Skip to content
maunawai.info

Drinking water in Faistenau, Hintersee

One supply zone, water supplier: Full-Reuenthal.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Full-Reuenthal

Full-Reuenthal

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
14.2 °dH
Hardness range hard
Key values Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 15 mg/l 40 mg/l
38 %
Mean · Full-Reuenthal
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Full-Reuenthal
Show all recorded parameters (10 — most recent value per parameter)

Microbiology (3)

Microbiology – Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 0 KBE/ml 300 1/ml Mean · Full-Reuenthal
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Maximum · Median 0 · Full-Reuenthal
Intestinal enterococci 0 KBE/100ml 0/100 ml Maximum · Median 0 · Full-Reuenthal

Chemical parameters (1)

Chemical parameters – Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 15 mg/l 40 mg/l
38 %
Mean · Full-Reuenthal

Metabolites (2)

Metabolites – Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Chlorothalonil metabolite R417888 0.02 µg/l 0.1 µg/l
20 %
Mean · Full-Reuenthal
Chlorothalonil metabolite R471811 0.065 µg/l 0.1 µg/l
65 %
Mean · Full-Reuenthal

Indicator parameters (1)

Indicator parameters – Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Chloride 17.8 mg/l Mean · Full-Reuenthal

Further parameters (3)

Further parameters – Full-Reuenthal
Parameter Value Parametric value Share of the parametric value Reference
Calcium 80 mg/l Mean · Full-Reuenthal
Magnesium 12.2 mg/l Mean · Full-Reuenthal
Total hardness 25.4 °fH Mean · Full-Reuenthal

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://trinkwasser.ch/de/versorger/1395/full-reuenthal/3742/full-reuenthal · 2026 · 2026 · retrieved on 07/08/2026

Postcodes in this zone: 5324

Frequently asked questions about drinking water in Faistenau, Hintersee

How hard is the water in Faistenau, Hintersee?
Full-Reuenthal publishes a total hardness of 25.4 °fH for the supply zone Full-Reuenthal — that corresponds to 14.2 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2026, retrieved on 07/08/2026.
How much nitrate is in the drinking water in Faistenau, Hintersee?
Full-Reuenthal publishes a nitrate value of 15 mg/l for the supply zone Full-Reuenthal. The statutory parametric value is 40 mg/l; the measured value represents 38 % of the parametric value. Basis: 2026, retrieved on 07/08/2026.
Who supplies the drinking water in Faistenau, Hintersee?
Full-Reuenthal. The values shown here come from the supply zone Full-Reuenthal and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.