Skip to content
maunawai.info

Drinking water in 92637

One supply zone, water supplier: Stadtwerke Weiden i.d.OPf. AdöR.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)

Stadtwerke Weiden i.d.OPf. AdöR

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
9 °dH
Hardness range medium
Key values Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
Sum of PFAS <0,040 µg/l
below limit of quantification
0.1 µg/l
< 40 % *
Single value
Nitrate 8,93 mg/l 50 mg/l
18 %
Single value
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value
Sulphate 29 mg/l 250 mg/l
12 %
Single value
Sodium 3,38 mg/l 200 mg/l
2 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (126 — most recent value per parameter)

Microbiology (2)

Microbiology – Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value

Chemical parameters (75)

Chemical parameters – Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,3 µg/l
below limit of quantification
3 µg/l
< 10 % *
Single value
2,4-D <0,02 µg/l
below limit of quantification
Single value
Antimony <0,001 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Atrazine <0,02 µg/l
below limit of quantification
Single value
Azoxystrobin <0,02 µg/l
below limit of quantification
Single value
Bentazone <0,02 µg/l
below limit of quantification
Single value
Benzene <0,3 µg/l
below limit of quantification
1 µg/l
< 30 % *
Single value
Benzo(a)pyrene <0,002 µg/l
below limit of quantification
10 ng/l
< 20 % *
Single value
Benzo(b)fluoranthene <0,01 µg/l
below limit of quantification
Single value
Benzo(ghi)perylene <0,01 µg/l
below limit of quantification
Single value
Benzo(k)fluoranthene <0,01 µg/l
below limit of quantification
Single value
Bisphenol A <0,05 µg/l
below limit of quantification
2.5 µg/l
< 2 % *
Single value
Boron <0,010 mg/l
below limit of quantification
1 mg/l
< 1 % *
Single value
Boscalid <0,02 µg/l
below limit of quantification
Single value
Bromacil <0,02 µg/l
below limit of quantification
Single value
Bromate <0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Bromoxynil <0,02 µg/l
below limit of quantification
Single value
Cadmium <0,0001 mg/l
below limit of quantification
3 µg/l
< 3 % *
Single value
Carbendazim <0,02 µg/l
below limit of quantification
Single value
Carbetamide <0,02 µg/l
below limit of quantification
Single value
Chloridazon <0,02 µg/l
below limit of quantification
Single value
Chlorotoluron <0,02 µg/l
below limit of quantification
Single value
Chromium 0,00081 mg/l 25 µg/l
3 %
Single value
Clopyralid <0,05 µg/l
below limit of quantification
Single value
Copper <0,001 mg/l
below limit of quantification
2 mg/l
< < 0.1 % *
Single value
Cyanide <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Desethylatrazine <0,02 µg/l
below limit of quantification
Single value
Dicamba <0,02 µg/l
below limit of quantification
Single value
Dichlorprop <0,02 µg/l
below limit of quantification
Single value
Diflufenican <0,02 µg/l
below limit of quantification
Single value
Dimefuron <0,02 µg/l
below limit of quantification
Single value
Dimethachlor <0,02 µg/l
below limit of quantification
Single value
Dimethenamid <0,02 µg/l
below limit of quantification
Single value
Dimethoate <0,02 µg/l
below limit of quantification
Single value
Diuron <0,02 µg/l
below limit of quantification
Single value
Ethidimuron <0,02 µg/l
below limit of quantification
Single value
Ethofumesate <0,02 µg/l
below limit of quantification
Single value
Flufenacet <0,02 µg/l
below limit of quantification
Single value
Fluoride 0,071 mg/l 1.5 mg/l
5 %
Single value
Glyphosate <0,05 µg/l
below limit of quantification
Single value
Imidacloprid <0,02 µg/l
below limit of quantification
Single value
Indeno(1,2,3-cd)pyrene <0,01 µg/l
below limit of quantification
Single value
Isoproturon <0,02 µg/l
below limit of quantification
Single value
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Lenacil <0,02 µg/l
below limit of quantification
Single value
MCPA <0,02 µg/l
below limit of quantification
Single value
Mecoprop <0,02 µg/l
below limit of quantification
Single value
Mercury <0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value
Metalaxyl <0,02 µg/l
below limit of quantification
Single value
Metamitron <0,02 µg/l
below limit of quantification
Single value
Metazachlor <0,02 µg/l
below limit of quantification
Single value
Metobromuron <0,02 µg/l
below limit of quantification
Single value
Metolachlor <0,02 µg/l
below limit of quantification
Single value
Metribuzin <0,02 µg/l
below limit of quantification
Single value
Nickel <0,001 mg/l
below limit of quantification
20 µg/l
< 5 % *
Single value
Nicosulfuron <0,02 µg/l
below limit of quantification
Single value
Nitrate 8,93 mg/l 50 mg/l
18 %
Single value
Nitrite <0,005 mg/l
below limit of quantification
0.5 mg/l
< 1 % *
Single value
Pendimethalin <0,02 µg/l
below limit of quantification
Single value
Pesticides — Total --- µg/l
not determined
0.5 µg/l Single value
Propazine <0,02 µg/l
below limit of quantification
Single value
Propiconazole <0,02 µg/l
below limit of quantification
Single value
Prosulfocarb <0,02 µg/l
below limit of quantification
Single value
Quinmerac <0,02 µg/l
below limit of quantification
Single value
Selenium <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Simazine <0,02 µg/l
below limit of quantification
Single value
Tebuconazole <0,02 µg/l
below limit of quantification
Single value
Terbuthylazine <0,02 µg/l
below limit of quantification
Single value
Tetrachloroethene <0,1 µg/l
below limit of quantification
Single value
Tetrachloroethene and Trichloroethene (sum) -- µg/l
not determined
10 µg/l Single value
Thiacloprid <0,02 µg/l
below limit of quantification
Single value
Triadimenol <0,02 µg/l
below limit of quantification
Single value
Trichloroethene <1 µg/l
below limit of quantification
Single value
Uranium 0,004 mg/l 10 µg/l
40 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

