One supply zone, water supplier: Stadtwerke Husum Netz GmbH.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)

Stadtwerke Husum Netz GmbH

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
12.6 °dH
Hardness range mittel
Key values Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 0,827 mg/l 50 mg/l
2 %
Single value
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value
Sulphate 42 mg/l 250 mg/l
17 %
Single value
Sodium 25,9 mg/l 200 mg/l
13 %
Single value
Show all recorded parameters (31 — most recent value per parameter)

Microbiology (1)

Microbiology – Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100ml 0/100 ml Single value

Chemical parameters (2)

Chemical parameters – Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 0,827 mg/l 50 mg/l
2 %
Single value
Nitrite <0,005 (+) mg/l
below limit of quantification
0.5 mg/l
< 1 % *
Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (18)

Indicator parameters – Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)
Parameter Value Parametric value Share of the parametric value Reference
Aluminium <0,01 mg/l
below limit of quantification
0.2 mg/l
< 5 % *
Single value
Ammonium <0,005 (NWG) mg/l
not detectable
0.5 mg/l Single value
Calcite dissolution capacity -1 mg/l 5 mg/l CaCO3 Single value
Chloride 60 mg/l 250 mg/l
24 %
Single value
Coliform bacteria 0 KBE/100ml 0/100 ml Single value
Colony count 22 °C 0 KBE/ml ohne anormale Veränderung Single value
Colony count 36 °C 0 KBE/ml ohne anormale Veränderung Single value
Colour farblos
Unit not stated in the document
0.5 m⁻¹ Single value
Conductivity (25 °C) 577 µS/cm 2,790 µS/cm Single value
Iron <0,003 (NWG) mg/l
not detectable
0.2 mg/l Single value
Manganese <0,002 (NWG) mg/l
not detectable
50 µg/l Single value
Odour ohne für den Verbraucher annehmbar Single value
pH 7,86 6,5–9,5 Single value
Sodium 25,9 mg/l 200 mg/l
13 %
Single value
Sulphate 42 mg/l 250 mg/l
17 %
Single value
Temperature 19,2 °C Single value
Total organic carbon (TOC) 1,2 mg/l ohne anormale Veränderung Single value
Turbidity keine
Unit not stated in the document
1 NTU Single value

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (10)

Further parameters – Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2)
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 3,29 mmol/l Single value
Base capacity to pH 8.2 0,21 mmol/l Single value
Calcium 83,1 mg/l Single value
Carbonate hardness 9,1 °dH Single value
Free carbon dioxide 10 mg/l Single value
Hardness range (WRMG) mittel Single value
Hydrogen carbonate 197,7 mg/l Single value
Magnesium 4,16 mg/l Single value
Potassium 1,36 mg/l Single value
Total hardness 2,24 mmol/l Single value

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.husumnetz.de/wp-content/uploads/2026/06/Wasseranalyse-Stadtwerke-Husum-Netz.pdf · 10.02.2026 · Probenahme 29.01.2026 07:25 (Eigenkontrolle Januar) · retrieved on 11/07/2026

Frequent questions about postcode 25813

How hard is the water in Postcode 25813?
Stadtwerke Husum Netz GmbH publishes a total hardness of 2,24 mmol/l for the supply zone Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2) — that corresponds to 12.6 °dH. The hardness range is a classification under the German Detergents and Cleaning Products Act (soft below 8,4 °dH, medium 8,4 to 14 °dH, hard above that) and not a quality verdict — it indicates how much calcium and magnesium is dissolved in the water. Basis: 10.02.2026, retrieved on 11/07/2026.
How much nitrate is in the drinking water in Postcode 25813?
Stadtwerke Husum Netz GmbH publishes a nitrate value of 0,827 mg/l for the supply zone Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2). The statutory parametric value is 50 mg/l; the measured value represents 2 % of the parametric value. Basis: 10.02.2026, retrieved on 11/07/2026.
Who supplies the drinking water in Postcode 25813?
Stadtwerke Husum Netz GmbH. The values shown here come from the supply zone Wasserwerk Mildstedt, Pumpenhaus Werkausgang (Reinwasser, Husum 2) and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.