Skip to content
maunawai.info

Drinking water in 90518

One supply zone, water supplier: Stadtwerke Altdorf GmbH.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Wasserwerk Abgabe in das Versorgungsnetz Altdorf

Stadtwerke Altdorf GmbH

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
7.7 °dH
Hardness range soft
Key values Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
Sum of PFAS < n.n. µg/l
not detectable
0.1 µg/l Single value
Nitrate 1,0 mg/l NO3 50 mg/l Single value
Lead < 0,0020 mg/l Pb
below limit of quantification
10 µg/l Single value
Escherichia coli (E. coli) 0 KBE/10 0/100 ml Single value
Sulphate 21,3 mg/l SO4 250 mg/l Single value
Sodium 20,3 mg/l Na 200 mg/l Single value
Show all recorded parameters (56 — most recent value per parameter)

Microbiology (2)

Microbiology – Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/10 0/100 ml Single value
Intestinal enterococci 0 KBE/10 0/100 ml Single value

Chemical parameters (30)

Chemical parameters – Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0,50 µg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
Acrylamide < 0,025 µg/l
below limit of quantification
0.1 µg/l
< 25 % *
Single value
Antimony < 0,0010 mg/l Sb
below limit of quantification
5 µg/l Single value
Arsenic 0,0073 mg/l As 10 µg/l Single value
Benzene < 0,25 µg/l
below limit of quantification
1 µg/l
< 25 % *
Single value
Benzo(a)pyrene < 0,0025 µg/l
below limit of quantification
10 ng/l
< 25 % *
Single value
Bisphenol A < 0,01 µg/l
below limit of quantification
2.5 µg/l
< 0.4 % *
Single value
Boron < 0,027 mg/l B
below limit of quantification
1 mg/l Single value
Bromate < 0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Cadmium < 0,0005 mg/l Cd
below limit of quantification
3 µg/l Single value
Chlorate n.B. mg/l
not determined
70 µg/l Single value
Chlorite n.B. mg/l
not determined
0.2 mg/l Single value
Chromium < 0,0005 mg/l Cr
below limit of quantification
25 µg/l Single value
Copper < 0,0050 mg/l Cu
below limit of quantification
2 mg/l Single value
Cyanide < 0,005 mg/l CN
below limit of quantification
50 µg/l Single value
Epichlorohydrin 0,03 µg/l 0.1 µg/l
30 %
Single value
Fluoride 0,36 mg/l F 1.5 mg/l Single value
Lead < 0,0020 mg/l Pb
below limit of quantification
10 µg/l Single value
Mercury < 0,0002 mg/l Hg
below limit of quantification
1 µg/l Single value
Microcystin-LR n.B. mg/l
not determined
1 µg/l Single value
Nickel < 0,0050 mg/l Ni
below limit of quantification
20 µg/l Single value
Nitrate 1,0 mg/l NO3 50 mg/l Single value
Nitrite < 0,05 mg/l NO2
below limit of quantification
0.5 mg/l Single value
Pesticides — Total n.n. µg/l
not detectable
0.5 µg/l Single value
Selenium < 0,0010 mg/l Se
below limit of quantification
10 µg/l Single value
Tetrachloroethene < 0,5 µg/l
below limit of quantification
Single value
Trichloroethene < 0,5 µg/l
below limit of quantification
Single value
Trihalomethanes — Total n.n. mg/l
not detectable
50 µg/l Single value
Uranium < 0,0010 mg/l U
below limit of quantification
10 µg/l Single value
Vinyl chloride < 0,25 µg/l
below limit of quantification
0.5 µg/l
< 50 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

PFAS (1)

PFAS – Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
Sum of PFAS < n.n. µg/l
not detectable
0.1 µg/l Single value

Indicator parameters (18)

Indicator parameters – Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,005 mg/l Al
below limit of quantification
0.2 mg/l Single value
Ammonium < 0,05 mg/l NH4
below limit of quantification
0.5 mg/l Single value
Calcite dissolution capacity 0 mg/l 5 mg/l CaCO3 Single value
Chloride 15,3 mg/l Cl 250 mg/l Single value
Coliform bacteria 0 KBE/10 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Colour 0,05 m-1 0.5 m⁻¹ Single value
Iron < 0,010 mg/l Fe
below limit of quantification
0.2 mg/l Single value
Manganese < 0,005 mg/l Mn
below limit of quantification
50 µg/l Single value
Odour o.B. TON für den Verbraucher annehmbar Single value
pH 7,75 - 6,5–9,5 Single value
Sodium 20,3 mg/l Na 200 mg/l Single value
Sulphate 21,3 mg/l SO4 250 mg/l Single value
Taste o.B. - für den Verbraucher annehmbar Single value
Temperature 15,6 °C Single value
Total organic carbon (TOC) < 0,25 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity 0,07 NTU 1 NTU Single value

Further parameters (5)

Further parameters – Wasserwerk Abgabe in das Versorgungsnetz Altdorf
Parameter Value Parametric value Share of the parametric value Reference
Calcium 38,7 mg/l Ca Single value
Magnesium 10,2 mg/l Mg Single value
Oxygen 9,9 mg/l O2 Single value
Potassium 8,4 mg/l K Single value
Total hardness 7,7 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Frequent questions about postcode 90518

How hard is the water in Postcode 90518?
Stadtwerke Altdorf GmbH publishes a total hardness of 7.7 °dH for the supply zone Wasserwerk Abgabe in das Versorgungsnetz Altdorf (hardness range soft). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 11/07/2026.
Are PFAS detectable in the drinking water in Postcode 90518?
Stadtwerke Altdorf GmbH states for the supply zone Wasserwerk Abgabe in das Versorgungsnetz Altdorf that the sum PFAS-20 was not detectable (entry in the report: "< n.n."). This is not to be read as "PFAS-free": below the limit of quantification, the measurement cannot make any statement. The statutory parametric value is 0.1 µg/l; the measured value lies below it and cannot be specified more precisely below the limit of quantification. For the sum of the 20 individual substances, this parametric value has applied since 12/01/2026. Basis: Publication by the water supplier, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 90518?
Stadtwerke Altdorf GmbH. The values shown here come from the supply zone Wasserwerk Abgabe in das Versorgungsnetz Altdorf and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.