PFAS (22)

PFAS – Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
Perfluorobutane sulfonic acid (PFBS) <0,001 µg/l
below limit of quantification
Single value
Perfluorobutanoic acid (PFBA) <0,001 µg/l
below limit of quantification
Single value
Perfluorodecane sulfonic acid (PFDS) <0,001 µg/l
below limit of quantification
Single value
Perfluorodecanoic acid (PFDA) <0,001 µg/l
below limit of quantification
Single value
Perfluorododecane sulfonic acid (PFDoDS) <0,005 µg/l
below limit of quantification
Single value
Perfluorododecanoic acid (PFDoDA) <0,001 µg/l
below limit of quantification
Single value
Perfluoroheptane sulfonic acid (PFHpS) <0,001 µg/l
below limit of quantification
Single value
Perfluoroheptanoic acid (PFHpA) <0,001 µg/l
below limit of quantification
Single value
Perfluorohexane sulfonic acid (PFHxS) <0,001 µg/l
below limit of quantification
Single value
Perfluorohexanoic acid (PFHxA) <0,001 µg/l
below limit of quantification
Single value
Perfluorononane sulfonic acid (PFNS) <0,005 µg/l
below limit of quantification
Single value
Perfluorononanoic acid (PFNA) <0,001 µg/l
below limit of quantification
Single value
Perfluorooctanesulfonic acid (PFOS) <0,001 µg/l
below limit of quantification
Single value
Perfluorooctanoic acid (PFOA) <0,001 µg/l
below limit of quantification
Single value
Perfluoropentanesulfonic acid (PFPeS) <0,001 µg/l
below limit of quantification
Single value
Perfluoropentanoic acid (PFPeA) <0,001 µg/l
below limit of quantification
Single value
Perfluorotridecanesulfonic acid (PFTrDS) <0,005 µg/l
below limit of quantification
Single value
Perfluorotridecanoic acid (PFTrDA) <0,005 µg/l
below limit of quantification
Single value
Perfluoroundecanesulfonic acid (PFUnDS) <0,005 µg/l
below limit of quantification
Single value
Perfluoroundecanoic acid (PFUnDA) <0,001 µg/l
below limit of quantification
Single value
Sum of 4 PFAS <0,004 µg/l
below limit of quantification
Single value
Sum of PFAS <0,040 µg/l
below limit of quantification
0.1 µg/l
< 40 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (18)

