Skip to content
maunawai.info

Drinking water in 8793 (Austria)

For this postcode Marktgemeinde Kammern im Liesingtal publishes several supply zones. Which of them serves an individual address is not published — below are the values of the zone with the most documented parameters, the remaining 6 underneath.

The values come from the Austrian drinking water database, to which water suppliers report voluntarily. In each case the highest value of the published range is given.

How to read the share of the parametric value

12 % Share of the parametric value. The proportion of the permitted maximum that the measured value uses — here 12 %, so just over an eighth.
< 10 % * Below the limit of quantification. The substance was not detectable. The mark shows where the detection limit lies relative to the parametric value — the actual share of the parametric value is below that.

Several samples per year: for chemical parameters the mean value is given, for microbiological ones the highest measured value. There the parametric value is zero — a single finding would disappear in the average, and it is precisely that finding which is the information. Which reference applies is stated in the last column of the table.

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
7 °dH
Key values P2 Hochbehälter Seiz
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,1 mg/l 50 mg/l
10 %
Single value · P2 Hochbehälter Seiz
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P2 Hochbehälter Seiz
Sulphate 5,7 mg/l 250 mg/l
2 %
Single value · P2 Hochbehälter Seiz
Sodium 0,5 mg/l 200 mg/l
0.3 %
Single value · P2 Hochbehälter Seiz
Show all recorded parameters (22 — most recent value per parameter)

Microbiology (2)

Microbiology – P2 Hochbehälter Seiz
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P2 Hochbehälter Seiz
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P2 Hochbehälter Seiz

Chemical parameters (2)

Chemical parameters – P2 Hochbehälter Seiz
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,1 mg/l 50 mg/l
10 %
Single value · P2 Hochbehälter Seiz
Nitrite < 0,005 mg/l
below limit of quantification
0.1 mg/l
< 5 % *
Single value · P2 Hochbehälter Seiz

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (11)

Indicator parameters – P2 Hochbehälter Seiz
Parameter Value Parametric value Share of the parametric value Reference
Ammonium < 0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value · P2 Hochbehälter Seiz
Chloride < 1,0 mg/l
below limit of quantification
200 mg/l
< 0.5 % *
Single value · P2 Hochbehälter Seiz
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P2 Hochbehälter Seiz
Colony count 22 °C 1 KBE/ml 100 1/ml Single value · P2 Hochbehälter Seiz
Colony count 36 °C 1 KBE/ml 20 1/ml Single value · P2 Hochbehälter Seiz
Conductivity (25 °C) 218 µS/cm 2,500 µS/cm Single value · P2 Hochbehälter Seiz
Iron < 0,0005 mg/l
below limit of quantification
0.2 mg/l
< 0.3 % *
Single value · P2 Hochbehälter Seiz
Manganese < 0,0001 mg/l
below limit of quantification
50 µg/l
< 0.2 % *
Single value · P2 Hochbehälter Seiz
Sodium 0,5 mg/l 200 mg/l
0.3 %
Single value · P2 Hochbehälter Seiz
Sulphate 5,7 mg/l 250 mg/l
2 %
Single value · P2 Hochbehälter Seiz
Total organic carbon (TOC) < 0,3 mg/l
below limit of quantification
Single value · P2 Hochbehälter Seiz

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – P2 Hochbehälter Seiz
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,42 mmol/l Single value · P2 Hochbehälter Seiz
Calcium 45,5 mg/l 400 mg/l
11 %
Single value · P2 Hochbehälter Seiz
Carbonate hardness 6,6 °dH Single value · P2 Hochbehälter Seiz
Hydrogen carbonate 145 mg/l Single value · P2 Hochbehälter Seiz
Magnesium 2,8 mg/l 150 mg/l
2 %
Single value · P2 Hochbehälter Seiz
Potassium 0,2 mg/l 50 mg/l
0.4 %
Single value · P2 Hochbehälter Seiz
Total hardness 1,25 mmol/l Single value · P2 Hochbehälter Seiz

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026
Show 6 more supply zones in this postcode

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Water hardness
6.9 °dH
Key values P5 Kindergarten Seiz
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,1 mg/l 50 mg/l
10 %
Single value · P5 Kindergarten Seiz
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P5 Kindergarten Seiz
Sulphate 5,5 mg/l 250 mg/l
2 %
Single value · P5 Kindergarten Seiz
Sodium 0,5 mg/l 200 mg/l
0.3 %
Single value · P5 Kindergarten Seiz
Show all recorded parameters (22 — most recent value per parameter)

