Drinking water in 84576
For this postcode Gemeinde Teising (Wasserversorgung) publishes several supply zones. Which of them serves an individual address is not published — below are the values of the zone with the most documented parameters, the remaining 11 underneath. The water supplier publishes 37 further local networks that cannot be clearly assigned to this postcode — they are listed on the water supplier page.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Gemeinde Teising, Saugbehälter Abgang Netz (Br. I, Teising)
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Sum of PFAS | 13 ng/l | 0.1 µg/l | 13 % | Single value |
Show all recorded parameters (25 — most recent value per parameter)
PFAS (25)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 4:2 Fluorotelomer sulfonic acid | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| 6:2 Fluorotelomer sulfonic acid | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| 8:2 Fluorotelomer sulfonic acid | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorobutane sulfonic acid (PFBS) | 1,3 ng/l | — | — | Single value |
| Perfluorobutanoic acid (PFBA) | < Bestimmungsgrenze ng/l not detectable | — | — | Single value |
| Perfluorodecane sulfonic acid (PFDS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorodecanoic acid (PFDA) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorododecane sulfonic acid (PFDoDS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorododecanoic acid (PFDoDA) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluoroheptane sulfonic acid (PFHpS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluoroheptanoic acid (PFHpA) | 1,3 ng/l | — | — | Single value |
| Perfluorohexane sulfonic acid (PFHxS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorohexanoic acid (PFHxA) | 1,7 ng/l | — | — | Single value |
| Perfluorononane sulfonic acid (PFNS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorononanoic acid (PFNA) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorooctanesulfonic acid (PFOS) | 0,32 ng/l | — | — | Single value |
| Perfluorooctanoic acid (PFOA) | 7,9 ng/l | — | — | Single value |
| Perfluoropentanesulfonic acid (PFPeS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluoropentanoic acid (PFPeA) | 0,42 ng/l | — | — | Single value |
| Perfluorotridecanesulfonic acid (PFTrDS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluorotridecanoic acid (PFTrDA) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluoroundecanesulfonic acid (PFUnDS) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Perfluoroundecanoic acid (PFUnDA) | < Nachweisgrenze ng/l not detectable | — | — | Single value |
| Sum of 4 PFAS | 8,2 ng/l | — | — | Single value |
| Sum of PFAS | 13 ng/l | 0.1 µg/l | 13 % | Single value |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Show 11 more supply zones in this postcode
Teising, Saugbehälter Abgang Netz, 06.03
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (13 — most recent value per parameter)
PFAS (13)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,22 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| HFPO-DA (GenX) | < 0,20 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorobutane sulfonic acid (PFBS) | 0,69 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorobutanesulfonamide (FBSA) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluoroheptanoic acid (PFHpA) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorohexane sulfonic acid (PFHxS) | < 0,20 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorohexanoic acid (PFHxA) | 1,6 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorononanoic acid (PFNA) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluorooctanoic acid (PFOA) | 7,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluoropentanesulfonic acid (PFPeS) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
| Perfluoropentanoic acid (PFPeA) | 0,31 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 06.03.2024 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 02.12
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,29 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorobutane sulfonic acid (PFBS) | 1,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorobutanesulfonamide (FBSA) | 0,38 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluoroheptanoic acid (PFHpA) | 1,7 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorohexanoic acid (PFHxA) | 2,0 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluorooctanoic acid (PFOA) | 8,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
| Perfluoropentanoic acid (PFPeA) | 0,48 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 02.12.2025 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 18.09
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (8 — most recent value per parameter)
PFAS (8)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | < 0,20 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluorobutane sulfonic acid (PFBS) | 1,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluorobutanoic acid (PFBA) | 2,3 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluoroheptanoic acid (PFHpA) | 1,3 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluorohexanoic acid (PFHxA) | 1,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluorooctanoic acid (PFOA) | 8,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
| Perfluoropentanoic acid (PFPeA) | 0,31 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 18.09.2024 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 09.03
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,26 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorobutane sulfonic acid (PFBS) | 1,3 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorobutanesulfonamide (FBSA) | 0,46 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluoroheptanoic acid (PFHpA) | 1,3 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorohexanoic acid (PFHxA) | 1,7 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluorooctanoic acid (PFOA) | 7,9 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
| Perfluoropentanoic acid (PFPeA) | 0,42 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 09.03.2026 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 19.03