Indicator parameters – Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,005 mg/l
below limit of quantification
0.2 mg/l
< 3 % *
Single value
Ammonium 0,023 mg/l 0.5 mg/l
5 %
Single value
Calcite dissolution capacity -0,9 mg/l 5 mg/l CaCO3 Single value
Chloride 13,3 mg/l 250 mg/l
5 %
Single value
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Conductivity (25 °C) 349 µS/cm 2,790 µS/cm Single value
Iron <0,010 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese <0,003 mg/l
below limit of quantification
50 µg/l
< 6 % *
Single value
Odour ohne -- für den Verbraucher annehmbar Single value
pH 8,0 -- 6,5–9,5 Single value
Sodium 3,38 mg/l 200 mg/l
2 %
Single value
Sulphate 29 mg/l 250 mg/l
12 %
Single value
Taste ohne -- für den Verbraucher annehmbar Single value
Temperature 7,3 °C Single value
Total organic carbon (TOC) <0,50 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity <0,05 FNU
below limit of quantification
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (9)

Further parameters – Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,44 mmol/l Single value
Acid capacity to pH 8.2 --- mmol/l
not determined
Single value
Base capacity to pH 8.2 <0,100 mmol/l
below limit of quantification
Single value
Calcium 39,5 mg/l Single value
Copper quotient 7,90 -- Single value
Magnesium 15,0 mg/l Single value
Phosphate 0,039 mg/l Single value
Potassium 6,31 mg/l Single value
Total hardness 9,0 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.stadtwerke-weiden.de/_Resources/Persistent/9/3/4/4/9344b71311c3fb2e71c07d1fa9e5866c6116e35a/Wasseranalyse.pdf · 24.03.2026 · Probenahme 03.03.2026, Prüfzeitraum 03.03.2026 - 24.03.2026 · retrieved on 11/07/2026

Frequent questions about postcode 92637

How hard is the water in Postcode 92637?
Stadtwerke Weiden i.d.OPf. AdöR publishes a total hardness of 9 °dH for the supply zone Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3) (hardness range medium). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 24.03.2026, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 92637?
Stadtwerke Weiden i.d.OPf. AdöR publishes a nitrate value of 8,93 mg/l for the supply zone Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3). The statutory parametric value is 50 mg/l; the measured value represents 18 % of the parametric value. Basis: 24.03.2026, retrieved on 11/07/2026.
Are PFAS detectable in the drinking water in Postcode 92637?
Stadtwerke Weiden i.d.OPf. AdöR publishes for the supply zone Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3) a sum value PFAS-20 below the limit of quantification (entry in the report: "<0,040 µg/l"). This is not to be read as "PFAS-free": below the limit of quantification, the measurement cannot make any statement. The statutory parametric value is 0.1 µg/l; the measured value lies below it and cannot be specified more precisely below the limit of quantification. For the sum of the 20 individual substances, this parametric value has applied since 12/01/2026. Basis: 24.03.2026, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 92637?
Stadtwerke Weiden i.d.OPf. AdöR. The values shown here come from the supply zone Öffentliche WV Weiden, HB 3, gesamt rein (Probenahmeort: HB 3) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.