Skip to content
maunawai.info

Drinking water in 96482

One supply zone, water supplier: Gemeindewerke Ahorn.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Ahorn, Coburger Straße 16, Drucksteigerungspumpe

Gemeindewerke Ahorn

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
6.2 °dH
Hardness range soft
Key values Ahorn, Coburger Straße 16, Drucksteigerungspumpe
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 7,0 mg/l 50 mg/l
14 %
Single value
Lead < 0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 15 mg/l 250 mg/l
6 %
Single value
Sodium 7,2 mg/l 200 mg/l
4 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (83 — most recent value per parameter)

Microbiology (2)

Microbiology – Ahorn, Coburger Straße 16, Drucksteigerungspumpe
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (54)

Chemical parameters – Ahorn, Coburger Straße 16, Drucksteigerungspumpe
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0,0003 mg/l
below limit of quantification
3 µg/l
< 10 % *
Single value
2,6-Dichlorobenzamide (BAM) < 0,00002 mg/l
below limit of quantification
Single value
Acrylamide nicht erforderlich, da keine Polymeranwendung mg/l
not determined
0.1 µg/l Single value
Antimony < 0,001 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic < 0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Atrazine < 0,00002 mg/l
below limit of quantification
Single value
Benzene < 0,0002 mg/l
below limit of quantification
1 µg/l
< 20 % *
Single value
Benzo(a)pyrene < 0,000003 mg/l
below limit of quantification
10 ng/l
< 30 % *
Single value
Benzo(b)fluoranthene < 0,00001 mg/l
below limit of quantification
Single value
Benzo(ghi)perylene < 0,00001 mg/l
below limit of quantification
Single value
Benzo(k)fluoranthene < 0,00001 mg/l
below limit of quantification
Single value
Bisphenol A < 0,000005 mg/l
below limit of quantification
2.5 µg/l
< 0.2 % *
Single value
Boron < 0,05 mg/l
below limit of quantification
1 mg/l
< 5 % *
Single value
Bromate < 0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Bromodichloromethane 0,0036 mg/l Single value
Cadmium < 0,0002 mg/l
below limit of quantification
3 µg/l
< 7 % *
Single value
Chlorate 0,04 mg/l 70 µg/l
57 %
Single value
Chlorite nicht erforderlich, da keine Desinfektion mit Chloritbildung mg/l
not determined
0.2 mg/l Single value
Chlorotoluron < 0,00002 mg/l
below limit of quantification
Single value
Chromium < 0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value
Copper < 0,010 mg/l
below limit of quantification
2 mg/l
< 0.5 % *
Single value
Cyanide < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Desethylatrazine < 0,00002 mg/l
below limit of quantification
Single value
Desisopropylatrazine < 0,00002 mg/l
below limit of quantification
Single value
Dibromoacetic acid < 0,001 mg/l
below limit of quantification
Single value
Dibromochloromethane 0,0012 mg/l Single value
Dichloroacetic acid < 0,001 mg/l
below limit of quantification
Single value
Diuron < 0,00002 mg/l
below limit of quantification
Single value
Epichlorohydrin nicht erforderlich, da keine Anwendung von Epoxidharzen mg/l
not determined
0.1 µg/l Single value
Fluoride < 0,10 mg/l
below limit of quantification
1.5 mg/l
< 7 % *
Single value
Indeno(1,2,3-cd)pyrene < 0,00001 mg/l
below limit of quantification
Single value
Isoproturon < 0,00002 mg/l
below limit of quantification
Single value
Lead < 0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Mercury < 0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value
Metazachlor < 0,00002 mg/l
below limit of quantification
Single value
Metolachlor < 0,00002 mg/l
below limit of quantification
Single value
Monobromoacetic acid < 0,001 mg/l
below limit of quantification
Single value
Monochloroacetic acid < 0,001 mg/l
below limit of quantification
Single value
Nickel < 0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value
Nitrate 7,0 mg/l 50 mg/l
14 %
Single value
Nitrite < 0,030 mg/l
below limit of quantification
0.5 mg/l
< 6 % *
Single value
Polycyclic aromatic hydrocarbons < BG mg/l
not detectable
0.1 µg/l Single value
Propazine < 0,00002 mg/l
below limit of quantification
Single value
Selenium < 0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Simazine < 0,00002 mg/l
below limit of quantification
Single value
Terbuthylazine < 0,00002 mg/l
below limit of quantification
Single value
Tetrachloroethene < 0,00005 mg/l
below limit of quantification
Single value
Tribromomethane (bromoform) < 0,0002 mg/l
below limit of quantification
Single value
Trichloroacetic acid < 0,001 mg/l
below limit of quantification
Single value
Trichloroethene < 0,00005 mg/l
below limit of quantification
Single value
Trichloromethane (chloroform) 0,0073 mg/l Single value
Trihalomethanes — Total 0,0121 mg/l 50 µg/l
24 %
Single value
Uranium < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Vinyl chloride < 0,0002 mg/l
below limit of quantification
0.5 µg/l
< 40 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (17)

Indicator parameters – Ahorn, Coburger Straße 16, Drucksteigerungspumpe
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,020 mg/l
below limit of quantification
0.2 mg/l
< 10 % *
Single value
Ammonium < 0,025 mg/l
below limit of quantification
0.5 mg/l
< 5 % *
Single value
Chloride 9,4 mg/l 250 mg/l
4 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Colour farblos - 0.5 m⁻¹ Single value
Iron < 0,010 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Odour ohne Befund - für den Verbraucher annehmbar Single value
pH 8,27 - 6,5–9,5 Single value
Sodium 7,2 mg/l 200 mg/l
4 %
Single value
Sulphate 15 mg/l 250 mg/l
6 %
Single value
Taste nicht bestimmt -
not determined
für den Verbraucher annehmbar Single value
Temperature 9,2 °C Single value
Total organic carbon (TOC) 1,5 mg/l ohne anormale Veränderung Single value
Turbidity klar - 1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (10)

Further parameters – Ahorn, Coburger Straße 16, Drucksteigerungspumpe
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 1,8 mmol/l Single value
Acid capacity to pH 8.2 < 0,10 mmol/l
below limit of quantification
Single value
Base capacity to pH 8.2 entfällt mmol/l
not determined
Single value
Calcium 40 mg/l Single value
Carbonate hardness 5,2 °dH Single value
Hydrogen carbonate 112 mg/l Single value
Magnesium 2,4 mg/l Single value
Oxygen 9,6 mg/l Single value
Potassium 0,8 mg/l Single value
Total hardness 6,2 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.ahorn.de/verwaltung-politik/ver-und-entsorgung/gemeindewerke/trinkwasseranalyse-2026.pdf?cid=d17 · Stand: 20.06.2023 · Untersuchungszeitraum 17.12.2025 - 12.01.2026 · retrieved on 11/07/2026

Frequent questions about postcode 96482

How hard is the water in Postcode 96482?
Gemeindewerke Ahorn publishes a total hardness of 6.2 °dH for the supply zone Ahorn, Coburger Straße 16, Drucksteigerungspumpe (hardness range soft). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Stand: 20.06.2023, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 96482?
Gemeindewerke Ahorn publishes a nitrate value of 7,0 mg/l for the supply zone Ahorn, Coburger Straße 16, Drucksteigerungspumpe. The statutory parametric value is 50 mg/l; the measured value represents 14 % of the parametric value. Basis: Stand: 20.06.2023, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 96482?
Gemeindewerke Ahorn. The values shown here come from the supply zone Ahorn, Coburger Straße 16, Drucksteigerungspumpe and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.