Skip to content
maunawai.info

Drinking water in Hinterstoder, Klaus an der Pyhrnbahn, St. Pankraz

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values WV Hutterer Böden
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Show all recorded parameters (11 — most recent value per parameter)

Microbiology (2)

Microbiology – WV Hutterer Böden
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Indicator parameters (9)

Indicator parameters – WV Hutterer Böden
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 9 KBE/ml 100 1/ml Single value
Colony count 36 °C 1 KBE/ml 20 1/ml Single value
Colour farblos, klar, ohne Bodensatz Single value
Conductivity (25 °C) 262 µS/cm 2,500 µS/cm Single value
Odour geruchlos Single value
pH 8,1 - 6,5–9,5 Single value
Taste geschmacklos Single value
Temperature 8,5 °C Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.hinterstoder.ooe.gv.at/system/web/getDocument.ashx?cts=1763721078&fileid=4126517 · 20.11.2025 · 11.11.2025 (Probenahme) · retrieved on 14/08/2026

Postcodes in this zone: 4572

Show 1 more supply zone

WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)

Gemeinde Hinterstoder / WV Hutterer Böden

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
12.5 °dH
Hardness range medium
Key values WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 4,91 mg/l 50 mg/l
10 %
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 42,2 mg/l 250 mg/l
17 %
Single value
Sodium 1,07 mg/l 200 mg/l
0.5 %
Single value
Show all recorded parameters (28 — most recent value per parameter)

Microbiology (2)

Microbiology – WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (3)

Chemical parameters – WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 4,91 mg/l 50 mg/l
10 %
Single value
Nitrate/50 + Nitrite/3 0,102 mg/l Single value
Nitrite <0,01 mg/l
below limit of quantification
0.1 mg/l
< 10 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (16)

Indicator parameters – WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value
Chloride 1,3 mg/l 200 mg/l
0.7 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 22 KBE/ml 100 1/ml Single value
Colony count 36 °C 1 KBE/ml 20 1/ml Single value
Colour farblos, klar, ohne Bodensatz Single value
Conductivity (25 °C) 357 µS/cm 2,500 µS/cm Single value
Iron <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Odour geruchlos Single value
Oxidisability 0,40 mg O2/l 5 mg/l Single value
pH 8,2 - 6,5–9,5 Single value
Sodium 1,07 mg/l 200 mg/l
0.5 %
Single value
Sulphate 42,2 mg/l 250 mg/l
17 %
Single value
Taste geschmacklos Single value
Temperature 11,6 °C Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – WV Tambergau, Entnahmestelle 04, Netzauslauf Fröhlichsiedlung (Drucksteigerung)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 3,28 mmol/l Single value
Calcium 60,9 mg/l 400 mg/l
15 %
Single value
Carbonate hardness 9,04 °dH Single value
Hydrogen carbonate 197 mg/l Single value
Magnesium 17,2 mg/l 150 mg/l
11 %
Single value
Potassium <0,5 mg/l
below limit of quantification
50 mg/l
< 1 % *
Single value
Total hardness 2,23 mmol/l Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.hinterstoder.ooe.gv.at/system/web/getDocument.ashx?cts=1763455980&fileid=4122905 · 15.11.2025 · Probenahme 11.11.2025 · retrieved on 14/08/2026

Postcodes in this zone: 4572

Frequently asked questions about drinking water in Hinterstoder, Klaus an der Pyhrnbahn, St. Pankraz

Who supplies the drinking water in Hinterstoder, Klaus an der Pyhrnbahn, St. Pankraz?
Gemeinde Hinterstoder / WV Hutterer Böden. The values shown here come from the supply zone WV Hutterer Böden and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.