Skip to content
maunawai.info

Drinking water in 95659

One supply zone, water supplier: Arzberg.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

arzberg gesamt

Arzberg

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 30/06/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Key values arzberg gesamt
Parameter Value Parametric value Share of the parametric value Reference
Lead < 0,0005 mg/l
below limit of quantification
10 µg/l
< 5 % *
Single value
Sulphate 110 mg/l 250 mg/l
44 %
Single value
Sodium 21,7 mg/l 200 mg/l
11 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (12 — most recent value per parameter)

Chemical parameters (3)

Chemical parameters – arzberg gesamt
Parameter Value Parametric value Share of the parametric value Reference
Copper n.n. mg/l
not detectable
2 mg/l Single value
Lead < 0,0005 mg/l
below limit of quantification
10 µg/l
< 5 % *
Single value
Nitrite n.n. mg/l
not detectable
0.5 mg/l Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (8)

Indicator parameters – arzberg gesamt
Parameter Value Parametric value Share of the parametric value Reference
Calcite dissolution capacity 0,2 mg/l 5 mg/l CaCO3 Single value
Chloride 38 mg/l 250 mg/l
15 %
Single value
Conductivity (25 °C) 516 μS/cm 2,790 µS/cm Single value
Iron < 0,035 mg/l
below limit of quantification
0.2 mg/l
< 18 % *
Single value
Manganese < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
pH 7,8 6,5–9,5 Single value
Sodium 21,7 mg/l 200 mg/l
11 %
Single value
Sulphate 110 mg/l 250 mg/l
44 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (1)

Further parameters – arzberg gesamt
Parameter Value Parametric value Share of the parametric value Reference
Total hardness 11,1 = Härtebereich 2 "mittel" °dh Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.tazv-beilrode.de/wasserwerte · Messung vom 30.06.2024 · retrieved on 13/07/2026

Frequent questions about postcode 95659

Who supplies the drinking water in Postcode 95659?
Arzberg. The values shown here come from the supply zone arzberg gesamt and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.