Skip to content
maunawai.info

Drinking water in 33775

One supply zone, water supplier: Stadtwerke Versmold.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe

Stadtwerke Versmold

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 13 mg/l 50 mg/l
26 %
Single value
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Single value
Sulphate 74 mg/l 250 mg/l
30 %
Single value
Sodium 14,9 mg/l 200 mg/l
7 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (35 — most recent value per parameter)

Microbiology (2)

Microbiology – Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 in 100 ml 0/100 ml Single value
Intestinal enterococci 0 in 100 ml 0/100 ml Single value

Chemical parameters (13)

Chemical parameters – Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe
Parameter Value Parametric value Share of the parametric value Reference
Antimony < 0,0005 mg/l
below limit of quantification
5 µg/l
< 10 % *
Single value
Arsenic < 0,002 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Benzo(a)pyrene < 0,000003 mg/l
below limit of quantification
10 ng/l
< 30 % *
Single value
Bisphenol A < 0,00005 mg/l
below limit of quantification
2.5 µg/l
< 2 % *
Single value
Cadmium < 0,001 mg/l
below limit of quantification
3 µg/l
< 33 % *
Single value
Copper 0,01 mg/l 2 mg/l
0.5 %
Single value
Epichlorohydrin < 0,00003 mg/l
below limit of quantification
0.1 µg/l
< 30 % *
Single value
Lead < 0,001 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Nickel 0,007 mg/l 20 µg/l
35 %
Single value
Nitrate 13 mg/l 50 mg/l
26 %
Single value
Nitrite < 0,02 mg/l
below limit of quantification
0.5 mg/l
< 4 % *
Single value
Trihalomethanes — Total < 0,004 mg/l
below limit of quantification
50 µg/l
< 8 % *
Single value
Vinyl chloride < 0,0002 mg/l
below limit of quantification
0.5 µg/l
< 40 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (15)

Indicator parameters – Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe
Parameter Value Parametric value Share of the parametric value Reference
Aluminium 0,01 mg/l 0.2 mg/l
5 %
Single value
Ammonium < 0,05 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Chloride 26 mg/l 250 mg/l
10 %
Single value
Coliform bacteria 0 in 100 ml 0/100 ml Single value
Colony count 22 °C 0 in 1 ml ohne anormale Veränderung Single value
Colony count 36 °C 0 in 1 ml ohne anormale Veränderung Single value
Colour 0,3 1/m 0.5 m⁻¹ Single value
Iron 0,02 mg/l 0.2 mg/l
10 %
Single value
Manganese < 0,01 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value
Odour Ohne für den Verbraucher annehmbar Single value
pH 7,97 6,5–9,5 Single value
Sodium 14,9 mg/l 200 mg/l
7 %
Single value
Sulphate 74 mg/l 250 mg/l
30 %
Single value
Total organic carbon (TOC) 3,5 mg/l ohne anormale Veränderung Single value
Turbidity 0,43 FNU 1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (5)

Further parameters – Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 3,32 mmol/l Single value
Calcium 93,8 mg/l Single value
Carbonate hardness 9,3 °dH Single value
Magnesium 3,6 mg/l Single value
Potassium 4,8 mg/l Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Frequent questions about postcode 33775

How much nitrate is in the drinking water in Postcode 33775?
Stadtwerke Versmold publishes a nitrate value of 13 mg/l for the supply zone Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe. The statutory parametric value is 50 mg/l; the measured value represents 26 % of the parametric value. Basis: Publication by the water supplier, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 33775?
Stadtwerke Versmold. The values shown here come from the supply zone Westbarthausener Str. 5/ Versmold, Bockhorst Netzprobe and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.