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,28 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorobutane sulfonic acid (PFBS) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorobutanesulfonamide (FBSA) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluoroheptanoic acid (PFHpA) | 1,6 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorohexanoic acid (PFHxA) | 1,9 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluorooctanoic acid (PFOA) | 9,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
| Perfluoropentanoic acid (PFPeA) | 0,47 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 19.03.2025 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 22.09
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,21 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorobutane sulfonic acid (PFBS) | 1,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorobutanesulfonamide (FBSA) | 0,40 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluoroheptanoic acid (PFHpA) | 1,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorohexanoic acid (PFHxA) | 1,7 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluorooctanoic acid (PFOA) | 8,1 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
| Perfluoropentanoic acid (PFPeA) | 0,43 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 22.09.2025 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 25.06
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | < 0,20 ng/l below limit of quantification | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorobutane sulfonic acid (PFBS) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorobutanesulfonamide (FBSA) | 0,33 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorobutanoic acid (PFBA) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluoroheptanoic acid (PFHpA) | 1,3 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorohexanoic acid (PFHxA) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluorooctanoic acid (PFOA) | 7,6 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
| Perfluoropentanoic acid (PFPeA) | 0,46 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 25.06.2025 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 03.12
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (8 — most recent value per parameter)
PFAS (8)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 0,22 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluorobutane sulfonic acid (PFBS) | 1,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluoroheptanoic acid (PFHpA) | 1,4 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluorohexanoic acid (PFHxA) | 1,5 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluorooctanoic acid (PFOA) | 7,7 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
| Perfluoropentanoic acid (PFPeA) | 0,36 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 03.12.2024 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 04.06
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (9 — most recent value per parameter)
PFAS (9)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | < 0,20 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluorobutane sulfonic acid (PFBS) | 0,93 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluorobutanoic acid (PFBA) | < 1,5 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluoroheptanoic acid (PFHpA) | 1,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluorohexanoic acid (PFHxA) | 1,2 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,10 (NG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluorooctanoic acid (PFOA) | 7,6 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluoropentanesulfonic acid (PFPeS) | < 0,30 (BG) ng/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
| Perfluoropentanoic acid (PFPeA) | 0,29 ng/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 04.06.2024 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Br. I, Teising, 18.09
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (4 — most recent value per parameter)
PFAS (4)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| ADONA | 3,5 ng/l | — | — | Single value · Br. I, Teising, 18.09.2024 |
| Perfluoroheptanoic acid (PFHpA) | <0,004 µg/l below limit of quantification | — | — | Single value · Br. I, Teising, 18.09.2019 |
| Perfluorooctanesulfonic acid (PFOS) | < 1,0 (NG) ng/l not detectable | — | — | Single value · Br. I, Teising, 18.09.2024 |
| Perfluorooctanoic acid (PFOA) | 7,4 ng/l | — | — | Single value · Br. I, Teising, 18.09.2024 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Teising, Saugbehälter Abgang Netz, 12.12
Gemeinde Teising (Wasserversorgung)Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No core values are available for this zone yet.
Show all recorded parameters (3 — most recent value per parameter)
PFAS (3)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Perfluoroheptanoic acid (PFHpA) | <0,004 µg/l below limit of quantification | — | — | Single value · Teising, Saugbehälter Abgang Netz, 12.12.2019 |
| Perfluorooctanesulfonic acid (PFOS) | < 0,001 (NG) µg/l not detectable | — | — | Single value · Teising, Saugbehälter Abgang Netz, 12.12.2019 |
| Perfluorooctanoic acid (PFOA) | 0,008 ± 0,002 µg/l | — | — | Single value · Teising, Saugbehälter Abgang Netz, 12.12.2019 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Frequent questions about postcode 84576
- Are PFAS detectable in the drinking water in Postcode 84576?
- Gemeinde Teising (Wasserversorgung) publishes for the supply zone Gemeinde Teising, Saugbehälter Abgang Netz (Br. I, Teising) a sum value PFAS-20 of 13 ng/l (0.013 µg/l). The statutory parametric value is 0.1 µg/l; the measured value represents 13 % of the parametric value. For the sum of the 20 individual substances, this parametric value has applied since 12/01/2026. Basis: 27.05.2026, retrieved on 08/08/2026.
- Who supplies the drinking water in Postcode 84576?
- Gemeinde Teising (Wasserversorgung). The values shown here come from the supply zone Gemeinde Teising, Saugbehälter Abgang Netz (Br. I, Teising) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.