Microbiology (2)

Microbiology – P5 Kindergarten Seiz
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P5 Kindergarten Seiz
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P5 Kindergarten Seiz

Chemical parameters (2)

Chemical parameters – P5 Kindergarten Seiz
Parameter Value Parametric value Share of the parametric value Reference
Nitrate 5,1 mg/l 50 mg/l
10 %
Single value · P5 Kindergarten Seiz
Nitrite < 0,005 mg/l
below limit of quantification
0.1 mg/l
< 5 % *
Single value · P5 Kindergarten Seiz

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Indicator parameters (11)

Indicator parameters – P5 Kindergarten Seiz
Parameter Value Parametric value Share of the parametric value Reference
Ammonium < 0,01 mg/l
below limit of quantification
0.5 mg/l
< 2 % *
Single value · P5 Kindergarten Seiz
Chloride < 1,0 mg/l
below limit of quantification
200 mg/l
< 0.5 % *
Single value · P5 Kindergarten Seiz
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P5 Kindergarten Seiz
Colony count 22 °C 3 KBE/ml 100 1/ml Single value · P5 Kindergarten Seiz
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · P5 Kindergarten Seiz
Conductivity (25 °C) 219 µS/cm 2,500 µS/cm Single value · P5 Kindergarten Seiz
Iron 0,0018 mg/l 0.2 mg/l
0.9 %
Single value · P5 Kindergarten Seiz
Manganese < 0,0001 mg/l
below limit of quantification
50 µg/l
< 0.2 % *
Single value · P5 Kindergarten Seiz
Sodium 0,5 mg/l 200 mg/l
0.3 %
Single value · P5 Kindergarten Seiz
Sulphate 5,5 mg/l 250 mg/l
2 %
Single value · P5 Kindergarten Seiz
Total organic carbon (TOC) 0,3 mg/l Single value · P5 Kindergarten Seiz

* Value below the limit of quantification: the actual share of the parametric value is not known; it lies somewhere below the stated upper bound. The marker shows where the limit of quantification of the measurement lies relative to the parametric value.

Further parameters (7)

Further parameters – P5 Kindergarten Seiz
Parameter Value Parametric value Share of the parametric value Reference
Acid capacity to pH 4.3 2,44 mmol/l Single value · P5 Kindergarten Seiz
Calcium 44,7 mg/l 400 mg/l
11 %
Single value · P5 Kindergarten Seiz
Carbonate hardness 6,7 °dH Single value · P5 Kindergarten Seiz
Hydrogen carbonate 146 mg/l Single value · P5 Kindergarten Seiz
Magnesium 2,8 mg/l 150 mg/l
2 %
Single value · P5 Kindergarten Seiz
Potassium 0,2 mg/l 50 mg/l
0.4 %
Single value · P5 Kindergarten Seiz
Total hardness 1,23 mmol/l Single value · P5 Kindergarten Seiz

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

P1 Stollenquelle Dirnsdorf

Marktgemeinde Kammern im Liesingtal

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values P1 Stollenquelle Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P1 Stollenquelle Dirnsdorf
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – P1 Stollenquelle Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P1 Stollenquelle Dirnsdorf
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P1 Stollenquelle Dirnsdorf

Indicator parameters (4)

Indicator parameters – P1 Stollenquelle Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P1 Stollenquelle Dirnsdorf
Colony count 22 °C 0 KBE/ml 100 1/ml Single value · P1 Stollenquelle Dirnsdorf
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · P1 Stollenquelle Dirnsdorf
Conductivity (25 °C) 211 µS/cm 2,500 µS/cm Single value · P1 Stollenquelle Dirnsdorf

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values P4 Volksschule Kammern
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P4 Volksschule Kammern
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – P4 Volksschule Kammern
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P4 Volksschule Kammern
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P4 Volksschule Kammern

Indicator parameters (4)

Indicator parameters – P4 Volksschule Kammern
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P4 Volksschule Kammern
Colony count 22 °C 1 KBE/ml 100 1/ml Single value · P4 Volksschule Kammern
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · P4 Volksschule Kammern
Conductivity (25 °C) 215 µS/cm 2,500 µS/cm Single value · P4 Volksschule Kammern

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values P6 Putz Reinhold
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P6 Putz Reinhold
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – P6 Putz Reinhold
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P6 Putz Reinhold
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P6 Putz Reinhold

