Skip to content
maunawai.info

Drinking water in Freienstein, Rorbas

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Druckzone Rorbas

Wasserversorgung Rorbas

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
24.7 °dH
Hardness range hard
Key values Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 22.58 mg/l 40 mg/l
56 %
Mean · Druckzone Rorbas
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Druckzone Rorbas
Sulphate 21.44 mg/l Mean · Druckzone Rorbas
Sodium 6.46 mg/l 200 mg/l
3 %
Mean · Druckzone Rorbas
Show all recorded parameters (20 — most recent value per parameter)

Microbiology (3)

Microbiology – Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 28 KBE/ml 300 1/ml Mean · Druckzone Rorbas
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Druckzone Rorbas
Intestinal enterococci 0 KBE/100ml 0/100 ml Maximum · Median 0 · Druckzone Rorbas

Chemical parameters (2)

Chemical parameters – Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Fluoride 0.11 mg/l 1.5 mg/l
7 %
Mean · Druckzone Rorbas
Nitrate 22.58 mg/l 40 mg/l
56 %
Mean · Druckzone Rorbas

Metabolites (2)

Metabolites – Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Chlorothalonil metabolite R417888 0.037 µg/l 0.1 µg/l
37 %
Mean · Druckzone Rorbas
Chlorothalonil metabolite R471811 0.38 µg/l 0.1 µg/l
380 % Mean above the parametric value
Mean · Druckzone Rorbas

Annual means and medians are not individual measured values, but the parametric values apply per sample. If a mean lies above it, at least one individual sample was above it — the mean does not say how many, or by how much. That is why this is not reported here as an exceedance of the parametric value. What counts remains the water supplier's publication, which each row links to.

Indicator parameters (7)

Indicator parameters – Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Chloride 10.8 mg/l Mean · Druckzone Rorbas
Conductivity (25 °C) 819 µS/cm Mean · Druckzone Rorbas
pH 7.23 Mean · Druckzone Rorbas
Sodium 6.46 mg/l 200 mg/l
3 %
Mean · Druckzone Rorbas
Sulphate 21.44 mg/l Mean · Druckzone Rorbas
Temperature 12.4 °C Mean · Druckzone Rorbas
Turbidity 0.1 TE/F Mean · Druckzone Rorbas

Further parameters (6)

Further parameters – Druckzone Rorbas
Parameter Value Parametric value Share of the parametric value Reference
Calcium 114.6 mg/l Mean · Druckzone Rorbas
Dissolved organic carbon (DOC) 0.43 mg/l Mean · Druckzone Rorbas
Magnesium 37.7 mg/l Mean · Druckzone Rorbas
Potassium 1.43 mg/l Mean · Druckzone Rorbas
Spectral absorption coefficient 254 nm (SAC 254) 0.83 1/m Mean · Druckzone Rorbas
Total hardness 44.1 °fH Mean · Druckzone Rorbas

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 8427

Show 1 more supply zone

Freienstein-Teufen

Freienstein-Teufen

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
18.5 °dH
Hardness range hard
Key values Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 15 mg/l 40 mg/l
38 %
Mean · Freienstein-Teufen
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Freienstein-Teufen
Sulphate 14 mg/l Mean · Freienstein-Teufen
Sodium 5 mg/l 200 mg/l
3 %
Mean · Freienstein-Teufen
Show all recorded parameters (19 — most recent value per parameter)

Microbiology (3)

Microbiology – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 18 KBE/ml 300 1/ml Mean · Freienstein-Teufen
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Freienstein-Teufen
Intestinal enterococci 0 KBE/100ml 0/100 ml Maximum · Median 0 · Freienstein-Teufen

Chemical parameters (2)

Chemical parameters – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Fluoride 0.1 mg/l 1.5 mg/l
7 %
Mean · Freienstein-Teufen
Nitrate 15 mg/l 40 mg/l
38 %
Mean · Freienstein-Teufen

PFAS (2)

PFAS – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Perfluorooctanesulfonic acid (PFOS) 0.001 µg/l 0.3 µg/l
0.3 %
Mean · Freienstein-Teufen
Perfluorooctanoic acid (PFOA) 0.001 µg/l 0.5 µg/l
0.2 %
Mean · Freienstein-Teufen

Metabolites (2)

Metabolites – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Chlorothalonil metabolite R417888 0.02 µg/l 0.1 µg/l
20 %
Mean · Freienstein-Teufen
Chlorothalonil metabolite R471811 0.06 µg/l 0.1 µg/l
60 %
Mean · Freienstein-Teufen

Indicator parameters (6)

Indicator parameters – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Chloride 5.9 mg/l Mean · Freienstein-Teufen
Conductivity (25 °C) 544 µS/cm Mean · Freienstein-Teufen
pH 7.4 Mean · Freienstein-Teufen
Sodium 5 mg/l 200 mg/l
3 %
Mean · Freienstein-Teufen
Sulphate 14 mg/l Mean · Freienstein-Teufen
Temperature 10 °C Mean · Freienstein-Teufen

Further parameters (4)

Further parameters – Freienstein-Teufen
Parameter Value Parametric value Share of the parametric value Reference
Calcium 98 mg/l Mean · Freienstein-Teufen
Magnesium 19 mg/l Mean · Freienstein-Teufen
Potassium 1 mg/l Mean · Freienstein-Teufen
Total hardness 33 °fH Mean · Freienstein-Teufen

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 8427

Frequently asked questions about drinking water in Freienstein, Rorbas

How hard is the water in Freienstein, Rorbas?
Wasserversorgung Rorbas publishes a total hardness of 44.1 °fH for the supply zone Druckzone Rorbas — that corresponds to 24.7 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2026, retrieved on 07/08/2026.
How much nitrate is in the drinking water in Freienstein, Rorbas?
Wasserversorgung Rorbas publishes a nitrate value of 22.58 mg/l for the supply zone Druckzone Rorbas. The statutory parametric value is 40 mg/l; the measured value represents 56 % of the parametric value. Basis: 2026, retrieved on 07/08/2026.
Who supplies the drinking water in Freienstein, Rorbas?
Wasserversorgung Rorbas. The values shown here come from the supply zone Druckzone Rorbas and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.