Skip to content
maunawai.info

Drinking water in Appenweier

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Netz Appenweier / Entnahmestelle Rathaus Keller

Gemeinde Appenweier

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 14/05/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
12.3 °dH
Hardness range mittel
Key values Netz Appenweier / Entnahmestelle Rathaus Keller
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 19 mg/l 50 mg/l
38 %
Single value
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 21 mg/l 250 mg/l
8 %
Single value
Sodium 7,3 mg/l 200 mg/l
4 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (77 — most recent value per parameter)

Microbiology (2)

Microbiology – Netz Appenweier / Entnahmestelle Rathaus Keller
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (47)

Chemical parameters – Netz Appenweier / Entnahmestelle Rathaus Keller
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0,001 mg/l
below limit of quantification
3 µg/l
< 33 % *
Single value
2,6-Dichlorobenzamide (BAM) < 0,000025 mg/l
below limit of quantification
Single value
Antimony < 0,001 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Atrazine < 0,000025 mg/l
below limit of quantification
Single value
Bentazone < 0,000025 mg/l
below limit of quantification
Single value
Benzene < 0,0005 mg/l
below limit of quantification
1 µg/l
< 50 % *
Single value
Benzo(a)pyrene < 0,000005 mg/l
below limit of quantification
10 ng/l
< 50 % *
Single value
Benzo(b)fluoranthene < 0,00001 mg/l
below limit of quantification
Single value
Benzo(ghi)perylene < 0,00001 mg/l
below limit of quantification
Single value
Benzo(k)fluoranthene < 0,00001 mg/l
below limit of quantification
Single value
Bisphenol A < 0,00005 mg/l
below limit of quantification
2.5 µg/l
< 2 % *
Single value
Boron < 0,10 mg/l
below limit of quantification
1 mg/l
< 10 % *
Single value
Bromate < 0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Bromodichloromethane < 0,001 mg/l
below limit of quantification
Single value
Cadmium < 0,0003 mg/l
below limit of quantification
3 µg/l
< 10 % *
Single value
Chromium 0,0005 mg/l 25 µg/l
2 %
Single value
Copper 0,008 mg/l 2 mg/l
0.4 %
Single value
Cyanide < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Desethylatrazine < 0,000025 mg/l
below limit of quantification
Single value
Desethylterbuthylazine < 0,000025 mg/l
below limit of quantification
Single value
Desisopropylatrazine < 0,000025 mg/l
below limit of quantification
Single value
Dibromochloromethane < 0,001 mg/l
below limit of quantification
Single value
Fluoride < 0,1 mg/l
below limit of quantification
1.5 mg/l
< 7 % *
Single value
Hexazinone < 0,000025 mg/l
below limit of quantification
Single value
Indeno(1,2,3-cd)pyrene < 0,00001 mg/l
below limit of quantification
Single value
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Mercury < 0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value
Metalaxyl < 0,000025 mg/l
below limit of quantification
Single value
Metazachlor < 0,000025 mg/l
below limit of quantification
Single value
Metolachlor < 0,000025 mg/l
below limit of quantification
Single value
Nickel < 0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value
Nitrate 19 mg/l 50 mg/l
38 %
Single value
Nitrite < 0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value
Polycyclic aromatic hydrocarbons < 0,00001 mg/l
below limit of quantification
0.1 µg/l
< 10 % *
Single value
Propazine < 0,000025 mg/l
below limit of quantification
Single value
Selenium < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Simazine < 0,000025 mg/l
below limit of quantification
Single value
Terbuthylazine < 0,000025 mg/l
below limit of quantification
Single value
Tetrachloroethene < 0,001 mg/l
below limit of quantification
Single value
Tetrachloroethene and Trichloroethene (sum) < 0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Tribromomethane (bromoform) < 0,001 mg/l
below limit of quantification
Single value
Trichloroethene < 0,001 mg/l
below limit of quantification
Single value
Trichloromethane (chloroform) < 0,001 mg/l
below limit of quantification
Single value
Trihalomethanes — Total < 0,001 mg/l
below limit of quantification
50 µg/l
< 2 % *
Single value
Uranium < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Vinyl chloride < 0,0005 mg/l
below limit of quantification
0.5 µg/l
< 100 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (19)

Indicator parameters – Netz Appenweier / Entnahmestelle Rathaus Keller
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Ammonium < 0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Calcite dissolution capacity -5,7 mg/l 5 mg/l CaCO3 Single value
Chloride 12 mg/l 250 mg/l
5 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Colour < 0,1 1/m
below limit of quantification
0.5 m⁻¹ Single value
Conductivity (25 °C) 466 µS/cm 2,790 µS/cm Single value
Iron < 0,02 mg/l
below limit of quantification
0.2 mg/l
< 10 % *
Single value
Manganese < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Odour ohne für den Verbraucher annehmbar Single value
pH 7,53 6,5–9,5 Single value
Sodium 7,3 mg/l 200 mg/l
4 %
Single value
Sulphate 21 mg/l 250 mg/l
8 %
Single value
Taste ohne für den Verbraucher annehmbar Single value
Temperature 12,2 °C Single value
Total organic carbon (TOC) < 0,50 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity 0,04 NTU 1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (9)

Further parameters – Netz Appenweier / Entnahmestelle Rathaus Keller
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 3,71 mmol/l Single value
Base capacity to pH 8.2 0,23 mmol/l Single value
Calcium 71 mg/l Single value
Hardness range (WRMG) mittel Single value
Magnesium 11 mg/l Single value
Oxygen 10,4 mg O2/l Single value
Potassium 2,5 mg/l Single value
Saturation index 7,48 Single value
Total hardness 2,2 mmol/l Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.appenweier.de/de/cityweb/dokumente/Wasseranalysen/wasseranalyse20240514.pdf · 14.05.2024 · Einzelprobe (Stichprobe) vom 2024-04-03, Untersuchungsende 2024-05-14 · retrieved on 08/08/2026

Postcodes in this zone: 77767

Show 1 more supply zone

Netz Appenweier - Rathaus Keller

Gemeinde Appenweier

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

No core values are available for this zone yet.

Postcodes in this zone: 77767

Frequently asked questions about drinking water in Appenweier

How hard is the water in Appenweier?
Gemeinde Appenweier publishes a total hardness of 2,2 mmol/l for the supply zone Netz Appenweier / Entnahmestelle Rathaus Keller — that corresponds to 12.3 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 14.05.2024, retrieved on 08/08/2026.
How much nitrate is in the drinking water in Appenweier?
Gemeinde Appenweier publishes a nitrate value of 19 mg/l for the supply zone Netz Appenweier / Entnahmestelle Rathaus Keller. The statutory parametric value is 50 mg/l; the measured value represents 38 % of the parametric value. Basis: 14.05.2024, retrieved on 08/08/2026.
Who supplies the drinking water in Appenweier?
Gemeinde Appenweier. The values shown here come from the supply zone Netz Appenweier / Entnahmestelle Rathaus Keller and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.