Skip to content
maunawai.info

Drinking water in Baumholder

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

No date is given for these values. The water supplier publishes the analysis without a sampling date and without a report date. When the water was examined is not apparent from the source — we do not add a date and we do not estimate one. What is stated is therefore only when we retrieved the document.

Key values Baumholder Nord
Parameter Value Parametric value Share of the parametric value Reference
Lead < 1 µg/L
below limit of quantification
10 µg/l
< 10 % *
Mean · Baumholder Nord
Escherichia coli (E. coli) 0 Anzahl/100ml 0/100 ml Mean · Baumholder Nord
Sulphate 14 mg/L 250 mg/l
6 %
Mean · Baumholder Nord
Sodium 7.4 mg/L 200 mg/l
4 %
Mean · Baumholder Nord

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (18 — most recent value per parameter)

Microbiology (1)

Microbiology – Baumholder Nord
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 Anzahl/100ml 0/100 ml Mean · Baumholder Nord

Chemical parameters (7)

Chemical parameters – Baumholder Nord
Parameter Value Parametric value Share of the parametric value Reference
Antimony 1 µg/L 5 µg/l
20 %
Mean · Baumholder Nord
Arsenic 2 µg/L 10 µg/l
20 %
Mean · Baumholder Nord
Cadmium < 1 µg/L
below limit of quantification
3 µg/l
< 33 % *
Mean · Baumholder Nord
Copper < 0.002 mg/L
below limit of quantification
2 mg/l
< 0.1 % *
Mean · Baumholder Nord
Lead < 1 µg/L
below limit of quantification
10 µg/l
< 10 % *
Mean · Baumholder Nord
Nickel < 2 µg/L
below limit of quantification
20 µg/l
< 10 % *
Mean · Baumholder Nord
Nitrite < 0.03 mg/L
below limit of quantification
0.5 mg/l
< 6 % *
Mean · Baumholder Nord

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (10)

Indicator parameters – Baumholder Nord
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0.02 mg/L
below limit of quantification
0.2 mg/l
< 10 % *
Mean · Baumholder Nord
Ammonium < 0.05 mg/L
below limit of quantification
0.5 mg/l
< 10 % *
Mean · Baumholder Nord
Chloride 9.5 mg/L 250 mg/l
4 %
Mean · Baumholder Nord
Coliform bacteria 0 Anzahl/100ml 0/100 ml Mean · Baumholder Nord
Iron < 0.001 mg/L
below limit of quantification
0.2 mg/l
< 0.5 % *
Mean · Baumholder Nord
Manganese < 0.005 mg/L
below limit of quantification
50 µg/l
< 10 % *
Mean · Baumholder Nord
pH 8.2 - 6,5–9,5 Mean · Baumholder Nord
Sodium 7.4 mg/L 200 mg/l
4 %
Mean · Baumholder Nord
Sulphate 14 mg/L 250 mg/l
6 %
Mean · Baumholder Nord
Temperature 9.5 °C Mean · Baumholder Nord

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://geodaten-wasser.rlp-umwelt.de/twist/2541695283/trinkwasserqualitaet · Mittelwerte · retrieved on 13/07/2026

Postcodes in this zone: 55774

Show 1 more supply zone

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

No date is given for these values. The water supplier publishes the analysis without a sampling date and without a report date. When the water was examined is not apparent from the source — we do not add a date and we do not estimate one. What is stated is therefore only when we retrieved the document.

Key values Baumholder Süd
Parameter Value Parametric value Share of the parametric value Reference
Lead < 1 µg/L
below limit of quantification
10 µg/l
< 10 % *
Mean · Baumholder Süd
Escherichia coli (E. coli) 0 Anzahl/100ml 0/100 ml Mean · Baumholder Süd
Sulphate 8.7 mg/L 250 mg/l
3 %
Mean · Baumholder Süd
Sodium 5 mg/L 200 mg/l
3 %
Mean · Baumholder Süd

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (18 — most recent value per parameter)

Microbiology (1)

Microbiology – Baumholder Süd
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 Anzahl/100ml 0/100 ml Mean · Baumholder Süd

Chemical parameters (7)

Chemical parameters – Baumholder Süd
Parameter Value Parametric value Share of the parametric value Reference
Antimony 1 µg/L 5 µg/l
20 %
Mean · Baumholder Süd
Arsenic 1 µg/L 10 µg/l
10 %
Mean · Baumholder Süd
Cadmium < 1 µg/L
below limit of quantification
3 µg/l
< 33 % *
Mean · Baumholder Süd
Copper < 0.002 mg/L
below limit of quantification
2 mg/l
< 0.1 % *
Mean · Baumholder Süd
Lead < 1 µg/L
below limit of quantification
10 µg/l
< 10 % *
Mean · Baumholder Süd
Nickel < 2 µg/L
below limit of quantification
20 µg/l
< 10 % *
Mean · Baumholder Süd
Nitrite < 0.03 mg/L
below limit of quantification
0.5 mg/l
< 6 % *
Mean · Baumholder Süd

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (10)

Indicator parameters – Baumholder Süd
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0.02 mg/L
below limit of quantification
0.2 mg/l
< 10 % *
Mean · Baumholder Süd
Ammonium < 0.05 mg/L
below limit of quantification
0.5 mg/l
< 10 % *
Mean · Baumholder Süd
Chloride 7.6 mg/L 250 mg/l
3 %
Mean · Baumholder Süd
Coliform bacteria 0 Anzahl/100ml 0/100 ml Mean · Baumholder Süd
Iron < 0.001 mg/L
below limit of quantification
0.2 mg/l
< 0.5 % *
Mean · Baumholder Süd
Manganese < 0.005 mg/L
below limit of quantification
50 µg/l
< 10 % *
Mean · Baumholder Süd
pH 8.3 - 6,5–9,5 Mean · Baumholder Süd
Sodium 5 mg/L 200 mg/l
3 %
Mean · Baumholder Süd
Sulphate 8.7 mg/L 250 mg/l
3 %
Mean · Baumholder Süd
Temperature 10.6 °C Mean · Baumholder Süd

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://geodaten-wasser.rlp-umwelt.de/twist/2541695130/trinkwasserqualitaet · Mittelwerte · retrieved on 13/07/2026

Postcodes in this zone: 55774

Frequently asked questions about drinking water in Baumholder

Who supplies the drinking water in Baumholder?
TWIST RLP - Baumholder Nord. The values shown here come from the supply zone Baumholder Nord and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.