Skip to content
maunawai.info

Drinking water in Furth bei Göttweig

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

3511, Furth/Palt

EVN Wasser GesmbH
Water hardness
11.6 °dH
Hardness range medium
Key values 3511, Furth/Palt
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,5 mg/l 50 mg/l
11 %
Single value · 3511, Furth/Palt
Sulphate 27 mg/l 250 mg/l
11 %
Single value · 3511, Furth/Palt
Sodium 12 mg/l 200 mg/l
6 %
Single value · 3511, Furth/Palt
Show all recorded parameters (11 — most recent value per parameter)

Chemical parameters (2)

Chemical parameters – 3511, Furth/Palt
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,5 mg/l 50 mg/l
11 %
Single value · 3511, Furth/Palt
Pesticides < 0,1 µg/l
below limit of quantification
0.1 µg/l cannot be assessed — the limit of quantification of the measurement is above the parametric value Single value · 3511, Furth/Palt

Indicator parameters (4)

Indicator parameters – 3511, Furth/Palt
Parameter Value Parametric value Share of the parametric value Reference
Chloride 16 mg/l 200 mg/l
8 %
Single value · 3511, Furth/Palt
pH 7,8 6,5–9,5 Single value · 3511, Furth/Palt
Sodium 12 mg/l 200 mg/l
6 %
Single value · 3511, Furth/Palt
Sulphate 27 mg/l 250 mg/l
11 %
Single value · 3511, Furth/Palt

Further parameters (5)

Further parameters – 3511, Furth/Palt
Parameter Value Parametric value Share of the parametric value Reference
Calcium 60 mg/l 400 mg/l
15 %
Single value · 3511, Furth/Palt
Carbonate hardness 10 °dH Single value · 3511, Furth/Palt
Magnesium 14 mg/l 150 mg/l
9 %
Single value · 3511, Furth/Palt
Potassium 2,5 mg/l 50 mg/l
5 %
Single value · 3511, Furth/Palt
Total hardness 11,6 °dH Single value · 3511, Furth/Palt

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.evn.at/home/wasser/wasserwerte · 2026-01-28 · 2026-01-28 · retrieved on 08/07/2026

Postcodes in this zone: 3511

Show 1 more supply zone

3511, Oberfucha

EVN Wasser GesmbH
Water hardness
11.6 °dH
Hardness range medium
Key values 3511, Oberfucha
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,5 mg/l 50 mg/l
11 %
Single value · 3511, Oberfucha
Sulphate 27 mg/l 250 mg/l
11 %
Single value · 3511, Oberfucha
Sodium 12 mg/l 200 mg/l
6 %
Single value · 3511, Oberfucha
Show all recorded parameters (11 — most recent value per parameter)

Chemical parameters (2)

Chemical parameters – 3511, Oberfucha
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,5 mg/l 50 mg/l
11 %
Single value · 3511, Oberfucha
Pesticides < 0,1 µg/l
below limit of quantification
0.1 µg/l cannot be assessed — the limit of quantification of the measurement is above the parametric value Single value · 3511, Oberfucha

Indicator parameters (4)

Indicator parameters – 3511, Oberfucha
Parameter Value Parametric value Share of the parametric value Reference
Chloride 16 mg/l 200 mg/l
8 %
Single value · 3511, Oberfucha
pH 7,8 6,5–9,5 Single value · 3511, Oberfucha
Sodium 12 mg/l 200 mg/l
6 %
Single value · 3511, Oberfucha
Sulphate 27 mg/l 250 mg/l
11 %
Single value · 3511, Oberfucha

Further parameters (5)

Further parameters – 3511, Oberfucha
Parameter Value Parametric value Share of the parametric value Reference
Calcium 60 mg/l 400 mg/l
15 %
Single value · 3511, Oberfucha
Carbonate hardness 10 °dH Single value · 3511, Oberfucha
Magnesium 14 mg/l 150 mg/l
9 %
Single value · 3511, Oberfucha
Potassium 2,5 mg/l 50 mg/l
5 %
Single value · 3511, Oberfucha
Total hardness 11,6 °dH Single value · 3511, Oberfucha

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.evn.at/home/wasser/wasserwerte · 2026-01-28 · 2026-01-28 · retrieved on 08/07/2026

Postcodes in this zone: 3511

Frequently asked questions about drinking water in Furth bei Göttweig

How hard is the water in Furth bei Göttweig?
EVN Wasser GesmbH publishes a total hardness of 11.6 °dH for the supply zone 3511, Furth/Palt (hardness range medium). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2026-01-28, retrieved on 08/07/2026.
How much nitrate is in the drinking water in Furth bei Göttweig?
EVN Wasser GesmbH publishes a nitrate value of 5,5 mg/l for the supply zone 3511, Furth/Palt. The statutory parametric value is 50 mg/l; the measured value represents 11 % of the parametric value. Basis: 2026-01-28, retrieved on 08/07/2026.
Who supplies the drinking water in Furth bei Göttweig?
EVN Wasser GesmbH. The values shown here come from the supply zone 3511, Furth/Palt and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.