Skip to content
maunawai.info

Drinking water in 33818

For this postcode Gemeinde Leopoldshöhe (Wasserwerk Asemissen) publishes several supply zones. Which of them serves an individual address is not published — below are the values of the zone with the most documented parameters, the remaining 1 underneath.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe

Gemeinde Leopoldshöhe (Wasserwerk Asemissen)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 01/04/2025. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

Water hardness
25.2 °dH
Hardness range hart
Key values Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 22 mg/l 50 mg/l
44 %
Single value
Lead <0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Sulphate 116 mg/l 250 mg/l
46 %
Single value
Sodium 10,4 mg/l 200 mg/l
5 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (56 — most recent value per parameter)

Chemical parameters (35)

Chemical parameters – Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane <0,5 µg/l
below limit of quantification
3 µg/l
< 17 % *
Single value
Antimony <0,0010 mg/l
below limit of quantification
5 µg/l
< 20 % *
Single value
Arsenic <0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Benzene <0,3 µg/l
below limit of quantification
1 µg/l
< 30 % *
Single value
Benzo(a)pyrene <0,000002 mg/l
below limit of quantification
10 ng/l
< 20 % *
Single value
Benzo(b)fluoranthene <0,000002 mg/l
below limit of quantification
Single value
Benzo(ghi)perylene <0,000002 mg/l
below limit of quantification
Single value
Benzo(k)fluoranthene <0,000002 mg/l
below limit of quantification
Single value
Bisphenol A <0,005 µg/l
below limit of quantification
2.5 µg/l
< 0.2 % *
Single value
Boron 0,0340 mg/l 1 mg/l
3 %
Single value
Bromate <0,0030 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Bromodichloromethane <0,5 µg/l
below limit of quantification
Single value
Cadmium <0,00010 mg/l
below limit of quantification
3 µg/l
< 3 % *
Single value
Chromium 0,00021 mg/l 25 µg/l
0.8 %
Single value
Copper <0,0100 mg/l
below limit of quantification
2 mg/l
< 0.5 % *
Single value
Cyanide <0,005 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Dibromochloromethane <0,5 µg/l
below limit of quantification
Single value
Fluoranthene <0,000005 mg/l
below limit of quantification
Single value
Fluoride <0,1 mg/l
below limit of quantification
1.5 mg/l
< 7 % *
Single value
Indeno(1,2,3-cd)pyrene <0,002 µg/l
below limit of quantification
Single value
Lead <0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Mercury <0,0001 mg/l
below limit of quantification
1 µg/l
< 10 % *
Single value
Nickel <0,0010 mg/l
below limit of quantification
20 µg/l
< 5 % *
Single value
Nitrate 22 mg/l 50 mg/l
44 %
Single value
Nitrite <0,005 mg/l
below limit of quantification
0.5 mg/l
< 1 % *
Single value
Polycyclic aromatic hydrocarbons n.b. mg/l
not determined
0.1 µg/l Single value
Selenium <0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Tetrachloroethene <0,5 µg/l
below limit of quantification
Single value
Tetrachloroethene and Trichloroethene (sum) <0,5 µg/l
below limit of quantification
10 µg/l
< 5 % *
Single value
Tribromomethane (bromoform) <1,00 µg/l
below limit of quantification
Single value
Trichloroethene <0,5 µg/l
below limit of quantification
Single value
Trichloromethane (chloroform) <0,5 µg/l
below limit of quantification
Single value
Trihalomethanes — Total <0,0005 mg/l
below limit of quantification
50 µg/l
< 1 % *
Single value
Uranium 0,00046 mg/l 10 µg/l
5 %
Single value
Vinyl chloride <0,5 µg/l
below limit of quantification
0.5 µg/l
< 100 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (15)

Indicator parameters – Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,0050 mg/l
below limit of quantification
0.2 mg/l
< 3 % *
Single value
Ammonium <0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Calcite dissolution capacity -17,5 mg/l 5 mg/l CaCO3 Single value
Chloride 20 mg/l 250 mg/l
8 %
Single value
Colour <0,1 1/m
below limit of quantification
0.5 m⁻¹ Single value
Conductivity (25 °C) 877 µS/cm 2,790 µS/cm Single value
Iron <0,010 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese <0,0050 mg/l
below limit of quantification
50 µg/l
< 10 % *
Single value
Oxidisability <0,50 mg/l
below limit of quantification
5 mg/l O2 Single value
pH 7,17 6,5–9,5 Single value
Sodium 10,4 mg/l 200 mg/l
5 %
Single value
Sulphate 116 mg/l 250 mg/l
46 %
Single value
Temperature 9,6 °C Single value
Total organic carbon (TOC) <0,5 mg/l
below limit of quantification
ohne anormale Veränderung Single value
Turbidity <0,05 NTU
below limit of quantification
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (6)

Further parameters – Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 6,44 mmol/l Single value
Calcium 143 mg/l Single value
Hardness range (WRMG) hart Single value
Magnesium 22,4 mg/l Single value
Potassium 1,53 mg/l Single value
Total hardness 25,2 °dH Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.leopoldshoehe.de/bauen-wohnen/kanal-wasser/trinkwasseranalyse-2025.pdf · 14.05.2025 · 01.04.2025 · retrieved on 11/07/2026
Show 1 more supply zone in this postcode

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

These values are more than a year old. The most recent analysis the water supplier has published for this zone dates from 01/04/2025. We have no newer values — which is why we show the latest available ones rather than none at all. They say nothing about how the water has changed since then.

No core values are available for this zone yet.

Show all recorded parameters (1 — most recent value per parameter)

Indicator parameters (1)

Indicator parameters – OS
Parameter Value Parametric value Share of the parametric value Reference
Total organic carbon (TOC) <0,5 mg/l
below limit of quantification
ohne anormale Veränderung Single value · OS

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.leopoldshoehe.de/bauen-wohnen/kanal-wasser/trinkwasseranalyse-2025.pdf · 14.05.2025 · 01.04.2025 · retrieved on 11/07/2026

Frequent questions about postcode 33818

How hard is the water in Postcode 33818?
Gemeinde Leopoldshöhe (Wasserwerk Asemissen) publishes a total hardness of 25.2 °dH for the supply zone Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe (hardness range hart). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 14.05.2025, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 33818?
Gemeinde Leopoldshöhe (Wasserwerk Asemissen) publishes a nitrate value of 22 mg/l for the supply zone Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe. The statutory parametric value is 50 mg/l; the measured value represents 44 % of the parametric value. Basis: 14.05.2025, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 33818?
Gemeinde Leopoldshöhe (Wasserwerk Asemissen). The values shown here come from the supply zone Wasserwerk Asemissen, Entnahmestelle: Abgangsleitung - Schieberkammer, 33818 Leopoldshöhe and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.