Skip to content
maunawai.info

Drinking water in 52445

For this postcode the responsible water supplier publishes several supply zones. Which of them serves an individual address is not published — below are the values of the zone with the most documented parameters, the remaining 1 underneath.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)

Wasserwerk der Gemeinde Titz

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 02/04/2025. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
20.6 °dH
Hardness range hart
Key values Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate < 1,0 mg/l
below limit of quantification
50 mg/l
< 2 % *
Single value
Escherichia coli (E. coli) 0 MPN/100 ml 0/100 ml Single value
Sulphate 150 mg/l 250 mg/l
60 %
Single value
Sodium 19,9 mg/l 200 mg/l
10 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (69 — most recent value per parameter)

Microbiology (2)

Microbiology – Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 MPN/100 ml 0/100 ml Single value
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value

Chemical parameters (39)

Chemical parameters – Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0,0005 mg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
1,2-Dichloropropane < 0,1 µg/l
below limit of quantification
Single value
2,4-D < 0,00002 mg/l
below limit of quantification
Single value
Atrazine < 0,000025 mg/l
below limit of quantification
Single value
Bentazone < 0,00002 mg/l
below limit of quantification
Single value
Benzene < 0,00025 mg/l
below limit of quantification
1 µg/l
< 25 % *
Single value
Boron 0,02 mg/l 1 mg/l
2 %
Single value
Bromacil < 0,000025 mg/l
below limit of quantification
Single value
Bromate < 0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Carbofuran < 0,000025 mg/l
below limit of quantification
Single value
Chloridazon < 0,000025 mg/l
below limit of quantification
Single value
Chlorotoluron < 0,000025 mg/l
below limit of quantification
Single value
Chromium < 0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value
Clopyralid < 0,00005 mg/l
below limit of quantification
Single value
Cyanide < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Dicamba < 0,00005 mg/l
below limit of quantification
Single value
Dichlorprop < 0,00002 mg/l
below limit of quantification
Single value
Diuron < 0,000025 mg/l
below limit of quantification
Single value
Fluoride 0,35 mg/l 1.5 mg/l
23 %
Single value
Hexazinone < 0,000025 mg/l
below limit of quantification
Single value
Isoproturon < 0,000025 mg/l
below limit of quantification
Single value
MCPA < 0,00002 mg/l
below limit of quantification
Single value
Mecoprop < 0,00002 mg/l
below limit of quantification
Single value
Mercury < 0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value
Metazachlor < 0,000025 mg/l
below limit of quantification
Single value
Methabenzthiazuron < 0,000025 mg/l
below limit of quantification
Single value
Metobromuron < 0,000025 mg/l
below limit of quantification
Single value
Metolachlor < 0,000025 mg/l
below limit of quantification
Single value
Metoxuron < 0,000025 mg/l
below limit of quantification
Single value
Monuron < 0,000025 mg/l
below limit of quantification
Single value
Nitrate < 1,0 mg/l
below limit of quantification
50 mg/l
< 2 % *
Single value
Nitrite < 0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value
Propazine < 0,000025 mg/l
below limit of quantification
Single value
Selenium < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Simazine < 0,000025 mg/l
below limit of quantification
Single value
Terbuthylazine < 0,000025 mg/l
below limit of quantification
Single value
Tetrachloroethene < 0,0005 mg/l
below limit of quantification
Single value
Trichloroethene < 0,0005 mg/l
below limit of quantification
Single value
Uranium < 0,0001 mg/l
below limit of quantification
10 µg/l
< 1 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Metabolites (1)

Metabolites – Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
Desphenyl-chloridazon < 0,000025 mg/l
below limit of quantification
Single value

Indicator parameters (18)

Indicator parameters – Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,005 mg/l
below limit of quantification
0.2 mg/l
< 3 % *
Single value
Ammonium < 0,06 mg/l
below limit of quantification
0.5 mg/l
< 12 % *
Single value
Calcite dissolution capacity -6,9 mg/l 5 mg/l CaCO3 Single value
Chloride 32 mg/l 250 mg/l
13 %
Single value
Coliform bacteria 0 MPN/100 ml 0/100 ml Single value
Colony count 22 °C 0 KBE/1 ml ohne anormale Veränderung Single value
Colony count 36 °C 2 KBE/1 ml ohne anormale Veränderung Single value
Conductivity (25 °C) 778 µS/cm 2,790 µS/cm Single value
Iron 0,018 mg/l 0.2 mg/l
9 %
Single value
Manganese 0,009 mg/l 50 µg/l
18 %
Single value
Odour ohne für den Verbraucher annehmbar Single value
pH 7,5 6,5–9,5 Single value
Sodium 19,9 mg/l 200 mg/l
10 %
Single value
Sulphate 150 mg/l 250 mg/l
60 %
Single value
Taste ohne für den Verbraucher annehmbar Single value
Temperature 9,6 °C Single value
Total organic carbon (TOC) < 1,0 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity < 0,10 FNU
below limit of quantification
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (9)

