Skip to content
maunawai.info

Drinking water in 85386

One supply zone, water supplier: WZV Freising Süd.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)

WZV Freising Süd

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
14.3 °dH
Hardness range hart
Key values Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate <1,0 mg/l
below limit of quantification
50 mg/l
< 2 % *
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 41 mg/l 250 mg/l
16 %
Single value
Sodium 34,0 mg/l 200 mg/l
17 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (33 — most recent value per parameter)

Microbiology (1)

Microbiology – Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value

Chemical parameters (3)

Chemical parameters – Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)
Parameter Value Parametric value Share of the parametric value Reference
Arsenic 0,003 mg/l 10 µg/l
30 %
Single value
Nitrate <1,0 mg/l
below limit of quantification
50 mg/l
< 2 % *
Single value
Nitrite <0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (18)

Indicator parameters – Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,020 mg/l
below limit of quantification
0.2 mg/l
< 10 % *
Single value
Ammonium <0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value
Calcite dissolution capacity -15 mg/l 5 mg/l CaCO3 Single value
Chloride 17,6 mg/l 250 mg/l
7 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 1 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Colour farblos
Unit not stated in the document
0.5 m⁻¹ Single value
Conductivity (25 °C) 591 µS/cm 2,790 µS/cm Single value
Iron 0,085 mg/l 0.2 mg/l
43 %
Single value
Manganese 0,011 mg/l 50 µg/l
22 %
Single value
Odour ohne für den Verbraucher annehmbar Single value
pH 7,71 6,5–9,5 Single value
Sodium 34,0 mg/l 200 mg/l
17 %
Single value
Sulphate 41 mg/l 250 mg/l
16 %
Single value
Temperature 8,5 °C Single value
Total organic carbon (TOC) <0,5 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity klar
Unit not stated in the document
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (11)

Further parameters – Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 5,33 mmol/l Single value
Base capacity to pH 8.2 0,16 mmol/l Single value
Calcium 60,7 mg/l Single value
Carbonate hardness 14,3 °dH Single value
Dissolved organic carbon (DOC) 0,5 mg/l Single value
Free carbon dioxide 12 mg/l Single value
Hardness range (WRMG) hart Single value
Magnesium 25,1 mg/l Single value
Potassium 1,0 mg/l Single value
Silicate / silicic acid 14 mg/l Single value
Total hardness 2,55 mmol/l Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.wasserzv.de/_Resources/Persistent/e/d/6/0/ed60d89dbe4a02150c7e6eeedf36b823d68bae58/Analyse_Netz_Neufahrn.pdf · 17.11.2025 · Probenahme 01.10.2025 11:17 · retrieved on 11/07/2026

Frequent questions about postcode 85386

How hard is the water in Postcode 85386?
WZV Freising Süd publishes a total hardness of 2,55 mmol/l for the supply zone Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320) — that corresponds to 14.3 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 17.11.2025, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 85386?
WZV Freising Süd publishes a nitrate value of <1,0 mg/l for the supply zone Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320). The statutory parametric value is 50 mg/l; the measured value lies below it and cannot be specified more precisely below the limit of quantification. Basis: 17.11.2025, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 85386?
WZV Freising Süd. The values shown here come from the supply zone Aufbereitungsanlage Neufahrn, Reinw. Ausgang (OKZ: 1230763600320) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.