Skip to content
maunawai.info

Drinking water in Flachau

3 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; HB Flachau, Zulauf

Wasserverband Obere Enns

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 05/09/2023. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Key values WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; HB Flachau, Zulauf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) n.n. KBE/100ml
not detectable
0/100 ml Single value
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; HB Flachau, Zulauf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) n.n. KBE/100ml
not detectable
0/100 ml Single value
Intestinal enterococci n.n. KBE/100ml
not detectable
0/100 ml Single value

Indicator parameters (4)

Indicator parameters – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; HB Flachau, Zulauf
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria n.n. KBE/100ml
not detectable
0/100 ml Single value
Colony count 22 °C n.n. KBE/ml
not detectable
100 1/ml Single value
Colony count 36 °C n.n. KBE/ml
not detectable
20 1/ml Single value
Temperature 7,7 ± 0,2 °C Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.flachau.salzburg.at/system/web/GetDocument.ashx?cts=1697107506&fileId=1683747 · 03.10.2023 · 05.09.2023 · retrieved on 14/08/2026

Postcodes in this zone: 5542

Show 2 more supply zones

WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband

Wasserverband Obere Enns

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
8.4 °dH
Hardness range medium
Key values WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 1,31 mg/l 50 mg/l
3 %
Single value
Escherichia coli (E. coli) n.n. KBE/250ml
not detectable
0/100 ml Single value
Sulphate 11,6 mg/l 250 mg/l
5 %
Single value
Sodium <1 mg/l
below limit of quantification
200 mg/l
< 0.5 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (22 — most recent value per parameter)

Microbiology (3)

Microbiology – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) n.n. KBE/250ml
not detectable
0/100 ml Single value
Intestinal enterococci n.n. KBE/250ml
not detectable
0/100 ml Single value
Pseudomonas aeruginosa n.n. KBE/250ml
not detectable
0/100 ml Single value

Chemical parameters (2)

Chemical parameters – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 1,31 mg/l 50 mg/l
3 %
Single value
Nitrite <0,003 mg/l
below limit of quantification
0.1 mg/l
< 3 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (11)

Indicator parameters – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value
Chloride <1 mg/l
below limit of quantification
200 mg/l
< 0.5 % *
Single value
Clostridium perfringens (including spores) n.n. KBE/250ml
not detectable
0/100 ml Single value
Coliform bacteria n.n. KBE/250ml
not detectable
0/100 ml Single value
Colony count 22 °C n.n. KBE/ml
not detectable
100 1/ml Single value
Colony count 36 °C n.n. KBE/ml
not detectable
20 1/ml Single value
Conductivity (25 °C) 220 µS/cm 2,500 µS/cm Single value
pH 7,17 - 6,5–9,5 Single value
Sodium <1 mg/l
below limit of quantification
200 mg/l
< 0.5 % *
Single value
Sulphate 11,6 mg/l 250 mg/l
5 %
Single value
Turbidity 1,85 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (6)

Further parameters – WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; UV-Anlage Verband - PN nach UV Verband
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,49 mmol/l Single value
Calcium 35 mg/l 400 mg/l
9 %
Single value
Hydrogen carbonate 152 mg/l Single value
Magnesium 14,9 mg/l 150 mg/l
10 %
Single value
Potassium <1 mg/l
below limit of quantification
50 mg/l
< 2 % *
Single value
Total hardness 1,50 mmol/l Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.flachau.salzburg.at/system/web/GetDocument.ashx?cts=1767623336&fileId=2132609 · 22.12.2025 · Probenahme-Datum 02.12.2025, Bearb.-Zeitraum 02.-09.12.2025 · retrieved on 14/08/2026

Postcodes in this zone: 5542

Vor-Ort (Probenahme)

Wasserverband Obere Enns

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

No core values are available for this zone yet.

Show all recorded parameters (1 — most recent value per parameter)

Indicator parameters (1)

Indicator parameters – Vor-Ort (Probenahme)
Parameter Value Parametric value Share of the parametric value Reference
Temperature 5,8 °C Single value · Vor-Ort (Probenahme)

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.flachau.salzburg.at/system/web/GetDocument.ashx?cts=1767623336&fileId=2132609 · 22.12.2025 · Probenahme-Datum 02.12.2025, Bearb.-Zeitraum 02.-09.12.2025 · retrieved on 14/08/2026

Postcodes in this zone: 5542

Frequently asked questions about drinking water in Flachau

Who supplies the drinking water in Flachau?
Wasserverband Obere Enns. The values shown here come from the supply zone WV Obere Enns, Marbachquellen WBPZ 1403682/aufrecht; HB Flachau, Zulauf and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.