Drinking water in 69245
One supply zone, water supplier: Zweckverband GWV Unteres Elsenztal.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1)
Zweckverband GWV Unteres ElsenztalAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 06/07/2022. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Lead | <0,0005 mg/L below limit of quantification | 10 µg/l | < 5 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (17 — most recent value per parameter)
Chemical parameters (17)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Antimony | <0,0005 mg/L below limit of quantification | 5 µg/l | < 10 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Arsenic | 0,0005 mg/L | 10 µg/l | 5 % | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Benzo(a)pyrene | <0,0000020 mg/L below limit of quantification | 10 ng/l | < 20 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Benzo(b)fluoranthene | <0,000010 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Benzo(ghi)perylene | <0,000010 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Benzo(k)fluoranthene | <0,000010 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Bromodichloromethane | 0,001 mg/L | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Cadmium | <0,00005 mg/L below limit of quantification | 3 µg/l | < 2 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Copper | <0,010 mg/L below limit of quantification | 2 mg/l | < 0.5 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Dibromochloromethane | <0,001 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Indeno(1,2,3-cd)pyrene | <0,000010 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Lead | <0,0005 mg/L below limit of quantification | 10 µg/l | < 5 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Nickel | <0,0005 mg/L below limit of quantification | 20 µg/l | < 3 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Nitrite | <0,005 mg/L below limit of quantification | 0.5 mg/l | < 1 % * | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Tribromomethane (bromoform) | <0,001 mg/L below limit of quantification | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Trichloromethane (chloroform) | 0,0021 mg/L | — | — | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
| Trihalomethanes — Total | 0,0031 mg/L | 50 µg/l | 6 % | Single value · Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Frequent questions about postcode 69245
- Who supplies the drinking water in Postcode 69245?
- Zweckverband GWV Unteres Elsenztal. The values shown here come from the supply zone Wiesenbach, NZ, Bauhof, Heizraum, Ausgussbecken (55045/1) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.