Further parameters – Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 4,2 mmol/l Single value
Base capacity to pH 8.2 0,3 mmol/l Single value
Calcium 108 mg/l Single value
Carbonate hardness 2,11 mmol/l Single value
Hardness range (WRMG) hart Single value
Magnesium 24,1 mg/l Single value
Phosphate < 0,6 mg/l
below limit of quantification
Single value
Potassium 4,0 mg/l Single value
Total hardness 3,68 mmol/l Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://landgemeinde.de/daseinsfuersorge-soziales/wasserwerk/trinkwasseranalysen/Trinkwasseruntersuchung-Titz.pdf · Probenahme 17.03.2025, Prüfzeitraum 17.03.2025 - 02.04.2025 · retrieved on 13/07/2026
Show 1 more supply zone in this postcode

Wasserwerk Niederbusch

Verbandswasserwerk Gangelt GmbH

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
Hardness range mittel
Key values Wasserwerk Niederbusch
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 20 mg/l 50 mg/l
40 %
Single value · Wasserwerk Niederbusch
Lead < 0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value · Wasserwerk Niederbusch
Sulphate 81,0 mg/l 250 mg/l
32 %
Single value · Wasserwerk Niederbusch
Sodium 15,0 mg/l 200 mg/l
8 %
Single value · Wasserwerk Niederbusch

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (22 — most recent value per parameter)

Chemical parameters (9)

Chemical parameters – Wasserwerk Niederbusch
Parameter Value Parametric value Share of the parametric value Reference
Arsenic 0,001 mg/l 10 µg/l
10 %
Single value · Wasserwerk Niederbusch
Cadmium < 0,001 mg/l
below limit of quantification
3 µg/l
< 33 % *
Single value · Wasserwerk Niederbusch
Chromium < 0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value · Wasserwerk Niederbusch
Copper 0,0007 mg/l 2 mg/l
< 0.1 %
Single value · Wasserwerk Niederbusch
Fluoride < 0,1 mg/l
below limit of quantification
1.5 mg/l
< 7 % *
Single value · Wasserwerk Niederbusch
Lead < 0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value · Wasserwerk Niederbusch
Nickel 0,005 mg/l 20 µg/l
25 %
Single value · Wasserwerk Niederbusch
Nitrate 20 mg/l 50 mg/l
40 %
Single value · Wasserwerk Niederbusch
Nitrite < 0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value · Wasserwerk Niederbusch

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (9)

Indicator parameters – Wasserwerk Niederbusch
Parameter Value Parametric value Share of the parametric value Reference
Ammonium < 0,03 mg/l
below limit of quantification
0.5 mg/l
< 6 % *
Single value · Wasserwerk Niederbusch
Chloride 31,0 mg/l 250 mg/l
12 %
Single value · Wasserwerk Niederbusch
Colony count 22 °C 0 / 1 ml ohne anormale Veränderung Single value · Wasserwerk Niederbusch
Colony count 36 °C 0 / 1 ml ohne anormale Veränderung Single value · Wasserwerk Niederbusch
Iron < 0,010 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value · Wasserwerk Niederbusch
Manganese < 0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value · Wasserwerk Niederbusch
pH 7,74 6,5–9,5 Single value · Wasserwerk Niederbusch
Sodium 15,0 mg/l 200 mg/l
8 %
Single value · Wasserwerk Niederbusch
Sulphate 81,0 mg/l 250 mg/l
32 %
Single value · Wasserwerk Niederbusch

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Treatment substances (1)

Treatment substances – Wasserwerk Niederbusch
Parameter Value Parametric value Share of the parametric value Reference
Free chlorine nicht nachweisbar
not detectable
Single value · Wasserwerk Niederbusch

Further parameters (3)

Further parameters – Wasserwerk Niederbusch
Parameter Value Parametric value Share of the parametric value Reference
Calcium 77,0 mg/l Single value · Wasserwerk Niederbusch
Hardness range (WRMG) mittel Single value · Wasserwerk Niederbusch
Magnesium 8,0 mg/l Single value · Wasserwerk Niederbusch

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.verbandswasserwerk-gangelt.de/trinkwasser-qualitaet/ · Geilenkirchen, Mai 2025 · retrieved on 11/07/2026

Frequent questions about postcode 52445

How hard is the water in Postcode 52445?
Wasserwerk der Gemeinde Titz publishes a total hardness of 3,68 mmol/l for the supply zone Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis) — that corresponds to 20.6 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 13/07/2026.
How much nitrate is in the drinking water in Postcode 52445?
Wasserwerk der Gemeinde Titz publishes a nitrate value of < 1,0 mg/l for the supply zone Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis). The statutory parametric value is 50 mg/l; the measured value lies below it and cannot be specified more precisely below the limit of quantification. Basis: Publication by the water supplier, retrieved on 13/07/2026.
Who supplies the drinking water in Postcode 52445?
Wasserwerk der Gemeinde Titz. The values shown here come from the supply zone Wasserwerk der Gemeinde Titz, Entnahmestelle: Wasserwerk Ausgang (Teis) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.