Drinking water in 53902
For this postcode the responsible water supplier publishes several supply zones. Which of them serves an individual address is not published — below are the values of the zone with the most documented parameters, the remaining 1 underneath.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Wassergewinnungsanlagen Urfey [1], Hauser Benden [2], Düttling [3], Vlatten [4]/Gödersheimer Verband
Stadtwerke MechernichAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2019. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 in 100ml | 0/100 ml | — | Single value · Vlatten 2019 |
| Sulphate | 58,8 mg/l | 250 mg/l | 24 % | Single value · Vlatten 2019 |
| Sodium | 6,8 mg/l | 200 mg/l | 3 % | Single value · Vlatten 2019 |
Show all recorded parameters (19 — most recent value per parameter)
Microbiology (1)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 in 100ml | 0/100 ml | — | Single value · Vlatten 2019 |
Chemical parameters (1)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Chlorite | - mg/l not determined | 0.2 mg/l | — | Single value · Vlatten 2019 |
Indicator parameters (13)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | <0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Single value · Vlatten 2019 |
| Ammonium | <0,02 mg/l below limit of quantification | 0.5 mg/l | < 4 % * | Single value · Vlatten 2019 |
| Calcite dissolution capacity | - mg/l not determined | 5 mg/l CaCO3 | — | Single value · Vlatten 2019 |
| Chloride | 26,2 mg/l | 250 mg/l | 10 % | Single value · Vlatten 2019 |
| Colony count 22 °C | 0 in 1ml | ohne anormale Veränderung | — | Single value · Vlatten 2019 |
| Iron | <0,01 mg/l below limit of quantification | 0.2 mg/l | < 5 % * | Single value · Vlatten 2019 |
| Manganese | <0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Single value · Vlatten 2019 |
| Odour | ohne | für den Verbraucher annehmbar | — | Single value · Vlatten 2019 |
| Sodium | 6,8 mg/l | 200 mg/l | 3 % | Single value · Vlatten 2019 |
| Sulphate | 58,8 mg/l | 250 mg/l | 24 % | Single value · Vlatten 2019 |
| Temperature | 12,80 °C | — | — | Single value · Vlatten 2019 |
| Total organic carbon (TOC) | 2,5 mg/l | ohne anormale Veränderung | — | Single value · Vlatten 2019 |
| Turbidity | 0,078 NTU | 1 NTU | — | Single value · Vlatten 2019 |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (4)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Calcium | 75,10 mg/l | — | — | Single value · Vlatten 2019 |
| Carbonate hardness | - ° dH not determined | — | — | Single value · Vlatten 2019 |
| Magnesium | 40,0 mg/l | — | — | Single value · Vlatten 2019 |
| Total hardness | 20,00 ° dH | — | — | Single value · Vlatten 2019 |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Show 1 more supply zone in this postcode
Bad Münstereifel
Stadt Bad MünstereifelAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
No date is given for these values. The water supplier publishes the analysis without a sampling date and without a report date. When the water was examined is not apparent from the source — we do not add a date and we do not estimate one. What is stated is therefore only when we retrieved the document.
No core values are available for this zone yet.
Show all recorded parameters (2 — most recent value per parameter)
Indicator parameters (1)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| pH | 8,0 | 6,5–9,5 | — | Maximum · Bad Münstereifel |
Further parameters (1)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Total hardness | 5 °dH | — | — | Maximum · Bad Münstereifel |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Frequent questions about postcode 53902
- How hard is the water in Postcode 53902?
- Stadtwerke Mechernich publishes a total hardness of 20 °dH for the supply zone Wassergewinnungsanlagen Urfey [1], Hauser Benden [2], Düttling [3], Vlatten [4]/Gödersheimer Verband (hardness range hard). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 11/07/2026.
- Who supplies the drinking water in Postcode 53902?
- Stadtwerke Mechernich. The values shown here come from the supply zone Wassergewinnungsanlagen Urfey [1], Hauser Benden [2], Düttling [3], Vlatten [4]/Gödersheimer Verband and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.