Skip to content
maunawai.info

Drinking water in Adliswil

2 supply zones — values can differ depending on the district. Below is the zone with the most documented parameters, the others collapsed underneath. To determine the exact match, look up the postcode.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
14.6 °dH
Hardness range hard
Key values obere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 9.75 mg/l 40 mg/l
24 %
Mean · obere Druckzone
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · obere Druckzone
Show all recorded parameters (7 — most recent value per parameter)

Microbiology (3)

Microbiology – obere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 58.4 KBE/ml 300 1/ml Mean · obere Druckzone
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · obere Druckzone
Intestinal enterococci nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · obere Druckzone

Chemical parameters (1)

Chemical parameters – obere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 9.75 mg/l 40 mg/l
24 %
Mean · obere Druckzone

Further parameters (3)

Further parameters – obere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Calcium 3.58 mg/l Mean · obere Druckzone
Magnesium 1.09 mg/l Mean · obere Druckzone
Total hardness 26 °fH Mean · obere Druckzone

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 8134

Show 1 more supply zone

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
14.7 °dH
Hardness range hard
Key values untere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 6.37 mg/l 40 mg/l
16 %
Mean · untere Druckzone
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · untere Druckzone
Show all recorded parameters (7 — most recent value per parameter)

Microbiology (3)

Microbiology – untere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Aerobic mesophilic bacteria 50 KBE/ml 300 1/ml Mean · untere Druckzone
Escherichia coli (E. coli) nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · untere Druckzone
Intestinal enterococci nn
not detectable
Unit not stated in the document
0/100 ml Maximum · Median nn · untere Druckzone

Chemical parameters (1)

Chemical parameters – untere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 6.37 mg/l 40 mg/l
16 %
Mean · untere Druckzone

Further parameters (3)

Further parameters – untere Druckzone
Parameter Value Parametric value Share of the parametric value Reference
Calcium 3.74 mg/l Mean · untere Druckzone
Magnesium 1 mg/l Mean · untere Druckzone
Total hardness 26.3 °fH Mean · untere Druckzone

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Postcodes in this zone: 8134

Frequently asked questions about drinking water in Adliswil

How hard is the water in Adliswil?
Wasserversorgung Adliswil publishes a total hardness of 26 °fH for the supply zone obere Druckzone — that corresponds to 14.6 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 2025, retrieved on 07/08/2026.
How much nitrate is in the drinking water in Adliswil?
Wasserversorgung Adliswil publishes a nitrate value of 9.75 mg/l for the supply zone obere Druckzone. The statutory parametric value is 40 mg/l; the measured value represents 24 % of the parametric value. Basis: 2025, retrieved on 07/08/2026.
Who supplies the drinking water in Adliswil?
Wasserversorgung Adliswil. The values shown here come from the supply zone obere Druckzone and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.