One supply zone, water supplier: ZV Wasserversorgung Sengenthal - Deining.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Sengenthal (Probe: Rathaus Deining)

ZV Wasserversorgung Sengenthal - Deining

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
10.1 °dH
Hardness range mittel
Key values Sengenthal (Probe: Rathaus Deining)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 2,2 mg/l 50 mg/l
4 %
Single value
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Escherichia coli (E. coli) 0 1/100ml 0/100 ml Single value
Sulphate 44 mg/l 250 mg/l
18 %
Single value
Sodium 4,7 mg/l 200 mg/l
2 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (62 — most recent value per parameter)

Microbiology (2)

Microbiology – Sengenthal (Probe: Rathaus Deining)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 1/100ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100ml 0/100 ml Single value

Chemical parameters (30)

Chemical parameters – Sengenthal (Probe: Rathaus Deining)
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,2 µg/l
below limit of quantification
3 µg/l
< 7 % *
Single value
Acrylamide <0,03 µg/l
below limit of quantification
0.1 µg/l
< 30 % *
Single value
Antimony <0,001 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic 0,001 mg/l 10 µg/l
10 %
Single value
Benzene <0,2 µg/l
below limit of quantification
1 µg/l
< 20 % *
Single value
Benzo(a)pyrene <0,001 µg/l
below limit of quantification
10 ng/l
< 10 % *
Single value
Benzo(b)fluoranthene <0,002 µg/l
below limit of quantification
Single value
Benzo(ghi)perylene <0,002 µg/l
below limit of quantification
Single value
Benzo(k)fluoranthene <0,002 µg/l
below limit of quantification
Single value
Bisphenol A <0,4 µg/l
below limit of quantification
2.5 µg/l
< 16 % *
Single value
Boron <0,02 mg/l
below limit of quantification
1 mg/l
< 2 % *
Single value
Bromate <0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Cadmium <0,0001 mg/l
below limit of quantification
3 µg/l
< 3 % *
Single value
Chromium <0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value
Copper 0,01 mg/l 2 mg/l
0.5 %
Single value
Cyanide <0,002 mg/l
below limit of quantification
50 µg/l
< 4 % *
Single value
Epichlorohydrin <0,03 µg/l
below limit of quantification
0.1 µg/l
< 30 % *
Single value
Fluoride 0,12 mg/l 1.5 mg/l
8 %
Single value
Indeno(1,2,3-cd)pyrene <0,002 µg/l
below limit of quantification
Single value
Lead <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Mercury <0,00003 mg/l
below limit of quantification
1 µg/l
< 3 % *
Single value
Nickel <0,002 mg/l
below limit of quantification
20 µg/l
< 10 % *
Single value
Nitrate 2,2 mg/l 50 mg/l
4 %
Single value
Nitrite <0,030 mg/l
below limit of quantification
0.5 mg/l
< 6 % *
Single value
Polycyclic aromatic hydrocarbons n.n. µg/l
not detectable
0.1 µg/l Single value
Selenium <0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Tetrachloroethene <0,2 µg/l
below limit of quantification
Single value
Trichloroethene <0,2 µg/l
below limit of quantification
Single value
Uranium <0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Vinyl chloride <0,15 µg/l
below limit of quantification
0.5 µg/l
< 30 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (17)

Indicator parameters – Sengenthal (Probe: Rathaus Deining)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,02 mg/l
below limit of quantification
0.2 mg/l
< 10 % *
Single value
Ammonium <0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Calcite dissolution capacity -3,0 mg/l 5 mg/l CaCO3 Single value
Chloride 14 mg/l 250 mg/l
6 %
Single value
Coliform bacteria 0 1/100ml 0/100 ml Single value
Colony count 22 °C 0 1/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 1/ml ohne anormale Veränderung Single value
Colour farblos
Unit not stated in the document
0.5 m⁻¹ Single value
Conductivity (25 °C) 378 µS/cm 2,790 µS/cm Single value
Odour ohne für den Verbraucher annehmbar Single value
pH 7,8 6,5–9,5 Single value
Sodium 4,7 mg/l 200 mg/l
2 %
Single value
Sulphate 44 mg/l 250 mg/l
18 %
Single value
Taste ohne für den Verbraucher annehmbar Single value
Temperature 6,7 °C Single value
Total organic carbon (TOC) 0,91 mg/l ohne anormale Veränderung Single value
Turbidity klar
Unit not stated in the document
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (13)

Further parameters – Sengenthal (Probe: Rathaus Deining)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,5 mmol/l Single value
Base capacity to pH 8.2 <0,10 mmol/l
below limit of quantification
Single value
Calcium 63 mg/l Single value
Copper quotient 5,45 Single value
Hardness range (WRMG) mittel Single value
Magnesium 5,6 mg/l Single value
Phosphate <0,03 mg/l
below limit of quantification
Single value
Pitting corrosion quotient S1 0,539 Single value
Potassium 2,2 mg/l Single value
Sum of anion equivalents 3,8 mval/l Single value
Sum of cation equivalents 3,87 mval/l Single value
Total hardness 1,8 mmol/l Single value
Trickling quotient 36,9 Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://sengenthal.de/wp-content/uploads/sites/3/2026/07/2026-01-14_Pruefbericht-Rathaus-Deining.pdf · 27.01.2026 · 14.01.26-10:15h · retrieved on 26/08/2026

Frequent questions about postcode 92369

How hard is the water in Postcode 92369?
ZV Wasserversorgung Sengenthal - Deining publishes a total hardness of 1,8 mmol/l for the supply zone Sengenthal (Probe: Rathaus Deining) — that corresponds to 10.1 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 27.01.2026, retrieved on 26/08/2026.
How much nitrate is in the drinking water in Postcode 92369?
ZV Wasserversorgung Sengenthal - Deining publishes a nitrate value of 2,2 mg/l for the supply zone Sengenthal (Probe: Rathaus Deining). The statutory parametric value is 50 mg/l; the measured value represents 4 % of the parametric value. Basis: 27.01.2026, retrieved on 26/08/2026.
Who supplies the drinking water in Postcode 92369?
ZV Wasserversorgung Sengenthal - Deining. The values shown here come from the supply zone Sengenthal (Probe: Rathaus Deining) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.