Drinking water in 42853
One supply zone, water supplier: EWR GmbH.
How to read the share of the parametric value
Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.
Remscheid
EWR GmbHAssigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.
These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 31/12/2024. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Sum of PFAS | < 0,000001 mg/l below limit of quantification | — | — | Mean |
| Nitrate | 11 mg/l | 50 mg/l | 22 % | Mean |
| Lead | < 0,0006 mg/l below limit of quantification | 10 µg/l | < 6 % * | Mean |
| Escherichia coli (E. coli) | 0 Anzahl/100 ml | 0/100 ml | — | Mean |
| Sulphate | 14 mg/l | 250 mg/l | 6 % | Mean |
| Sodium | 5,3 mg/l | 200 mg/l | 3 % | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Show all recorded parameters (58 — most recent value per parameter)
Microbiology (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Escherichia coli (E. coli) | 0 Anzahl/100 ml | 0/100 ml | — | Mean |
| Intestinal enterococci | 0 Anzahl/100 ml | 0/100 ml | — | Mean |
Chemical parameters (30)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| 1,2-dichloroethane | < 0,0001 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Acrylamide | n.b. mg/l not determined | 0.1 µg/l | — | Mean |
| Antimony | < 0,0003 mg/l below limit of quantification | 5 µg/l | < 6 % * | Mean |
| Arsenic | < 0,0003 mg/l below limit of quantification | 10 µg/l | < 3 % * | Mean |
| Benzene | < 0,0001 mg/l below limit of quantification | 1 µg/l | < 10 % * | Mean |
| Benzo(a)pyrene | < 0,00001 mg/l below limit of quantification | 10 ng/l | < 100 % * | Mean |
| Bisphenol A | < 0,00003 mg/l below limit of quantification | 2.5 µg/l | < 1 % * | Mean |
| Boron | 0,014 mg/l | 1 mg/l | 1 % | Mean |
| Bromate | < 0,0005 mg/l below limit of quantification | 10 µg/l | < 5 % * | Mean |
| Cadmium | < 0,0001 mg/l below limit of quantification | 3 µg/l | < 3 % * | Mean |
| Chlorate | - mg/l not determined | 70 µg/l | — | Mean |
| Chlorite | - mg/l not determined | 0.2 mg/l | — | Mean |
| Chromium | < 0,0005 mg/l below limit of quantification | 25 µg/l | < 2 % * | Mean |
| Copper | < 0,0012 mg/l below limit of quantification | 2 mg/l | < < 0.1 % * | Mean |
| Cyanide | < 0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Fluoride | < 0,2 mg/l below limit of quantification | 1.5 mg/l | < 13 % * | Mean |
| Haloacetic acids (HAA) | n. b. mg/l not determined | — | — | Mean |
| Lead | < 0,0006 mg/l below limit of quantification | 10 µg/l | < 6 % * | Mean |
| Mercury | < 0,00005 below limit of quantification Unit not stated in the document | 1 µg/l | — | Mean |
| Microcystin-LR | < 0,00005 mg/l below limit of quantification | — | — | Mean |
| Nickel | 0,0004 mg/l | 20 µg/l | 2 % | Mean |
| Nitrate | 11 mg/l | 50 mg/l | 22 % | Mean |
| Nitrite | < 0,03 mg/l below limit of quantification | 0.5 mg/l | < 6 % * | Mean |
| Pesticides — Total | n.b. mg/l not determined | 0.5 µg/l | — | Mean |
| Polycyclic aromatic hydrocarbons | n.b. mg/l not determined | 0.1 µg/l | — | Mean |
| Selenium | < 0,0002 mg/l below limit of quantification | 10 µg/l | < 2 % * | Mean |
| Tetrachloroethene and Trichloroethene (sum) | < 0,0001 mg/l below limit of quantification | 10 µg/l | < 1 % * | Mean |
| Trihalomethanes — Total | n.b. mg/l not determined | 50 µg/l | — | Mean |
| Uranium | < 0,0001 mg/l below limit of quantification | 10 µg/l | < 1 % * | Mean |
| Vinyl chloride | n.b. mg/l not determined | 0.5 µg/l | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
PFAS (2)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Sum of 4 PFAS | < 0,000001 mg/l below limit of quantification | — | — | Mean |
| Sum of PFAS | < 0,000001 mg/l below limit of quantification | — | — | Mean |
Indicator parameters (17)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Aluminium | 0,007 mg/l | 0.2 mg/l | 3 % | Mean |
| Ammonium | < 0,05 mg/l below limit of quantification | 0.5 mg/l | < 10 % * | Mean |
| Calcite dissolution capacity | 1,74 mg/l CaCO3 | 5 mg/l CaCO3 | — | Mean |
| Chloride | 9 mg/l | 250 mg/l | 4 % | Mean |
| Clostridium perfringens (including spores) | 0 Anzahl/100 ml | 0/100 ml | — | Mean |
| Coliform bacteria | 0 Anzahl/100 ml | 0/100 ml | — | Mean |
| Colony count 22 °C | 0 Anzahl/ml | ohne anormale Veränderung | — | Mean |
| Colony count 36 °C | 0 Anzahl/ml | ohne anormale Veränderung | — | Mean |
| Colour | < 0,1 1 / m below limit of quantification | 0.5 m⁻¹ | — | Mean |
| Iron | < 0,02 mg/l below limit of quantification | 0.2 mg/l | < 10 % * | Mean |
| Manganese | < 0,005 mg/l below limit of quantification | 50 µg/l | < 10 % * | Mean |
| Odour | ohne | für den Verbraucher annehmbar | — | Single value |
| pH | 8,0 | 6,5–9,5 | — | Mean |
| Sodium | 5,3 mg/l | 200 mg/l | 3 % | Mean |
| Sulphate | 14 mg/l | 250 mg/l | 6 % | Mean |
| Taste | ohne | für den Verbraucher annehmbar | — | Single value |
| Turbidity | 0.07 NTU | 1 NTU | — | Mean |
* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.
Further parameters (7)
| Parameter | Value | Parametric value | Share of the parametric value | Reference |
|---|---|---|---|---|
| Acid capacity to pH 4.3 | 1,48 mmol/l | — | — | Mean |
| Calcium | 33 mg/l | — | — | Mean |
| Carbonate hardness | 4,1 ° dH (als CaO) | — | — | Mean |
| Hardness range (WRMG) | weich | — | — | Single value |
| Magnesium | 3,3 mg/l | — | — | Mean |
| Potassium | 1,6 mg/l | — | — | Mean |
| Total hardness | 5,3 ° dH (als CaO) | — | — | Mean |
Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.
Frequent questions about postcode 42853
- How hard is the water in Postcode 42853?
- EWR GmbH publishes a total hardness of 5.3 °dH for the supply zone Remscheid (hardness range weich). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: Publication by the water supplier, retrieved on 25/07/2026.
- How much nitrate is in the drinking water in Postcode 42853?
- EWR GmbH publishes a nitrate value of 11 mg/l for the supply zone Remscheid. The statutory parametric value is 50 mg/l; the measured value represents 22 % of the parametric value. Basis: Publication by the water supplier, retrieved on 25/07/2026.
- Who supplies the drinking water in Postcode 42853?
- EWR GmbH. The values shown here come from the supply zone Remscheid and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.
General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.