Drinking water in Hünibach
One supply zone, water supplier: Wasserversorgung Gemeinde Hilterfingen.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Hilterfingen - Hünibach
Wasserversorgung Gemeinde HilterfingenAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 8.3 mg/l | 40 mg/l | 21 % | Mean · Hilterfingen - Hünibach |
| Escherichia coli (E. coli) | 0 KBE/100ml | 0/100 ml | — | Maximum · Median 0 · Hilterfingen - Hünibach |
| Sulphate | 6.16 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Sodium | 5.35 mg/l | 200 mg/l | 3 % | Mean · Hilterfingen - Hünibach |
Show all recorded parameters (17 — most recent value per parameter)
Microbiology (3)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aerobic mesophilic bacteria | 1.26 KBE/ml | 300 1/ml | — | Mean · Hilterfingen - Hünibach |
| Escherichia coli (E. coli) | 0 KBE/100ml | 0/100 ml | — | Maximum · Median 0 · Hilterfingen - Hünibach |
| Intestinal enterococci | 0 KBE/100ml | 0/100 ml | — | Maximum · Median 0 · Hilterfingen - Hünibach |
Chemical parameters (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Fluoride | 0.05 mg/l above | 1.5 mg/l | 3 % | Mean · Hilterfingen - Hünibach |
| Nitrate | 8.3 mg/l | 40 mg/l | 21 % | Mean · Hilterfingen - Hünibach |
Indicator parameters (6)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Chloride | 9.77 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Conductivity (25 °C) | 499.5 µS/cm | — | — | Mean · Hilterfingen - Hünibach |
| Sodium | 5.35 mg/l | 200 mg/l | 3 % | Mean · Hilterfingen - Hünibach |
| Sulphate | 6.16 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Temperature | 7.83 °C | — | — | Mean · Hilterfingen - Hünibach |
| Turbidity | 0.12 TE/F | — | — | Mean · Hilterfingen - Hünibach |
Further parameters (6)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Calcium | 92.35 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Dissolved organic carbon (DOC) | 0.77 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Hydrogen carbonate | 284.52 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Magnesium | 3.3 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Potassium | 1.12 mg/l | — | — | Mean · Hilterfingen - Hünibach |
| Total hardness | 30.62 °fH | — | — | Mean · Hilterfingen - Hünibach |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 3626
Frequently asked questions about drinking water in Hünibach
- How hard is the water in Hünibach?
- Wasserversorgung Gemeinde Hilterfingen publishes a total hardness of 30.62 °fH for the supply zone Hilterfingen - Hünibach — that corresponds to 17.1 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2026, retrieved on 07/08/2026.
- How much nitrate is in the drinking water in Hünibach?
- Wasserversorgung Gemeinde Hilterfingen publishes a nitrate value of 8.3 mg/l for the supply zone Hilterfingen - Hünibach. The statutory parametric value is 40 mg/l; the measured value represents 21 % of the parametric value. Basis: 2026, retrieved on 07/08/2026.
- Who supplies the drinking water in Hünibach?
- Wasserversorgung Gemeinde Hilterfingen. The values shown here come from the supply zone Hilterfingen - Hünibach and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.