One supply zone, water supplier: Stadtwerke Emden GmbH (Emder Wasser).

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser

Stadtwerke Emden GmbH (Emder Wasser)

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
9.9 °dH
Hardness range medium
Key values Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 2,40 mg/l 50 mg/l
5 %
Single value
Lead < 0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Escherichia coli (E. coli) 0
Unit not stated in the document
0/100 ml Single value
Sulphate < 10,00 mg/l
below limit of quantification
250 mg/l
< 4 % *
Single value
Sodium 23,00 mg/l 200 mg/l
12 %
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Show all recorded parameters (39 — most recent value per parameter)

Microbiology (2)

Microbiology – Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0
Unit not stated in the document
0/100 ml Single value
Intestinal enterococci 0
Unit not stated in the document
0/100 ml Single value

Chemical parameters (19)

Chemical parameters – Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser
Parameter Value Parametric value Share of the parametric value Reference
1,2-dichloroethane < 0,000900 mg/l
below limit of quantification
3 µg/l
< 30 % *
Single value
Antimony < 0.0015 mg/l
below limit of quantification
5 µg/l
< 30 % *
Single value
Arsenic < 0,0010 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value
Benzo(a)pyrene < 0,000003 mg/l
below limit of quantification
10 ng/l
< 30 % *
Single value
Boron < 0,0500 mg/l
below limit of quantification
1 mg/l
< 5 % *
Single value
Bromate < 0,003 mg/l
below limit of quantification
10 µg/l
< 30 % *
Single value
Cadmium < 0,0002 mg/l
below limit of quantification
3 µg/l
< 7 % *
Single value
Chromium < 0,0005 mg/l
below limit of quantification
25 µg/l
< 2 % *
Single value
Cyanide < 0,004 mg/l
below limit of quantification
50 µg/l
< 8 % *
Single value
Fluoride < 0,150 mg/l
below limit of quantification
1.5 mg/l
< 10 % *
Single value
Glyphosate < 0,000030 mg/l
below limit of quantification
Single value
Lead < 0,0025 mg/l
below limit of quantification
10 µg/l
< 25 % *
Single value
Nickel < 0,005 mg/l
below limit of quantification
20 µg/l
< 25 % *
Single value
Nitrate 2,40 mg/l 50 mg/l
5 %
Single value
Nitrite < 0,050 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Polycyclic aromatic hydrocarbons < 0,000028 mg/l
below limit of quantification
0.1 µg/l
< 28 % *
Single value
Selenium < 0,0020 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Tetrachloroethene and Trichloroethene (sum) < 0,002000 mg/l
below limit of quantification
10 µg/l
< 20 % *
Single value
Uranium < 0,001000 mg/l
below limit of quantification
10 µg/l
< 10 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (13)

Indicator parameters – Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser
Parameter Value Parametric value Share of the parametric value Reference
Aluminium < 0,0100 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Ammonium < 0,050 mg/l
below limit of quantification
0.5 mg/l
< 10 % *
Single value
Chloride 61,00 mg/l 250 mg/l
24 %
Single value
Coliform bacteria 0
Unit not stated in the document
0/100 ml Single value
Colony count 22 °C 4 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 1 KBE/ml ohne anormale Veränderung Single value
Conductivity (25 °C) 534,0 µS/cm 2,790 µS/cm Single value
Iron <0,010 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Manganese < 0,010 mg/l
below limit of quantification
50 µg/l
< 20 % *
Single value
Oxidisability 3,20 mg/l 5 mg/l O2 Single value
Sodium 23,00 mg/l 200 mg/l
12 %
Single value
Sulphate < 10,00 mg/l
below limit of quantification
250 mg/l
< 4 % *
Single value
Total organic carbon (TOC) 3,600 mg/l ohne anormale Veränderung Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (5)

Further parameters – Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser
Parameter Value Parametric value Share of the parametric value Reference
Calcium 60,00 mg/l Single value
Magnesium 6,7 mg/l Single value
Potassium < 2,5 mg/l
below limit of quantification
Single value
Total hardness 9,91 °dH Single value
Zinc < 0,050 mg/l
below limit of quantification
Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://stadtwerke-emden.de/fileadmin/Medien/Dokumente/Downloads/Produkte/Wasser/Trinkwasseranalyse.pdf · März 2026 · 11.03.2026 / 10:00 Uhr (Probenahme) · retrieved on 11/07/2026

Frequent questions about postcode 26723

How hard is the water in Postcode 26723?
Stadtwerke Emden GmbH (Emder Wasser) publishes a total hardness of 9.9 °dH for the supply zone Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser (hardness range medium). The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: März 2026, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 26723?
Stadtwerke Emden GmbH (Emder Wasser) publishes a nitrate value of 2,40 mg/l for the supply zone Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser. The statutory parametric value is 50 mg/l; the measured value represents 5 % of the parametric value. Basis: März 2026, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 26723?
Stadtwerke Emden GmbH (Emder Wasser). The values shown here come from the supply zone Wasserwerk Tergast – Stadtgebiet Emden (ausgenommen Wybelsum und Twixlum), Reinwasser and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.