Skip to content
maunawai.info

Drinking water in Bludesch

3 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

NP OMV Tankstelle, Walgaustraße 68

Gemeindeamt Bludesch

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values NP OMV Tankstelle, Walgaustraße 68
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · NP OMV - Tankstelle, Walgaustraße 68
Show all recorded parameters (5 — most recent value per parameter)

Microbiology (2)

Microbiology – NP OMV Tankstelle, Walgaustraße 68
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · NP OMV - Tankstelle, Walgaustraße 68
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value · NP OMV - Tankstelle, Walgaustraße 68

Indicator parameters (3)

Indicator parameters – NP OMV Tankstelle, Walgaustraße 68
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100ml 0/100 ml Single value · NP OMV - Tankstelle, Walgaustraße 68
Colony count 22 °C 2 KBE/ml 100 1/ml Single value · NP OMV - Tankstelle, Walgaustraße 68
Colony count 36 °C 3 KBE/ml 20 1/ml Single value · NP OMV - Tankstelle, Walgaustraße 68

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.bludesch.at/site/assets/files/1043/ui-00038902026-tpb_as_akkr_amtssign_nebenproben.pdf · 27.05.2026 · Probenahme 31.03.2026; Analyse 31.03.2026 bis 13.04.2026 · retrieved on 11/08/2026

Postcodes in this zone: 6719

Show 2 more supply zones

NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1

Gemeindeamt Bludesch

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Show all recorded parameters (5 — most recent value per parameter)

Microbiology (2)

Microbiology – NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1

Indicator parameters (3)

Indicator parameters – NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100ml 0/100 ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Colony count 22 °C 4 KBE/ml 100 1/ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · NP Walgaukaserne, Brigadier-Herbert-Tschamon-Straße 1

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.bludesch.at/site/assets/files/1043/ui-00038902026-tpb_as_akkr_amtssign_nebenproben.pdf · 27.05.2026 · Probenahme 31.03.2026; Analyse 31.03.2026 bis 13.04.2026 · retrieved on 11/08/2026

Postcodes in this zone: 6719

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
18.9 °dH
Hardness range hard
Key values PW Gais
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 6.3 mg/l 50 mg/l
13 %
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 126 mg/l 250 mg/l
50 %
Single value
Sodium 5.1 mg/l 200 mg/l
3 %
Single value
Show all recorded parameters (18 — most recent value per parameter)

Microbiology (2)

Microbiology – PW Gais
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (2)

Chemical parameters – PW Gais
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 6.3 mg/l 50 mg/l
13 %
Single value
Nitrite <0.010 mg/l
below limit of quantification
0.1 mg/l
< 10 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (9)

Indicator parameters – PW Gais
Parameter Value Parametric value Share of the parametric value Reference
Ammonium <0.010 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value
Chloride 8.4 mg/l 200 mg/l
4 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml 100 1/ml Single value
Colony count 36 °C 0 KBE/ml 20 1/ml Single value
Iron <2.0 µg/l
below limit of quantification
0.2 mg/l
< 1 % *
Single value
Manganese <2.0 µg/l
below limit of quantification
50 µg/l
< 4 % *
Single value
Sodium 5.1 mg/l 200 mg/l
3 %
Single value
Sulphate 126 mg/l 250 mg/l
50 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (5)

Further parameters – PW Gais
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 4.63 mmol/l Single value
Calcium 95 mg/l 400 mg/l
24 %
Single value
Magnesium 24 mg/l 150 mg/l
16 %
Single value
Potassium 1.3 mg/l 50 mg/l
3 %
Single value
Total hardness 18.9 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.bludesch.at/site/assets/files/1043/ui-00039002026-tpb_as_akkr_amtssign.pdf · 27.05.2026 · Probenahme 31.03.2026, Analyse 31.03.2026 bis 13.04.2026 · retrieved on 11/08/2026

Postcodes in this zone: 6719

Frequently asked questions about drinking water in Bludesch

Who supplies the drinking water in Bludesch?
Gemeindeamt Bludesch. The values shown here come from the supply zone NP OMV Tankstelle, Walgaustraße 68 and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.