Indicator parameters (4)

Indicator parameters – P6 Putz Reinhold
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P6 Putz Reinhold
Colony count 22 °C 4 KBE/ml 100 1/ml Single value · P6 Putz Reinhold
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · P6 Putz Reinhold
Conductivity (25 °C) 218 µS/cm 2,500 µS/cm Single value · P6 Putz Reinhold

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values P7 Obergruber Helmut
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P7 Obergruber Helmut
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – P7 Obergruber Helmut
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · P7 Obergruber Helmut
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · P7 Obergruber Helmut

Indicator parameters (4)

Indicator parameters – P7 Obergruber Helmut
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 0 KBE/100 ml 0/100 ml Single value · P7 Obergruber Helmut
Colony count 22 °C 3 KBE/ml 100 1/ml Single value · P7 Obergruber Helmut
Colony count 36 °C 1 KBE/ml 20 1/ml Single value · P7 Obergruber Helmut
Conductivity (25 °C) 217 µS/cm 2,500 µS/cm Single value · P7 Obergruber Helmut

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

PN-Stelle Hochbehälter Dirnsdorf

Marktgemeinde Kammern im Liesingtal

Assigned via the water supplier — the exact supply zone boundary within the postcode is not yet linked.

Key values PN-Stelle Hochbehälter Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · PN-Stelle Hochbehälter Dirnsdorf
Show all recorded parameters (6 — most recent value per parameter)

Microbiology (2)

Microbiology – PN-Stelle Hochbehälter Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Escherichia coli (E. coli) 0 KBE/100 ml 0/100 ml Single value · PN-Stelle Hochbehälter Dirnsdorf
Intestinal enterococci 0 KBE/100 ml 0/100 ml Single value · PN-Stelle Hochbehälter Dirnsdorf

Indicator parameters (4)

Indicator parameters – PN-Stelle Hochbehälter Dirnsdorf
Parameter Value Parametric value Share of the parametric value Reference
Coliform bacteria 1 KBE/100 ml 0/100 ml above the parametric value — this parameter must not be detectable Single value · PN-Stelle Hochbehälter Dirnsdorf
Colony count 22 °C 0 KBE/ml 100 1/ml Single value · PN-Stelle Hochbehälter Dirnsdorf
Colony count 36 °C 0 KBE/ml 20 1/ml Single value · PN-Stelle Hochbehälter Dirnsdorf
Conductivity (25 °C) 214 µS/cm 2,500 µS/cm Single value · PN-Stelle Hochbehälter Dirnsdorf

An exceedance of a parametric value does not automatically mean a health risk; the statutory parametric values include safety margins. Assessment and any measures are the responsibility of the competent health authority of the respective country.

Values taken unchanged from the publications linked below — for each parameter the most recent recorded value. „—" in the parametric value column: no currently valid legal parametric value is stored in our database for this parameter; the parameter register with all parametric values is being expanded continuously.

Source: https://www.kammern-liesingtal.gv.at/system/web/getDocument.ashx?cts=1780043579&fileid=1185290 · 22.05.2026 · Probenahme 07.05.2026, Prüfungszeitraum 08.05.2026 bis 18.05.2026 · retrieved on 14/08/2026

Frequent questions about postcode 8793

How hard is the water in Postcode 8793?
Marktgemeinde Kammern im Liesingtal publishes a total hardness of 1,25 mmol/l for the supply zone P2 Hochbehälter Seiz — that corresponds to 7 °dH. Hardness indicates how much calcium and magnesium are dissolved in the water. It is not a quality assessment: there is no parametric value for hardness. Basis: 22.05.2026, retrieved on 14/08/2026.
How much nitrate is in the drinking water in Postcode 8793?
Marktgemeinde Kammern im Liesingtal publishes a nitrate value of 5,1 mg/l for the supply zone P2 Hochbehälter Seiz. The statutory parametric value is 50 mg/l; the measured value represents 10 % of the parametric value. Basis: 22.05.2026, retrieved on 14/08/2026.
Who supplies the drinking water in Postcode 8793?
Marktgemeinde Kammern im Liesingtal. The values shown here come from the supply zone P2 Hochbehälter Seiz and apply to the water the supplier delivers. What happens between the building connection and the tap — in old lead pipes, for example — is not covered by these analyses; information on that is provided by owners, the health authority or an examination by an accredited laboratory.

General questions — how current the data is, limit of quantification, parametric values, who is behind this site — are answered under Questions & answers.