hardness 18,7 °dH Single value · DU 8 (Personal, WC WB)
Copper quotient 102,44 Single value · DU 8 (Personal, WC WB)
Equilibrium carbon dioxide 27 mg/l Single value · DU 8 (Personal, WC WB)
Free carbon dioxide 27 mg/l Single value · DU 8 (Personal, WC WB)
Hardness range (WRMG) hart Single value · DU 8 (Personal, WC WB)
Magnesium 14,3 mg/l Single value · DU 8 (Personal, WC WB)
Phosphate <0,05 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Pitting corrosion quotient S1 0,04 Single value · DU 8 (Personal, WC WB)
Potassium <0,5 mg/l
below limit of quantification
Single value · DU 8 (Personal, WC WB)
Total hardness 3,38 mmol/l Single value · DU 8 (Personal, WC WB)
Total mineralisation 552 mg/l Single value · DU 8 (Personal, WC WB)
Trickling quotient 2,53 Single value · DU 8 (Personal, WC WB)

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.ingenried.de/fileadmin/users/13/Trinkwasseruntersuchung.pdf · 21.11.2025 · Probenahme 18.11.2025 · retrieved on 08/08/2026

Postcodes in this zone: 86980

Frequently asked questions about drinking water in Ingenried

Who supplies the drinking water in Ingenried?
Gemeinde Ingenried. The values shown here come from the supply zone DU 7 (Kindergarten, Stagnationsprobe) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.