Drinking water in Heikendorf
One supply zone, water supplier: Gemeindewerke Heikendorf AöR.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Heikendorf
Gemeindewerke Heikendorf AöRAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 1,93 mg/l | 50 mg/l | 4 % | Single value |
| Escherichia coli (E. coli) | 0 KBE/100ml | 0/100 ml | — | Single value |
| Sulphate | 46 mg/l | 250 mg/l | 18 % | Single value |
| Sodium | 48,8 mg/l | 200 mg/l | 24 % | Single value |
Show all recorded parameters (24 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 KBE/100ml | 0/100 ml | — | Single value |
| Intestinal enterococci | 0 KBE/100ml | 0/100 ml | — | Single value |
Chemical parameters (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Nitrate | 1,93 mg/l | 50 mg/l | 4 % | Single value |
| Nitrite | <0,001 mg/l below limit of quantification | 0.5 mg/l | < 0.2 % * | Single value |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Indicator parameters (14)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | <0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Single value |
| Ammonium | <0,005 mg/l below limit of quantification | 0.5 mg/l | < 1 % * | Single value |
| Calcite dissolution capacity | -35,0 mg/l | 5 mg/l CaCO3 | — | Single value |
| Chloride | 58 mg/l | 250 mg/l | 23 % | Single value |
| Coliform bacteria | 0 KBE/100ml | 0/100 ml | — | Single value |
| Colony count 36 °C | 0 KBE/1ml | ohne anormale Veränderung | — | Single value |
| Conductivity (25 °C) | 800 µS/cm | 2,790 µS/cm | — | Single value |
| Iron | 0,014 mg/l | 0.2 mg/l | 7 % | Single value |
| Manganese | <0,002 mg/l below limit of quantification | 50 µg/l | < 4 % * | Single value |
| pH | 7,62 | 6,5–9,5 | — | Single value |
| Sodium | 48,8 mg/l | 200 mg/l | 24 % | Single value |
| Sulphate | 46 mg/l | 250 mg/l | 18 % | Single value |
| Temperature | 8,5 °C | — | — | Single value |
| Turbidity | 0,11 NTU | 1 NTU | — | Single value |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (6)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Calcium | 105 mg/l | — | — | Single value |
| Hardness range (WRMG) | hart - | — | — | Single value |
| Hydrogen carbonate | 357,6 mg/l | — | — | Single value |
| Magnesium | 11,6 mg/l | — | — | Single value |
| Potassium | 3,1 mg/l | — | — | Single value |
| Total hardness | 17,4 °dH | — | — | Single value |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Postcodes in this zone: 24226
Frequently asked questions about drinking water in Heikendorf
- How hard is the water in Heikendorf?
- Gemeindewerke Heikendorf AöR publishes a total hardness of 17.4 °dH for the supply zone Heikendorf (hardness range hart). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Analyse durch LUFA-ITL vom April 2026, retrieved on 14/07/2026.
- How much nitrate is in the drinking water in Heikendorf?
- Gemeindewerke Heikendorf AöR publishes a nitrate value of 1,93 mg/l for the supply zone Heikendorf. The statutory parametric value is 50 mg/l; the measured value represents 4 % of the parametric value. Basis: Analyse durch LUFA-ITL vom April 2026, retrieved on 14/07/2026.
- Who supplies the drinking water in Heikendorf?
- Gemeindewerke Heikendorf AöR. The values shown here come from the supply zone Heikendorf and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.